Laserfiche WebLink
THE GRAND CkONDC)MINIUMS <br />GENERAL ARCHITECTURAL NOTES: Everett, Washington <br />1. VERIFY ALL DIMENSIONS AT THE SITE BEFORE STARTING WORK <br />2. COMPLY WITH ALL LOCAL CODES AND ORDINANCES. <br />3. VERIFY LOCATION AND DISPOSITION OF UTILITIES. <br />4. REVIEW ALL PLANS AND SPECIFICATIONS AND PROVIDE ALL OPENINGS REQUIRED BY OTHER TRADES. <br />5. ALL DIMENSIONS SHOWN ON DRAWINGS ARE TAKEN FROM ORIGINAL CONSTRUCTION DOCUMENTS UNLESS NOTED OTHERWISE, <br />U.N.O. AS SUCH, FIELD VERIFY ALL DIMENSIONS PRIOR TO START OF WORK <br />6. ALL WORK AND MATERIALS SHALL MEET THE STANDARDS AND SPECIFICATIONS OF THE CITY OF EVERETT ADOPTED CODES AND <br />AMENDMENTS TO THE CODES. <br />7. THE CONTRACTOR SHALL APPLY AND SECURE ALL OCCUPANCY, SEWER, STORM WATER, ELECTRICAL, MECHANICAL AND OTHER <br />PERMITS REQUIRED, AND THE CONTRACTOR SHALL PAY ALL NECESSARY FEES AND POST BONDS AS REQUIRED. <br />8. POUR NO CONCRETE WHEN THE ANTIGPATED SITE TEMPERATURE WILL BE BELOW 34 DEGREES FAHRENHEIT DURING THE <br />FIRST 48 HOURS OF CURING. <br />9. WORKING HOURS FOR THE USE OF LOUD EQUIPMENT SHALL BE LIMITED TO TIMES ESTABLISHED BY CITY OF EVERETT AUTHORITY. <br />THIS EQUIPMENT SHALL INCLUDE BUT IS NOT LIMITED TO COMPRESSORS, GRADERS, DRILLS, COMPACTORS, RADIOS, AND OTHER <br />SIMILAR EQUIPMENT. RADIOS, CD PLAYERS, BOOM BOXES, ETC. SHALL NOT BE PLAYED WHERE THEY WILL CAUSE DISTURBANCE <br />TO TENANTS. <br />10. THE INTENT OF THE DRAWINGS IS TO SHOW GENERAL SCOPE AND INTENT OF THE WORK METHODS AND MATERIALS NOT <br />EXPLICITLY IMPLIED ARE INTENDED TO BE BUILDER DESIGNED. PROVIDE SUBMITTALS FOR APPROVAL WHERE SPECIFICALLY <br />REQUESTED IN THE CONSTRUCTION DOCUMENTS AND AS SPECIFIED. WRITTEN DIMENSIONS ON THE DRAWINGS SHALL HAVE <br />PRECEDENCE OVER SCALED DIMENSIONS (SEE NOTE 5). CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC., <br />PERTAINING TO THE WORK BEFORE PROCEEDING. THE ARCHITECTS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM <br />THE DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DOCUMENTS. ANY SUCH VARIATIONS SHALL BE RESOLVED BY THE <br />ARCHITECTS OFFICE PRIOR TO PROCEEDING WITH THE WORK, OR THE CONTRACTOR SHALL ACCEPT FULL RESPONSIBILITY FOR <br />COST TO RECTIFY SAME. <br />11. CONTRACTOR SHALL VERIFY ALL ELEVATIONS PRIOR TO COMMENCEMENT OF WORK. DISCREPANCIES FOUND IN THE FIELD <br />SHALL BE RESOLVED AS INDICATED IN THE PRECEDING NOTE. <br />12. CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION BRACING, SHORING, AND TENTING DURING CONSTRUCTION. <br />13. FEATURES NOT FULLY SHOWN ON PLANS OR DETAILS ARE TO BE PROVIDED AS SPECIFIED FOR SIMILAR CONDITIONS. <br />14. ALL WORK REQUIRED SHALL BE PROVIDED, INSTALLED COMPLETE AND IN OPERATING CONDITION. <br />15. QUALITY OF MATERIALS AS SPECIFIED SHALL BE CONSIDERED MINIMUM AND ANY CHANGE SHALL BE OF DEMONSTRATED BETTER <br />QUALITY UNLESS SPECIFICALLY RELEASED BY OWNER (OR OWNER'S AGENT AND APPROVED BY THE BUILDING DEPARTMENT. <br />MATERIALS NOT SPECIFIED SHALL BE OF A HIGH QUALITY INTENDED FOR RESIDENTIAL USE. PROVIDE ADEQUATE HEAT AND SHELTER <br />FOR MATERIAL PRIOR TO, AND DURING EXECUTION OF THE WORK, AND UNTIL OWNER ACCEPTANCE, TO MAINTAIN DIMENSIONAL <br />STABILITY AND MATERIAL QUALITY. MATERIALS AT INSTALLATION SHALL BE OF A MOISTURE CONTENT THAT WILL NOT ALTER GENERAL <br />APPEARANCE OR INTEGRITY OF ASSEMBLY WHEN MOISTURE CONTENT DECREASES TO SERVICEABLE LEVELS. MATERIALS ARE TO BE <br />INSTALLED IN A PROFESSIONAL MANNER TO THE HIGHEST INDUSTRY STANDARDS, ALL PARTS TO BE COMPLETE AND OPERATIONAL <br />16. