My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12011 19TH AVE SE PARKING LOT 2021-12-23
>
Address Records
>
19TH AVE SE
>
12011
>
PARKING LOT
>
12011 19TH AVE SE PARKING LOT 2021-12-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2021 12:09:10 PM
Creation date
12/23/2021 12:07:51 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12011
Tenant Name
PARKING LOT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
No. 1 —Detention Ponds <br /> Maintenance Defect Conditions When Maintenance Is Results Expected When <br /> Component Needed Maintenance Is Performed <br /> Beaver Dams Dam results in change or function of Facility is returned to design function. <br /> the facility. (Coordinate trapping of beavers and <br /> removal of dams with appropriate <br /> permitting agencies) <br /> Insects When insects such as wasps and Insects destroyed or removed from site. <br /> hornets interfere with maintenance Apply insecticides in compliance with <br /> activities. adopted IPM policies <br /> Tree Growth Tree growth does not allow Trees do not hinder maintenance <br /> and Hazard maintenance access or interferes activities. Harvested trees should be <br /> Trees with maintenance activity(i.e.,slope recycled into mulch or other beneficial <br /> mowing,silt removal,vactoring,or uses(e.g., alders for firewood). <br /> equipment movements). If trees are Remove hazard Trees <br /> not interfering with access or <br /> maintenance,do not remove <br /> If dead, diseased,or dying trees are <br /> identified <br /> (Use a certified Arborist to determine <br /> health of tree or removal <br /> requirements) <br /> Side Slopes Erosion Eroded damage over 2 inches deep Slopes should be stabilized using <br /> of Pond where cause of damage is still appropriate erosion control measure(s); <br /> present or where there is potential for e.g., rock reinforcement, planting of <br /> continued erosion. grass, compaction. <br /> Any erosion observed on a If erosion is occurring on compacted <br /> compacted berm embankment. berms a licensed civil engineer should <br /> be consulted to resolve source of <br /> erosion. <br /> Storage Area Sediment Accumulated sediment that exceeds Sediment cleaned out to designed pond <br /> 10%of the designed pond depth shape and depth; pond reseeded if <br /> unless otherwise specified or affects necessary to control erosion. <br /> inletting or outletting condition of the <br /> facility. <br /> Liner(If Liner is visible and has more than Liner repaired or replaced. Liner is fully <br /> Applicable) three 1/4-inch holes in it. covered. <br /> Pond Berms Settlements Any part of berm which has settled 4 Dike is built back to the design <br /> (Dikes) inches lower than the design elevation. <br /> elevation. <br /> If settlement is apparent, measure <br /> berm to determine amount of <br /> settlement. <br /> Settling can be an indication of more <br /> severe problems with the berm or <br /> outlet works.A licensed civil engineer <br /> should be consulted to determine the <br /> source of the settlement. <br /> Piping Discernable water flow through pond Piping eliminated. Erosion potential <br /> berm. Ongoing erosion with potential resolved. <br /> for erosion to continue. <br /> (Recommend a Goethechnical <br /> engineer be called in to inspect and <br /> evaluate condition and recommend <br /> repair of condition. <br /> ['ohmic? I" Runoff Treatment BMPs—December 2014 <br /> 4-33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.