My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4310 COLBY AVE SPRINT ANTENNA 2022-01-14
>
Address Records
>
COLBY AVE
>
4310
>
SPRINT ANTENNA
>
4310 COLBY AVE SPRINT ANTENNA 2022-01-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2022 8:08:47 AM
Creation date
1/11/2022 3:58:56 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4310
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Structural Modification Analysis Report <br /> September 05,2019 <br /> Assumptions and Limitations <br /> Our structural calculations are completed assuming all information provided to Infinigy <br /> Engineering is accurate and applicable to this site. For the purposes of calculations, we assume <br /> an overall structure condition of"like new" and all members, connections, anchors, and masonry <br /> to be free of corrosion and/or structural defects. The structure owner and/or contractor shall <br /> verify the structure's condition prior to installation of any proposed equipment. If actual <br /> conditions differ from those described in this report Infinigy Engineering should be notified <br /> immediately to complete a revised evaluation. <br /> Our evaluation is completed using standard TIA, AISC, ACI, and ASCE methods and <br /> procedures. Our structural results are proprietary and should not be used by others as their own. <br /> Infinigy Engineering is not responsible for decisions made by others that are or are not based on <br /> our supplied assumptions and conclusions. <br /> This report is an evaluation of the rooftop mounted equipment and/or antenna supporting <br /> structures to be proposed or modified as shown in the referenced construction drawings. <br /> Applicable building element adequacy to support these structures is also evaluated when the <br /> applied forces increase significantly based on engineering judgment. <br /> The actual roof truss chord lumber grade is unknown and was assumed to be MSR lumber with <br /> E=1,800 ksi and Fb=2,600 ksi. If these assumptions are significantly different from present <br /> conditions,the result of this study must be re-evaluated. <br /> SE52XC206 Page 15 I 09.08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.