My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1011 TEMPLE DR 2022-01-13
>
Address Records
>
TEMPLE DR
>
1011
>
1011 TEMPLE DR 2022-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2022 8:19:00 AM
Creation date
1/13/2022 8:18:04 AM
Metadata
Fields
Template:
Address Document
Street Name
TEMPLE DR
Street Number
1011
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> i <br /> A PROJECT NO. SHEET NO. <br /> �'�.0 S201123-4XR <br /> ice` � <br /> ��� 1011 Temple Dr, Everett, WA 98201 <br /> PROJECT P <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY ZT 1/18/2021 <br /> ENGINEERING&DESIGN BY DATE <br /> Ideal Foundation Systems 2-71816 Helical Pile(0,203-huts wall thickness)-Soil Capacity per ESR 3250 <br /> DIGGA 10K Drive Torque, Torque Correlation Factor, Ultimate Axial Compressive Capacity, Allowable Axial Compressive Capacity, <br /> Head Pressure I Kt(Compressionj P•=VT Px=0.5*P._ <br /> (psi) 1/f^lbs) (ft t) #laps) (kips) <br /> 500 1740 9 15.7 7.8 <br /> 600 2,088 9 18.8 9.4 <br /> 700 2,436 9 21.9 11.0 <br /> 800 2,784 9 25.1 12.5 <br /> 900 3,132 9 28.2 14.1 <br /> 1000 3,480 9 31.3 15.7 <br /> 1100 3,828 9 34.5 17.2 <br /> 1200 4,176 9 37.6 18.8 <br /> 1300 4;524 9 40.7 20.4 <br /> 1400. 4,872 9 43.8 21.9 <br /> 1500 5,220 9 47.0 235 <br /> 1600 5,568 9 50.1 251 <br /> 1700 5,916 9 53,2 26.6` <br /> 1800 6,264 9 56.4 28.2, <br /> 1900 6,612 9' 59.5 29.8 •See Note vdi< <br /> 2000 6,960 9 62.6 31.3 <br /> 2100 7,308 9 65.8 329 <br /> 2200 7,656 9 68.9 34.5 <br /> 2300 8,004 9 72.0 36.0 <br /> 2385 8,300 9 74.7 37.3 •See Note ii. <br /> i.)DIGGA 10K Drive Head.differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii:)Per Table 5A of FSR-3750 and Ideal Manufacturing Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,300 <br /> ft•lbs.Final installation torque shall not exceed this value: <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed lathe structural <br /> package,but shall not exceed the maximum allowable capacity for any part of the pile assembly_ <br /> iv.)Refer to ESR-3750 and ideal Manufacturing,Inc,documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in Willis;the last torque reading taken during pile installation,using;for example,the torque reading <br /> instruments connected to the installation equipment. <br /> xe Torque correlation factor per€SR-3750 <br /> P..s Ultimate axial compressive capacity(in kips)of helical pile <br /> P.=Allowable axial compressive capacity(in kips)of helical pile <br /> vi:)For torque readings between those listed,use the following equation to determine the allowable capacity:P.=(I*l0/2' <br /> vii.)1 kip=1;000lbs <br /> val.)Per Note 3 of ideal Group Dvag No.:278TFG dated 4/23/20 the ultimate structural capacity for the 7/8"TRU-FORCE Underpinning'Bracket is limited to <br /> 60 kips. <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.