• • <br /> 4. Provide details of construction for the new roof structure over the existing structure. Show <br /> how the new roof structure is attached to the existing structure and how it is resistant to <br /> uplift, overturning, gravity loads and exposure to the elements. <br /> 5. Show how the roof structure is ventilated. Provide ventilation calculations. Show location of <br /> ventilation openings in section and plan views. <br /> 6. Provide skirting around the perimeter of the proposed dwelling. Show access size and <br /> location and ventilation openings. <br /> 7. Insulation is required to be permanently supported at not more than 24 inches on center <br /> without compression. Show how insulation is supported. <br /> 8. Provide Guard per section R312 on both sides of the stairs. Provide detail of guard <br /> construction and attachment to the deck structure. Notching of the posts to attach deck <br /> joists requires calculations by a licensed engineer. <br /> 9. Provide minimum 36 inch landing at the bottom of all stairs. Show on plans. <br /> 10. Specify maximum 1-1/2" rise at exterior doors when door swings over exterior landing. <br /> 11. Show all support piers on the"SUPPORT PIER PLAN". <br /> Structural <br /> 1. It appears that an R=6.5 is being proposed for the design of the lateral force resisting <br /> system of the structure. However, the building's wall construction does not contain wood <br /> structural panels for lateral resistance. Please provide revisions to the lateral force resisting <br /> system or revise the R-factor for the appropriate construction of these walls indicated in <br /> A1.0. Please provide documentation indicating that the walls are rated for lateral <br /> resistance and are within acceptable limits of the demands calculated. See ASCE 7-10 <br /> Table 12.2-1. Revise base shear as required. <br /> 2. It appears in the design calculations that the design pressures used for wind checks are <br /> less than the minimum design pressures for walls and roof per Sec 27.1.5 of the ASCE 7- <br /> 10. Please revise these pressures and the affected base shear calculations. <br /> 3. Please provide the design bearing pressure used to check the foundations provided on the <br /> drawings. See IBC 2015 Sec 1603.1.6. Please include checks for shear and flexure of the <br /> footing's design. <br /> 4. Permanent foundations are required to have frost depth of 18"minimum from finished <br /> grade. It appears that these foundations are provided on-grade, please revise. <br /> agage 2 of 4 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-885/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.