My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6107 BERKSHIRE DR T MOBILE ANTENNA 2022-01-11
>
Address Records
>
BERKSHIRE DR
>
6107
>
T MOBILE ANTENNA
>
6107 BERKSHIRE DR T MOBILE ANTENNA 2022-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2022 11:04:56 AM
Creation date
1/11/2022 11:04:17 AM
Metadata
Fields
Template:
Address Document
Street Name
BERKSHIRE DR
Street Number
6107
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RADIATOR DRAIN BLOCK HEATER NOTES <br /> CLIPPED TO FRAMERESTORE TO ORIGINAL CONDITION <br /> • <br /> / I THISP UNIT MUST 3 INSTALLED ACCORDANCE A WITH CURRENT <br /> T T\'Iobil e <br /> REMOVE COVER FOR '•s •--BATTERY DISCONNECT SWITCH APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL. ■ ■ ■ ■ ■ <br /> ACCESS TO RADIATOR / STATE.AND LOCAL CODES. <br /> FILL CAP(SECONDARY \ i I / 2.BATTERY(12 VOLT NEGATIVE GROUND SYSTEM). <br /> ACCESS PLATE BELOW) I JJ BATTERY 12V'GRP26 3.CONTROL PANEL:CIRCUIT BREAKER INFORMATION: ■ A! A ` ,'. 1A+� +aW <br /> �' NEGATIVE GROUND -MAiN LINE CIRCUIT BREAKER 125 AMPS , 1► x4 3 fir+► 4k <br /> \ PN:011483(NOTE 2) SEE SPECIFICATION SI-WET OR OWNERS MANUAL �` , '1+F*I• =PROJECT INFORMATION: <br /> -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. +II <br /> '' 1 3 f""` 4 REMOVE THE REAR STUB UP AND REAR ENCLOSURE COVER PANEL TO ACCESS o¢bao°. �o-a °° °,°, 0000°s <br /> I I.""•': THE STUB-UP AREAS AS FOLLOWS' ® L °gym o 0 00 °o?o i <br /> [ 1 •HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, o°° 000e°.• EVERETT MONOPOLE <br /> -NEUTRAL CONNECTION.AND BATTERY CHARGER 120 VOLT AC(0.5 AMP MAX)CONNECTION. o ° : °o°oo COMPACTED CLEAN <br /> t t F'/,. ; -LOW VOLTAGE CONNECTION INCLUDING TRANSFE4 SWITCH CONTROL WIRES. 30"MIN o°- ,- x °oa°°e' FILL MATERIAL SE01 603E <br /> F �/ ,� 5 CENTER OF GRAVITY AND WEIGHT MAY CHANGE DJE TO UNIT OPTIONS o°-*;•.;?-LJ;c:'� ,,a•:r o•Ooe <br /> r' 6 BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND on000 J",.3 '1 S^x(s o°°o°o <br /> _ RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW 1' 000'�,'j' 'r',;" ;�;'•o°o°000° WARNING TAPE W/TRACER WIRE 6107 BERKSHIRE DR <br /> 51 (2.41 / 7 REFERENCE OWNERS MANUAL FOR LIFTING WARNNGS. °°® 1'-4 o o` EVERETT WA 98203 <br /> r COG TBD R► l'A.:y„*. wi7o o°o r <br /> 8.MOUNTING BOLTS DR STUDS TO MOUNTING SURFACE SHALL BE SB41 GRADE 8 �`o;�,„' +'�'A:b L.°°off <br /> (USE STANDARD SAE TORQUE SPECS) ?. '-' <br /> COOLANT FILL-' 1„ 9 MUST ALLOW FREE FLOW OF INTAKE AIR DISCHARGE AIR AND EXHAUST SEE SPEC �'1,..,,,........!,�'' - COMPACTED SAND -ISSUED FOR. <br /> SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RES-RICTION REQUIREMENTS. 6"MIN - . <br /> OIL FILL -` IS GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE 3/4"(1"IF DISTANCE IS OVER 50') [REVISBUILDING PERMIT <br /> AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.RECOMMENDED MINIMUM PE PIPPING FOR LPG <br /> TOP VIEW PERIMETER(3FT)AND VERTICAL OVER EXHAUST(5FT)CLEARANCE FOR SITE LOCATION. NOTE: ION HISTORY:II.GENERATOR MUST BE GROUNDED. NONVEHICULAR AREAS:BACKFILL WITH CLEAN NATIVE CHIC <br /> RADIATOR/EXHAUST ;"""EXHAUST MUFFLER BACKFILL AND COMPACT TO 90%MAXIMUM DRY NO. DATE: DESCRIPTION: BY: <br /> DISCHARGE AIR i ENCLOSED WITHIN i ALARMED.LOCKING VICE ACTION DENSITY. VEHICULAR AREAS:BACKFILL WITH <br /> (NOTES 9 10) GENERATOR ENCLOSURE AIR INTAKE-,, LATCH ONE PER DOOR GRANULAR'A'AND COMPACT TO 95%MDD <br /> EACH SIDE 1 ONE UFT OFF DOOR PEP, <br /> il <br /> -893 (35 4)► . EMERGENCY STOP (NOTES 9,10) SIDE OF GENERATOR <br /> DOOR WIDTH 1133(44.6J f GAS LINE TRENCH DETAIL <br /> 1 TYP EMERGENCY CIRCUIT BREAKER4, <br /> SEE NOTE 3 / DIP STICK / 1 SCALE:NTS <br /> STOP s ;.