Laserfiche WebLink
PLANS PREPARED FOR: <br /> I- <br /> Sprint GENERAL NOTES: STRUCTURAL WOOD NOTES: <br /> 1. THESE DOCUMENTS WERE DESIGNED IN ACCORDANCE WITH THE LATEST VERSION OF APPLICABLE 1. SPECIFICATIONS: <br /> LOCAL/STATE/COUNTY/CITY BUILDING CODES,AS WELL AS ANSI/TIA-222 STANDARD,AWWA-D100 A. WOOD CONSTRUCTION,UNLESS OTHERWISE NOTED,SHALL CONFORM TO THE"GENERAL CONSTRUCTION 6591 IRVINE CENTER DR.,SUITE 100 <br /> STANDARD,NOS,NEC,MSJC,AND/OR THE LATEST VERSION OF THE INTERNATIONAL BUILDING CODE, REQUIREMENTS",SECTION 2304 OF THE IBC 2012 AND THE NATIONAL DESIGN SPECIFICATION FOR WOOD IRVINE,CA 92618 <br /> UNLESS NOTED OTHERWISE IN THE CORRESPONDING STRUCTURAL REPORT. CONSTRUCTION. <br /> B. SHEATHING AND PANEL CONSTRUCTION UNLESS OTHERWISE NOTED SHALL CONFORM TO U.S.PRODUCT <br /> 2. ALL CONSTRUCTION METHODS SHOULD FOLLOW STANDARDS OF GOOD CONSTRUCTION PRACTICE. STANDARD PS-1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD AND APA DESIGN/CONSTRUCTION —PLANS PREPARED BY. <br /> GUIDE - RESIDENTIAL AND COMMERCIAL. EACH PANEL SHALL BE IDENTIFIED WITH AN APA GRADE I N FI N I GYM <br /> 3. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS TRADEMARK. <br /> EXPERIENCED IN SIMILAR CONSTRUCTION. 2. CONNECTIONS: <br /> A. ALL NAILING SHALL CONFORM TO TABLE 2304.9.1 "FASTENING SCHEDULE" OF THE INTERNATIONAL FROM ZERO TO I NF I N I GY <br /> 4. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS.IF OBSTRUCTIONS ARE FOUND,CONTRACTOR BUILDING CODE,UNLESS OTHER REQUIREMENTS NOTED ON THE DRAWINGS ARE MORE STRICT. the solutions we endless <br /> SHALL NOTIFY ENGINEER OF RECORD PRIOR TO CONTINUING WORK. B. WOOD STRUCTURAL PANEL FASTENERS SHALL BE 8D NAILS MINIMUM. ALL NAILS SHOULD BE COMMON <br /> WIRE NAILS UNLESS NOTED OTHERWISE. 26455 RANCHO PARKWAY SOUTH <br /> LAKE FOREST,CALIFORNIA 92630 <br /> 5. ANY CHANGES OR ADDITIONS MUST CONFORM TO THE REQUIREMENTS OF THESE NOTES AND C. JOISTS TO BEAMS OR JOISTS TO TRUSSES-16 GA.STD.JOIST HANGERS,UNLESS SHOWN <br /> SPECIFICATIONS,AND SHOULD BE SIMILAR TO THOSE SHOWN.ALL CHANGES OR ADDITIONS SHALL BE OTHERWISE. BEAMS TO BEAMS-16 GA.BEAM HANGERS, Jos#499-035 <br /> SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND/OR 3. MISCELLANEOUS:CONSTRUCTION. A. NON-LOAD BEARING HEADERS SHALL CONSIST OF THE FOLLOWING(U.N.O.): _SITE ACO: <br /> 0 TO 4'-0"OPENING (2)2 X 6 <br /> 6. