My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
703 ALVERSON BLVD 2022-01-11
>
Address Records
>
ALVERSON BLVD
>
703
>
703 ALVERSON BLVD 2022-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2022 10:44:16 AM
Creation date
1/11/2022 10:43:51 AM
Metadata
Fields
Template:
Address Document
Street Name
ALVERSON BLVD
Street Number
703
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> SKALLEY <br /> Heating System Type: o All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature • <br /> Instructions — Design Temperature Difference(AT) 49 <br /> Everett <br /> t Paine AER AT=Indoor(70 degrees)-Outdoor Design Temp <br /> ■ F m <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 350 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 2,796 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions -- ----- ----- — <br /> se, u-v,n .� No selection --- <br /> �___,„�, ;ram ax _, <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions R<9 0.026 112 2.90 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions R 3R Vent. 0.027 238 6.43 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions (�Rdt nteived a 0.056 485 27.16 <br /> Floors U-Factor X Area UA <br /> Instructions R.,B- — 0.025 349 8.73 <br /> 6. <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 5P1en R-awe No selection 0 -- <br /> Slab Below Grade(see Figure 1) F-Factor X Le ngth UA <br /> Instructions No selection --- <br /> Slab on Grade(see Figure 1) F-Factor X Len ngth UA <br /> Instructions -----_----------- --- LJ,; klectRVzlee V No selection <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> C dtio ed Space <br /> cw - w x G 1.00 <br /> Sum of UA 45.21 <br /> Envelope Heat Load 2,215 Btu/Hour <br /> Figure 1. Sum of UAXAT <br /> _ Air Leakage Heat Load 1,480 Btu I Hour <br /> VolumeX 0.6X AT X.018 <br /> Above Grade Building Design Heat Load 3,695 Btu I Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 3,695 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 5,173 Btu I Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace 8 <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.