Laserfiche WebLink
BeamChek v2017licensed to:Duane Rowett/Design Lines Reg#2999-68383 <br /> Cornelsen Main Fir Bm <br /> B-01 Prepared by: KAD Date: 10/03/19 <br /> Selection 5-1/8x 15 GLB 24F-V4 DF/DF Lu =0.0 Ft <br /> Conditions NDS 2015 <br /> Min Bearing Area R1=8.7 in2 R2=8:1 in2 (1.5) DL Defl= 0.18 in Recom Camber=0.27 in <br /> Data Beam Span 17.5 ft Reaction 1 LL 4257# Reaction 2 LL 4073# <br /> Beam Wt per ft 18.68# Reaction 1 TL 5659# Reaction 2 TL 5291 # <br /> Bm Wt Included 327# Maximum V 5659# <br /> Max Moment 23575'# Max V(Reduced) 4917# <br /> TL Max Defl L/240 TL Actual Defl L/371 <br /> LL Max Defl L/360 LL Actual Defl L/545 <br /> Attributes Section (in3) Shear(in2) TL Defl (in) LL Defl <br /> Actual 192.19 76.88 0.57 0.39 <br /> Critical 118.36 30.73 0.88 0.58 <br /> Status OK OK OK OK <br /> Ratio 62% 40% 65% 66% <br /> Fb(psi) Fv(psi) E (psi x mil) Fc l (psi) <br /> Values Reference Values 2400 240 1.8 650 <br /> Adjusted Values 2390 240 1.8 650 <br /> Adjustments Cv Volume 0.996 <br /> Cd Duration 1.00 1.00 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:460 Uniform TL: 575 =A <br /> Point LL Point TL Distance <br /> 280 B=560 3.0 <br /> Uniform Load A <br /> Pt loads: <br /> 0 0 <br /> R1 =5659 R2=5291 <br /> SPAN = 17.5 FT <br /> Uniform and partial uniform loads are Ibs per lineal ft. <br />