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO AVOID INTERFERENCE BETWEEN DIVISIONS OF THE <br />WORK WHERE INSTALLATION AND/OR CONNECTION OF EQUIPMENT IS NOT SPECIFIED AND WHERE SUCH CONNECTION AND/OR <br />INSTALLATION IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR SUCH <br />CONNECTION AND/OR INSTALLATION. THIS WORK SHALL INCLUDE ALL UTILITY HOOKUPS INCLUDING THE COST TO ENERGIZE THE <br />ELECTRICAL SYSTEM BY LOCAL UTILITY COMPANY. <br />17. CONTRACTOR TO REMOVE ALL MATERIALS NOT RELATED TO THE FINISHED PRODUCT FROM THE SITE, (DO NOT BURY ON SITE). <br />PROJECT UNDER CONTRACTUAL SUPERVISION SHALL HAVE A PUNCH LIST PREPARED BY THE ARCHITECT WHICH IS TO BE FULLY <br />EXECUTED PRIOR TO FINAL PAYMENT. <br />SCOPE OF WORK: <br />C U <br />U <br />N <br />L- p Cz <br />O <br />Q <br />�•��� <br />U) <br />CD <br />�Q�Uao <br />4-��(v�a� <br />L C a--r Q Q <br />6 In <br />-_ <br />W <br />VJ <br />O O U Q <br />0 0- <br />d <br />o +-r (on (U <br />_ <br />`0- <br />O <br />N <br />a) <br />L-1- CY) <br />-M <br />= <br />= <br />) L >. <br />CZ c <br />M�a <br />J- <br />Q a <br />ZO <br />Ctf <br />_ <br />LO <br />cn U=> <br />U <br />(Do <br />o <br />va <br />Q)Q:t�c <br />-, <br />U7 <br />O <br />Cn <br />0-0- O U o <br />U) (D <br />C_ •- <br />LU <br />U <br />4-(D <br />p <br />M <br />LL, <br />N U L > <br />0 a <br />O <br />p <br />L <br />(Y) <br />/� <br />M <br />0) LL <br />O O <br />-1-x <br />Q <br />O <br />n U '- <br />(n C� <br />+- <br />LL <br />O <br />X (u _ <br />C� <br />a-) <br />(1)(1)0) <br />Ca <br />CT <br />TD <br />N <br />O <br />O <br />2 <br />cn <br />LU E> o (n <br />22 <br />(z m- <br />a) -a <br />LLJ <br />0- <br />0 <br />0- <br />Work to be performed under this permit/contract involves repair work <br />necessary due to Issues with the buildings original construction. Areas that <br />will fail under the scope of this work are included in the following list: ;Refer to <br />Project Manual for additional requirements). <br />> Improved drainage of exterior deck areas as directed <br />> Provide new waterproof traffic surface on all decks as directed. <br />> Remove some or all of existing siding and replace as directed. <br />> Repair, replace, or provide shear wall panels as directed. <br />> Remove existing and construct new walkway bridge between <br />buildings 1 and 2. <br />Make Improvements to existing drainage in elevator lobby areas on each <br />floor as directed. <br />Install new and/or repair existing windows and doors as directed. <br />> Repair, replace, and/or provide (lashings and counter flashings In ell areas <br />to provide a watertight structure. Including; column bases, window/door <br />penetrations deck edges, utility penetrations <br />> Provide necessary means to bring all stair towers to current code requirements. <br />Inspect and repair all utility dosets (furnace & water heater spaces) to <br />correct problems associated with water leakage. This Includes cesmgs <br />from problems on level above. <br />> Provide