Laserfiche WebLink
ELECTRICAL NOTES: <br /> 1. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL 1\1.Eob ii e- <br /> CODE AND ANY LOCAL,CITY,OR COUNTY CODES THAT MAY APPLY. <br /> 2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. <br /> 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING,FILINGS,INSPECTIONS,AND TESTING AS REQUIRED BY THE =PROJECT INFORMATION: <br /> PERMITTING AUTHORITY AND T-MOBILE. <br /> 4. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT,SCHEDULE 40,TYPE 1,CONFORMING TO UL EVERETT MONOPOLE <br /> ARTICLE 651; MANUFACTURED BY WESTERN PLASTICS,CARLON,OR EQUAL.ALL BENDS SHALL BE 30"MINIMUM RADIUS. SEO160.3A <br /> 5. CONTRACTOR SHALL CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES.SERVICE LOCATIONS TO BE <br /> CONFIRMED PRIOR TO CONSTRUCTION. 6107 BERKSHIRE DR <br /> 6. ALL EQUIPMENT,WIRING,AND MATERIALS MUST HAVE A UL LABEL. <br /> EVERETT,WA 98203 <br /> 7. WIRES AND CABLES SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITH NO SPLICES ALLOWED. Ir—ISSUED FOR: <br /> 8. ALL JUNCTION AND OUTLET BOXES SHALL BE LABELED WITH KROY TAPE OR EQUAL.CONTRACTOR TO DESIGNATE ALL C BUILDING PERMIT <br /> CIRCUIT NUMBERS CONTAINED IN EACH BOX. _REVISION HISTORY: <br /> 9. CNN. <br /> THE DISTRIBUTION PANEL SHALL HAVE A TYPED LEGEND IDENTIFYING THE LOADS OF ALL CIRCUIT BREAKERS. NO. DATE: DESCRIPTION: NY: <br /> 10.CONTRACTOR SHALL INSTALL CONDUIT SEALING COMPOUND(BLACKBURN DX DUCT SEAL OR EQUAL)AFTER WIRING IS <br /> PULLED AND TERMINATED. <br /> (P)(3)#3/0 THWN W/(1)#4 GRN <br /> GRD IN 2"PVCCONDUIT laszals MINOR REV BJT <br /> (P)200 AMP 120/240V 10 <br /> 10/2/2018 ISSUED DESIGN REVIEW BJT <br /> AUTOMATIC TRANSFER SWITCH GENERATOR RECEPTACLE A <br /> (SERVICE RATED) WITHIN POWER CABINET =PLANS PREPARED BY: <br /> (P)200 AMP DISCONNECT <br /> (SERVICE RATED) (E)(E)200 AMP PANEL <br /> B.J. THOMAS, P.E. <br /> 7607 80TH AVE NE <br /> 200/2 L I MARYSVILLE, WA 98270 <br /> (E)200 AMP SERVICE METER l <br /> 206.851-1106 <br /> -/ - - 7- - -WALKING BEAM IATERLOCK <br /> 200/2 200/2 I -DRAWN BY: CHK.BY: <br /> (E)200 AMP METER BASE I I <br /> (P)(3)#3THWN IN 1-1/2"PVC CONDUIT I I JL BJ <br /> 100/2 sorz 2a1 201 <br /> (P)(3)#3 THWN W/(1)#8 GRN —LICENSURE: <br /> GRD IN 1-1/2"U/G PVC CONDUIT <br /> (P)(3)#3 THWN W/(1)#8 GRN © GROUND PER NEC ' o WAS1, <br /> GRD IN 1-1/2"U/G PVC CONDUIT A.'" <br /> 0 'c <br /> RECEPTACLE <br /> �, r o <br /> RECTIFIER LIGHT itir,"/ <br /> (P)GENERAC#RG025 25KW GENERATOR TRAY 1 <br /> ELECTRICAL ONE LINE =DRAWING INFORMATION: <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR <br /> DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED <br /> CLIENT IS STRICTLY PROHIBITED. <br /> —DRAWING TITLE: <br /> ELECTRICAL <br /> DETAILS <br /> DRAWING NUMBER: <br /> E. 1 <br /> _ _ __ ___ __ __ _ _ _ _ ___ <br /> 8 I6 <br />