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL MISCELLANEOUS SHORING, B. NO NOTCHING OF STUDS, JOISTS, RAFTERS, BEAMS, OR TRUSSES IS PERMITTED WITHOUT THE � � �t I <br /> BRACING,TEMPORARY SUPPORTS,ETC.NECESSARY TO PROVIDE A COMPLETE AND STABLE STRUCTURE ENGINEERS APPROVAL. HOLES BORED INTO THE STUD OR JOIST SHALL BE IN THE MIDDLE 1/3 OF THE <br /> DURING CONSTRUCTION.TIA-1019-A-2011 IS AN APPROPRIATE REFERENCE FOR THOSE DESIGNS MEETING TIA DEPTH,MIDDLE 1/3 OF THE SPAN,AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED) OF ��Ll <br /> STANDARDS.THE ENGINEER OF RECORD MAY PROVIDE FORMAL RIGGING PLANS AT THE REQUEST AND THE DEPTH. <br /> EXPENSE OF THE CONTRACTOR. C. VERIFY SIZE, NUMBER, AND LOCATION OF ALL MECHANICAL OPENINGS IN ROOF DECKS WITH 11410 NE 122ND WAY STE.102 <br /> MECHANICAL CONTRACTOR. KIRK(AND,WA9BD34 <br /> 7. INSTALLATION SHALL NOT INTERFERE NOR DENY ADEQUATE ACCESS TO OR FROM ANY EXISTING OR <br /> PROPOSED OPERATIONAL AND SAFETY EQUIPMENT. WOOD TRUSS NOTES: <br /> B. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO ANY FABRICATION.CONTACT INFINIGY MATERIALS: —ENGINEERING UCENSE: <br /> ENGINEERING IF ANY DISCREPANCIES EXIST. A. LUMBER: AS REQUIRED BY THE TRUSS MANUFACTURER. MINIMUM GRADE TO BE DF NO. 2 KO 15 <br /> PERCENT MC. <br /> STEEL CONSTRUCTION NOTES: B. CONNECTIONS: ALL INTERNAL TRUSS CONNECTIONS ARE TO BE DESIGNED BY THE TRUSS . <br /> MANUFACTURER. CONNECTORS SHALL BE DEFORMED PLATE TYPE,OF MINIMUM 20 GAUGE GALVANIZED .9w Ov WASI4 U,. <br /> 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION 14TH EDITION.FOR STEEL SHEET. ALL JOINTS ARE TO BE DESIGNED USING METHODS AS SET FORTH IN ANSI/TPI 1-2014: <br /> THE DESIGN AND FABRICATION OF STEEL COMPONENTS. NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. � d. C.A. <br /> C. HANGERS: ALL TRUSS TO TRUSS HANGERS SHALL BE MINIMUM 16 GA., AND SHALL BE PROVIDED /-: <br /> 2. ALL FIELD CUT SURFACES,FIELD DRILLED HOLES,AND GROUND SURFACES WHERE EXISTING PAINT OR BY THE TRUSS SUPPLIER. co `` <br /> GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIRED WITH(2)BRUSHED COATS OF ZRC D. ALL FASTENERS INCLUDING NAILS,ANCHOR BOLTS, POWDER ACTUATED FASTENERS,SCREWS,BOLTS, / <br /> • <br /> GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURERS'RECOMMENDATIONS. AND THREADED RODS, IN CONTACT WITH PRESSURE TREATED LUMBER ARE TO BE HOT DIPPED ;C f <br /> GALVANIZED PER ASTM A153 WITH A MINIMUM 6185 COATING OR STAINLESS STEEL WITH CHEMICAL *d 4XZIU" w <br /> 3. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BE STANDARD HOLES,AS COMPOSITION CONFORMING TO AISI 303/304 OR AISI 316. <br /> DEFINED BY AISC,UNLESS NOTED OTHERWISE. E. FASTENERS AND CONNECTORS ARE TO BE OF THE SAME MATERIAL, STAINLESS STEEL OR HOT Q ts��gysq <br /> �� 44 <br /> DIPPED GALVANIZED,DO NOT MIX MATERIALS. S-ZONAL <br /> 4. ALL EXTERIOR STEEL WORK SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A123. <br /> SPECIAL INSPECTIONS NOTES: <br /> 5. ALL STEEL MEMBERS AND CONNECTIONS SHALL MEET THE FOLLOWING GRADES: <br /> A. ANGLES,CHANNELS,PLATES AND BARS TO BE A36.FY=36 KSI,U.N.O. 