My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4310 COLBY AVE SPRINT ANTENNA 2022-01-14
>
Address Records
>
COLBY AVE
>
4310
>
SPRINT ANTENNA
>
4310 COLBY AVE SPRINT ANTENNA 2022-01-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2022 8:08:47 AM
Creation date
1/11/2022 3:58:56 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4310
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-PLANS PREPARED FOR: <br /> _ ELECTRICAL SPECIFICATION: <br /> 1. COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE, THE REQUIREMENTS OF ALL APPLICABLE MUNICIPAL AND S ri n t STATE CODES AND REGULATIONS, AND UTILITY GUIDELINES. <br /> EXISTING 100A SERVICE <br /> 2. PERFORM ALL VERIFICATION, OBSERVATIONS, TESTING AND EXAMINATION OF WORK PRIOR TO THE ORDERING OF ELECTRICAL EQUIPMENT <br /> EXISTING UTILITY TRANSFORMER, 100A SERVICE FOR AND THE ACTUAL CONSTRUCTION. ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE CONSTRUCTION MANAGER LISTING ALL 15395 SE 30TH PL <br /> SPRINT. MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. BELLEVUE,WASHINGTON 98007 <br /> EXISTING SPRINT 100A, 240V, 3W UTILITY 3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40 CONFORMING TO UL ARTICLE 651: WESTERN <br /> METER 0 O PLASTICS OR CARBON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE <br /> -PLANS PREPARED BY: <br /> EXISTING 100A SERVICE __N'i1H PVC DUCT, ALL BENDS SHALL BE 30" MINIMUM RADIUS. I N F I N 1 G Y 8 <br /> 4. NEUTRAL SHALL BE COLOR CODED, INSULATION SHALL BE CROSS-LINKED POLYETHYLENE. <br /> NEW 100A RATED 2-POLE, 240V NEMA-3R SERVICE TOI N F I N I G Y <br /> \* VMAIN FUSED DISCONNECT SWITCH EQUIPPED WITH 5. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF FROM ZEROthe solu ns are endless <br /> 100A "RK1" FUSES. 6. UNDERGROUND SERVICES. SERVICE LOCATIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION. <br /> NOV (3) #1/0 AWG CU. AND (1) 5 AWG CU. GROUND IN 2" RMC A.F.G. AND RNC j • _L S 2500 W.HIGGINS RD.SUITE 510 <br /> 7. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING, AND FEES IN CONJUNCTION WITH THE PROJECT. HOFFMAN ESTATES,IL 60169 <br /> B.F.G. _ _ <br /> 8. THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH THE PROPER AUTHORITIES AND INFORM AT&T 24-HOURS IN JOB NUMBER 499-035 <br /> . ADVANCE. ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE WITHIN 24-HOURS AFTER <br /> NEW #4 AWG CU. GROUND ELECTRODE THE INSPECTION HAS TAKEN PLACE. -slrEAco: <br /> CONDUCTOR CONDED TO (2) 5/8" DIA. <br /> NEW SPRINT 100A RATED, NEMA-3R © \— X 1O'-O" LONG COPPER CLAD GROUND 9. ALL EQUIPMENT, WRING, AND MATERIALS MUST HAVE A UL LABEL • <br /> 120/240V 10-3W PPC CABINET. RODS SPACED A MIN. OF 6'-0" APART. <br /> CONTRACTOR TO REMOVE THE NEUTRAL 100A 100A 10. ALL WORK SHALL BE DONE BY LICENSED ELECTRICAL CONTRACTOR AND PERFORMED IN A WORKMANLIKE MANNER AND SHALL PROCEED IN sma rtl i n <br /> TO GROUND BOND INSIDE PPC. O tk <br /> � �� CAM-LOK RECEPTACLE MOUNTED TO PPC AN ORDERLY MANNER SO AS NOT TO HOLD UP THE PROGRESS OF THE PROJECT. <br /> IN FACTORY BY PANEL MANUFACTURER, <br /> DIRECTLY TO MAIN FUSE. 11. THOROUGHLY TEST ALL LINES, FEEDERS, EQUIPMENT, AND DEVICES WITH MAXIMUM LOADS TO ASSURE PROPER OPERATION 11410 NE 122ND WAY STE.102 <br /> WIREDKIRKLAND,WA 96034 <br /> 100A/2P <br /> A...