�`. REAR ENCLOSURE -- <br /> SWITCH '1 /F�/ COVER PANEL 1 1 1 � AIR FILTER <br /> 1 '§ -.- ./ SEE(NOTE 4) <br /> :^ �,„ ! s I" '- J • AIR INTAKE I COOLANT 1359 [53.51 <br /> (NOTES 9.10) w^__.�- OVERFLOW OVERALL <br /> EIGHT <br /> .. . , MAIN LINE CIR28 CUIT 689 127.1] / • <br /> I• ^--CUSTOMER ACCESS BLOCK 7 i P � - OIL FILTER <br /> I <br /> 1 <br /> +:f 53.5 12.501 BREAKER HEIGHTHISH VOLTAGE .__ ASSEMBLY.CONTROL <br /> r. <br /> CONNECTION HEATER ,'j-Ai, _ I. <br /> LIFTING EYE t (NOTE } PANEL ACCESS t <br /> (4X) -- (NOTE 4) ---_ BATTERY CHARGER *e >j <br /> 50 (2.0) <br /> l LOCATED WITHIN <br /> SEE(NOTE 4) 863 [34 OJtA 58 ANCHOR NOTE: <br /> 46 11.8]--r-+--- 295 111.51 888 [350]�1I OIL DRAIN <br /> 3/4"NPTCOUPUNG - -..... 2139164,21 (2.31 1/2"KWIKBOLTTZW/3" <br /> + ( }- 1035 40.8-- LOW VOLTAGE OVERALL - <br /> STUB-UP WIDTH OVERALL.ENGTH EMBEDMENT AT EACH CORNER. _ n 10/5/2018 MINOR REV BJT <br /> FUEL LINE CONNECTION <br /> 3.'4"NPT FEMALE COUPLING INOTE4y <br /> RIGHT VIEW / \ 10/2/2018 ISSUED DESIGN REVIEW BJT <br /> +- 2026 179.81 REARVIEW <br /> UFTING =PLANS PREPARED BY: <br /> PFROVISIONS <br /> WEIGHT DATA: <br /> (NOTES 5.7 ANC CENTER <br /> OF GRAVITY DIMENSIONS) GENERATOR:TBD B. .I. THOMAS, P.E. <br /> GENERATOR WITH SHIPPING SKID:TBO GENERAC#RG025 25KW GAS GENERATOR <br /> LEFT MEW WEIGHT:KG(LBS) 7607 80TH AVE NE <br /> DIMENSIONS:MIA(INCHES) <br /> MARYSVILLE, WA 98270 <br /> NOTE 206-851.1106 <br /> / 0 13.5 X 29.5 STUB UP AREA FOR HIGH <br /> / 1017/32 X 1-3/321 AND LOW VOLTAGE CONNECTIONS =DRAWN BY: CHK.BY: <br /> /` MOUNTING SLOTS(4X) CIRCUIT BREAKER NEUTRAL AND <br /> / CUSTOMER CONNECTION OPENING, <br /> JL BJ <br /> 1 NOTE: =LICENSURE: <br /> COMPACTED BASE W/REINFORCING WIRE(TYP). <br /> l-I-UGH AND LOW 3000 PSI CONCRETE. T x o <br /> / STUB-UP AREA 786 NO SPECIAL INSPECTIONS REQUIRED. luF w�f�q,s <br /> / [30.91 • / ye <br /> / 125 <br /> 14 91 GROUND LEVEL � � � z <br /> { l T�(j <br /> 1:::;,, <br /> VA <br /> V 1 1/2"CHAMFER(TYP) A E•*a` <br /> #4 REBAR @ 12"O.C. ` <br /> 72 12 6[-. 51 [2.0 =DRAWING INFORMATION: <br /> I 1 38 11.51 EACH WAY BA WIRE MESH <br /> -A 125 14 9J 4"CONC PAD <br /> DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br /> FOR GENERATOR <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> -4 - - 1647 172.71 �� *A 274 110.6J ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> _ DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> TOP VIEW DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR <br /> 'I�%\l/\!/\//%l\�\!�\//�IJ\�/\/4 DISCLOSURE OTHER THAN WHICH IS RELATED TO FIRMED <br /> %1/\/\'\,�`�\'�'�\'�''`\,`,/'`'' CLIENT IS STRICTLY PROHIBITED. <br /> \\\-\\\\-\. \\ -DRAWING TITLE: <br /> __._.-850 13351 <br /> REMOVABLE STUB-UP ENERATCOVER--_OR , _ GENERATOR <br /> (SHIPPED LOOSE WITH GENERATOR DURING <br /> `' UNDISTURBED NATIVE SOIL DETAILS <br /> TO BE INSTALLED DURING <br /> 50 [2.0] nor=- 1971 1T1.6j -+4 25 (1.0}--1/4. - --838 133.01-.. --*" <br /> =DRAWING NUMBER: <br /> MOUNTING CENTERS ® GENERATOR PAD DETAIL <br /> SCALE:NTS <br /> � ___868 135 01 - <br /> A.2 <br /> END VIEW <br /> LEFT NEW <br /> LOIN <br />
The URL can be used to link to this page
Your browser does not support the video tag.