WAC 296-46B-900: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii,iii,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> Ifir (a)Electrical plan review is not required for J:',k5pe...eti-th,i 0„,,, 9 ev% ctc.) <br /> EJ (i)Low voltage systems; <br /> 11-31 (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the projects distribution system <br /> o does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700,12(F); <br /> (B)An essential electrical system defined in NEC 517.2; or <br /> (C)A required fire pump system. <br /> (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> o rating of 9600 watts or less. <br /> (vil)For installations in(a)(ii),(iii),and(v)of this subsection to be considered,the following must be available <br /> to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed:and <br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical,dental, and chiropractic clinic"of which is a clinic or <br /> Edi physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> (b)Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> L-1 occupancies defined in this chapter. <br /> (c)If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900.1 <br /> Table 500-2 <br /> Health or Personal care Facilities <br /> Educational and Institutional Facilities,Places of Assembly.or Other Facilities <br /> Health or Personal Care Facility Pion Review <br /> Type Required Educational,Institutional,or Plan Review <br /> •Yoselal Yes Other Facility Types Required <br /> ties ng noire un,t icvleem Ediazatona 'es <br /> care.icpt ,mtitst,onal vf.7 <br /> Sms,mtq,nome IYet <br /> !! !tecvg fat I Ye! <br /> Dqvztethocnhosita' Ye l Notes to Tables 900-1 and 900-2, <br /> o.-wate ocythotr,c hopa Ye! A city authorized to do eiectfiCei rtspectitimi <br /> mate•mity i•iorrie Yes may regy,re pam ieview on fa ci type!tint <br /> Arrbtha•xfysurge,y`stmty Yet reviemeo uy tte depaftrrSni. <br /> F?4,16. ,-1.-er'ocflaysts ctr Y45 <br /> Res,oenval.,-63Vre-q facility Yes <br /> Pmanted sertice faziiity Yet <br /> wdt,t refiabMal)on Yet PERMIT# 0 C \, Page 2 of Cer <br />