1. A QUALIFIED INDEPENDENT TESTING LABORATORY,EMPLOYED BY THE OWNER AND APPROVED BY THE irW/7, 11-29-18 <br /> B. W SHAPES TO BE A992.FY=50 KSI,U.N.O. JURISDICTION,SHALL PERFORM INSPECTION AND TESTING IN ACCORDANCE WITH THE THE GOVERNING <br /> C. RECTANGULAR HSS TO BE A500,GRADE B.FY=46 KSI,U.N.O. BUILDING CODE,APPLICABLE SECTION(S)AS REQUIRED BY PROJECT SPECIFICATIONS FOR THE FOLLOWING DRAIMNG NOTICE: <br /> D. ROUND HSS TO BE A500,GRADE B.FY=42 KSI,U.N.D. CONSTRUCTION WORK: <br /> E. STEEL PIPE TO BE A53,GRADE B.FY=35 KSI,U.N.O. A. STRUCTURAL WELDING(CONTINUOUS INSPECTION OF FIELD WELDS ONLY). THESE DOCUMENTS ARE CONFIDENTIAL AND <br /> F. BOLTS TO BE A325-X.FU=120 KSI,U.N.O. B. HIGH STRENGTH BOLTS (PERIODIC INSPECTION OF A325 AND/DR A490 BOLTS) TO BE TIGHTENED PER ARE THE SOLE PROPERTY OF SPRINT AND MAY <br /> G. U-BOLTS AND LAG SCREWS TO BE A307 GR A.FU=60 KSI,U.N.O. "TURN-OF-THE-NUT"METHOD. NOT BE REPRODUCED,DISSEMINATED OR <br /> H. ANCHOR RODS TO BE A307 GR A.FU=60 KSI,U.N.O. C FIBER REINFORCED POLYMER. REDISTRIBUTED WITHOUT THE EXPRESS <br /> D. THE SPECIAL INSPECTOR MUST VERIFY THAT THE FRP MATERIAL SPECIFIED ON THE APPROVED WRITTEN CONSENT OF SPRINT. <br /> 6. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES,U.N.O. DESIGN DOCUMENTS IS BEING INSTALLED. <br /> E. THE SPECIAL INSPECTOR MUST VERIFY THAT ALL CUT EDGES AND DRILLED HOLES ARE PROPERLY <br /> 7. ALL WELDING SHALL CONFORM TO AISC AND AWS D1.1 LATEST EDITION. SEALED USING A VINYL ESTER SEALING KIT SUPPLIED BY THE MANUFACTURER. —REVISIONS: <br /> F. THE SPECIAL INSPECTOR MUST VERIFY THAT THE STRUCTURE IS BUILT IN ACCORDANCE WITH THE DESCRIPTION DATE BY REV <br /> 8. ALL HILT!ANCHORS TO BE CARBON STEEL,U.N.O. APPROVED DESIGN DOCUMENTS. FOR REV EW 1t/27/t6 OVA 0 <br /> MECHANICAL ANCHORS:KWIK BOLT-TZ,U.N.O. <br /> CMU BLOCK ANCHORS:ADHESIVE-HY120,U.N.O. 2. THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS TO THE BUILDING DEPARTMENT, REVISED CONNECTIONS 11/29/16 OVA 1 <br /> CONCRETE ANCHORS: ADHESIVE-HY150,U.N.O. THE ENGINEER OF RECORD,AND THE OWNER UNLESS THE FABRICATOR IS APPROVED BY THE BUILDING <br /> CONCRETE REBAR:ADHESIVE-RESOD,U.N.O. OFFICIAL TO PERFORM WORK WITHOUT THE SPECIAL INSPECTIONS. _ <br /> 9. ALL STUDS TO BE NELSON CAPACITOR DISCHARGE 1/4"-20 LOW CARBON STEEL COPPER-FLASH AT 55 KSI <br /> ULT/SO KSI YIELD,U.N.O. <br /> 10. BOLTS SHALL BE TIGHTENED TO A"SNUG TIGHT"CONDITION AS DEFINED BY AISC <br /> SITE NAME: <br /> 11. MINIMUM EDGE DISTANCES SHALL CONFORM TO AISC TABLE J3.4. <br /> WESTERN MEDICAL <br /> SPRINT SITE&: <br /> SE52XC206 <br /> SITE ADDRESS: <br /> 4310 COLBY AVE <br /> EVERET"T,WA 98203-2338 <br /> SHEET DESCRIPTION: <br /> GENERAL NOTES <br /> SHEET NUMBER: <br /> S-1 21)1 <br />