My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2925 RUCKER AVE 2021-12-17
>
Address Records
>
RUCKER AVE
>
2925
>
2925 RUCKER AVE 2021-12-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2021 3:53:21 PM
Creation date
12/17/2021 3:51:45 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2925
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
March 17, 2020 <br /> RE: Fire damages to 2925 and 2927 Rucker Ave <br /> Permit: F2001-001 <br /> Kurtis Brown, <br /> On January 21, 2020 I accompanied Ted De Budden on a walk-through to assess any <br /> potential problems with the plumbing/mechanical and electrical systems affected by the <br /> recent fire at 2925 Rucker Ave. <br /> I am concerned by the existing gas system. It appears to be interconnected between <br /> multiple tenant spaces. Please review the pictures in the above permit attachments. The <br /> meters are located in the 2927 Rucker Ave tenant space and appear to be manifolded <br /> together. <br /> IFGC: section 401.6 Interconnections. Where two or more meters are installed on the <br /> same premises but supply separate consumers, the piping systems shall not be <br /> interconnected on the outlet side of the meters. <br /> IFGC: section 401.7 Piping meter identification. Piping from multiple meter installations <br /> shall be marked with an approved permanent identification by the installer so that the <br /> piping system supplied by each meter is readily identifiable. <br /> Without these systems being identified and separated, we cannot isolate the gas service to <br /> a single tenant space nor can we determine proper sizing of each tenant space. <br /> I believe PSE should be notified so that they can inspect and correct any problems with <br /> the service side of these tenant spaces. I believe the gas service piping should be <br /> identified, separated and tested before allowing them back into service. <br /> In addition, we observed numerous electrical code issues and violations of tampering <br /> with the electrical systems <br /> We are requesting a fire safety inspection of these buildings, 2925-2929 Rucker Ave <br /> Respectfully, <br /> Shellie D Pons <br />
The URL can be used to link to this page
Your browser does not support the video tag.