Laserfiche WebLink
Site Name: Western Medical <br /> Client: ATC INFINIGY Carrier: Sprint <br /> Engineer: DVA FROM ZERO TO INFINIGY <br /> Date: 9/5/2019 the solutions are endless <br /> INFINIGY WIND LOAD CALCULATOR 4.0.4 <br /> Site Information Inputs: Rooftop Inputs: <br /> Adopted Building Code: 2015 IBC Rooftop Wind Speed-Up?: No <br /> Structure Load Standard: ASCE 7-10 <br /> Antenna Load Standard: ASCE 7-10 <br /> Structure Risk Category: II <br /> Structure Type: Rooftop <br /> Number of Sectors: 3 <br /> Main Structure Shape: Round <br /> Wind Loading Inputs: Wind with No Ice Wind with Ice <br /> Design Wind Velocity: 110 mph(ultimate 3-second gust) q,(psf) Gh Fs,(psf) q,(psf) Gh Fs,(psf) <br /> Wind Centerline 1(zl): 46.5 ft 28.36 0.85 53.89 2.11 0.85 5.58 <br /> Side Face Angle(6): 60 degrees <br /> Exposure Category: C <br /> Topographic Category: 1 <br /> Ice Loading Inputs: <br /> Is Ice Loading Needed?: Yes <br /> Ice Wind Velocity: 30 mph(ultimate 3-second gust) <br /> Base Ice Thickness: 0.25 in <br /> Total Front Side q, EPA Fz Fx Fz(60) Fx(30) <br /> Appurtenances Elevation(ft) Ka <br /> Quantity Shape Shape (psf) (ft2) (Ibs) (Ibs) (Ibs) (Ibs) <br /> =S/CELWAVE APXVBBLL15X_43-C-I 46.5 3 1.00 Flat Flat 28.36 8.07 194.63 109.09 130.47 173.25 <br /> VG TELECOMMUNICATIONS M-Mlf 46.5 3 1.00 Flat Flat 28.36 6.79 163.61 53.95 81.36 136.19 <br /> NG TELECOMMUNICATIONS TME- 46.5 3 1.00 Flat Flat 28.36 2.74 65.94 43.13 48.83 60.24 <br /> SUNG TELECOMMUNICATIONS RF 46.5 3 1.00 Flat Flat 28.36 1.32 31.89 19.44 22.55 28.78 <br /> RFS/CELWAVE FIM800CAB-X 46.5 3 1.00 Flat Flat 28.36 1.22 29.47 16.48 19.73 26.22 <br />