Laserfiche WebLink
S • <br /> Krueger Krafting <br /> 22901 58th Ave.W,Mountlake Terrace,WA 98043 <br /> 206-819-2710 greg@kruegerkrafting.com <br /> City of Everett 2-27-2020 <br /> In reference to your corrections record #B2002-012-1715 Rainier Ave. <br /> Hello City of Kirk1ancYstaff, <br /> The following items are in response to your letter dated: 02-25-2020 <br /> Please see revision Delta 1 on the drawings: <br /> Building Department Comments: <br /> 1. Closet that enclosed the electrical panel has been removed. <br /> 2. Stair section provided with stair calculation. <br /> 3. Code reference section has been noted to R311.7.5.3. <br /> 4. Handrail section R311.7.8 noted and handrails drawn and noted for height on the plans. <br /> 5. Fire blocking under stairs noted on detail 1/A1. <br /> 6. Studs at the upper floor half wall now shown as full ht. studs from basement floor to top of <br /> half wall. <br /> 7. Stair section provided in the drawing with the stair calculation.The discrepancy of how <br /> many stairs on each drawing has been clarified. <br /> 8. The fire blocking in this instance was referring to the application when you have open <br /> web floor joists and the area in the floor exceeds 1,000 sq. ft. and with solid saw joists <br /> this would not apply. I was previously confused about why this was being asked for <br /> and it has now been clarified.This note has been removed as it is moot and the fire <br /> blocking in question has been provided at detail 4/D1. The detail reference on the plans <br /> has been corrected as well. <br /> 9. New note #10 identifying draft stop blocking per section R301.12 <br /> Please let me know if you have any additional questions. <br /> Greg Krueger <br />