____2��• 12. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES <br /> FACTORY INSTALLED CABLE. <br /> • 13. PROVIDE PULL BOXES WHERE SHOWN AND/OR WHERE REQUIRED BY CODES AND/OR UTILITY COMPANIES. -ENGINEERING LICENSE: <br /> 20A/2P • ~. 14. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS, CONTRACTOR SHALL . R.JQ <br /> 20A/1P it <br /> •� . <br /> • VERIFY ALL LOCATIONS. �.,�TOr.�RTAS, l,.�'�, <br /> • ~~ 15. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J—BOXES, EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC TAGS. �0 4 • 0 -"' <br /> NOTE: <br /> USE EXISTING 100 AMP METER SERVICE IF POSSIBLE. 16. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER. 1,(*) = FACTORY INSTALLED <br /> ALL OTHER CIRCUIT BREAKERS TO BE PROVIDED BY CONTRACTOR. 17. ALL FIRE RATED WALL AND FLOOR PENETRATIONS ARE TO BE CAULKED AND SEALED WITH A FIRE RESISTANT CAULKING TO MAINTAIN THE <br /> BASED ON PROVIDED INFORMATION. ELECTRICAL CONTRACTOR TO VERIFY. INTEGRITY OF THE FIRE SEPARATION. <br /> 18. UTILIZE SONNEBORN TYPE NP-1 CAULKING FOR SEALING ALL EXTERIOR WALL PENETRATIONS / • dr ,t6,398 i.,•� <br /> NONE <br /> S <br /> SINGLE LINE DIAGRAM (TYP) SCALE. 3 GENERAL ELECTRICAL NOTES SCALE: 2 �joNAL-f <br /> NONE <br /> 11-22-2019 <br /> DRAWING NOTICE: <br /> THESE DOCUMENTS ARE CONFIDENTIAL AND ARE <br /> THE SOLE PROPERTY OF SPRINT AND MAY NOT BE <br /> REPRODUCED,DISSEMINATED OR REDISTRIBUTED <br /> WITHOUT THE EXPRESS WRITTEN CONSENT OF, <br /> SPRINT. <br /> NEW PANEL "PP1" 100A, 120/240-10-3W, 60Hz, 100A M.C.B. <br /> BUS VA -REVISIONS: <br /> A BUS VA B LOAD WIRE GND COND. AMPS A BUS B AMPS COND. GND WIRE LOAD A B DESCRIPTION DATE BY REV <br /> 7000 7000 NEW ECAB CABINET #3 #8 0'-2" 100 1 4 _ _ _ _ SPACE <br /> SPACE <br /> - SPACE - - - - © - - - - SPACE - <br /> - SPACE - - - - 8 - - - - SPACE - <br /> 400 400 NEW BCAB CABINET #10 #10 0'-1" 20 9 12 _ _ _ SPACE REV.PER CTIYCO S7Et4Ts 1122/19 EPS <br /> SPACE V. SOw''" 9/5/19 EPS 2 <br /> 600 NEW WORK LIGHT #12 #12 0'-0 3/4" 20 ® - - - - SPACE - REV.PER EQUIPMENT LOCATION 701/19 EPR 1 <br /> - SPACE - - - - 16 - - - - SPACE - ISSUED FOR CONSTRUCTION 1129(18 EPA 0 <br /> - SPACE - - - - 0 - - - - SPACE - ISSUED FOR REVIEW 10/1/18 EPS A <br /> - SPACE - - - - 20 - - - - SPACE - r5T <br /> E NAME- SPACE - - - - ® - - - - SPACE - WESTERN MEDICAL <br /> - SPACE - - - - 24 - - - - SPACE - <br /> TOTAL VA: BUS A:8000 BUS B:17400 CONNECTED VA:15400 AMPERES:BUS A:7D BUS B:70 TOTAL:140 SPRINT SITE#: <br /> RATED VOLTAGE: 120/208 1 PHASE 3 WIRE BRANCH POLES:24 SE52XC206 <br /> RATED AMPS: 100 CABINET:ISURFACE <br /> FULL NEUTRAL BUS GROUND BUS HINGED DOOR ECLOSURE TYPE:NEMA-3R SITE ADDRESS: <br /> BRANCH DEVICES CIRCUIT BREAKER <br /> MAIN I 100A BREAKER 1 4310 COLBY AVE <br /> ALL NEW BREAKERS MUST MATCH&HAVE A MINIMUM AIC RATING OF 42,000 AMPS SYMETRICAL EVERETT',WA 98203-2338 <br /> NOTE: <br /> (*) = FACTORY INSTALLED SHEET DESCRIPTION: <br /> ALL OTHER CIRCUIT BREAKERS TO BE PROVIDED BY CONTRACTOR. <br /> BASED ON PROVIDED INFORMATION. ELECTRICAL CONTRACTOR TO VERIFY. ELECTRICAL PLAN <br /> SHEET NUMBER: <br /> SC <br /> AC PANEL SCHEDULES NONE <br /> 1 E-2 n 1r?., <br />
The URL can be used to link to this page
Your browser does not support the video tag.