. A I B I C I D I E I F I G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> -g ,� a ^,, , , �" 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> } ,: , , . " DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ' ;j. < ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> ' • SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> 4 w g t' :- THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> ¢' � 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS& RULES OF THE <br /> {;, THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> _ R --,- BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. — <br /> (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> �_> - . . x`_ 14- LABORATORY SHALL LIST ALL OF WORK. <br /> .A '" =' EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> N "' 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> Atrii' STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> .< INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> V t. .. '*" Wit, - 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> = AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> ` BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> — <br /> A UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 4 6. MODULE FRAMES, RAIL,AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> __'` � SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> �' F 7 <br /> GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> :. 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. c, <br /> co CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> 9. ALL ELECTRICAL WORK TO BE IN <br /> COMPLIANCE WITH THE NATIONAL <br /> — ELECTRIC CODE (NEC). — <br /> I <br /> rs <br /> "ys = SHEET INDEX C PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> : •f PV 2 SITE PLAN PV 6 PLACARD cn <br /> ` - r�w <br /> r �4 PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> ••e° CONFIDENTIAL-THE INFORMATION CONTAINED CUSTOM <br /> °o•�.. • IN THIS PACKET AND SUBSEQUENT CUTSHEETS Christopher Casey JWN DESIGN <br /> •6*e.�i••• SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER DATE: <br /> ••o•:••° ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 4/27/2020 <br /> •• ••. SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 <br /> •••1jii . p 0 w E R TI , PT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 4807 Wilmington Ave, Everett, WA 98203% PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN <br /> PV 1 <br /> CONSENT FROM SOLGEN POWER. 8\273 <br />