water heater drip pans at all units that continue to use tank type <br />water heating systems. <br />> Inspect and provide fire taping, fire stopping, and fire shaft assembles for <br />utlllty closet shafts from the 2nd (first level of dwelling units) through to <br />underside If roof sheathing. <br />> Provide fire taping, GWB repairs, and fire -stopping of all dlmising partitions In <br />attic space to achieve rated assembly required (one or two hour). <br />> Provide work as directed for all seismic hold down hardware and assemblies <br />that we accessible from exterior of buildings, Including incidental Interior work <br />scheduled herein. <br />> Replace existing guardrails as directed herein after removal during deck work. <br />Areas that do not receive deck work will still require that handrails be removed <br />and reinstalled as directed. <br />> Repair/replace existing gutters for positive drainage. <br />> Construct arbors at level 2 where shown on drawings. Route downspouts <br />as shown on arbor details. <br />> Replace lighting In elevator lobbies In each building, on each floor as directed. <br />APPLICABLE CODES & REFERENCES: <br />Automatic Fire Detection & Suppression Systems Ordinance No. 1902-92 <br />International Building Code (IBC), 2006 Edition & WAG 51-50 <br />Accessible and Usable Buildings & Facilities, ANSI At 17.1-2003 & <br />WAG 51-50-005 <br />International Fire Code (IFC), 2006 Edition & WAG 51.54 <br />International Mechanical Code (IMC), 2006 Edition & WAG 51-52 <br />National Electrical Code (NEC), 2005 Edition & WAG 296-46B-010 <br />Uniform Plumbing Code (UPC), 2006 Edition & WAG 51-56 & 51-67 <br />Washington State Energy Code (WSEC), 20GS Edition, WAG 51-11 <br />Washington State Ventilation & Indoor Air Quality Code (VIAO), 2006 <br />Edition, WAG 51-13 <br />City of Everett Design & Construction Standards & Specifications <br />Everett Stormwater Management Manual <br />LEGAL DESCRIPTION: <br />LOTS 1 - 7, INCLUSIVE, BLOCK 10 FRIDAYS SECOND ADDITION TO <br />THE CITY OF EVERETT ACCORDING TO THE PLAT THEREOF <br />RECORDED IN VOLUME 3 OF PLATS, PAGE 56, RECORDS OF <br />SNOHOMISH COUNTY, WASHINGTON. TOGETHER WITH A 10 FOOT <br />STRIP OF LAND ADJOINING LOTS 4 AND 5 OF SAID PLAT <br />ACCUIRED THROUGH THE VACATION OF A PORTION OF GRAND <br />AVENUE BY THE CITY OF EVERETT UNDER VACATION ORDER <br />#2555. EXCEPT THE EAST 12.9 FEET OF LOT 1 OF SAID PLAT OF <br />FRIDAY'S SECOND ADDITION GRANTED FOR USE AS A PUBLIC <br />ALLEY OR HIGHWAY BE DEED RECORDED UNDER VOLUME 62 OF <br />DEEDS, PAGE 274, RECORDS OF SNOHOMISH COUNTY. SITUATED <br />IN SNOHOMISH COUNTY, WASHINGTON. CONTAINING 2.88 ACRES <br />MORE OR LESS. <br />GENERAL INFORMATION: <br />Project Address <br />1318 37th Street <br />Everett, WA <br />Zone R-4 <br />Parcel Number 00908900xxxx00 <br />Parcel number's vary for each unit on site. The'x's would be replaced <br />by each unit number <br />Current use is privately owned condominium units (total of 90 units) <br />Including a 4,400 SF community/recreatioln center <br />No net added bu8ding area proposed <br />No changes to parking proposed <br />No change to lot coverage proposed <br />Occupancy Group Per IBC Sec 304 R-1 Residential & S-2 (Parking) <br />Construction Type Per IBC Table 503 V-1 HR <br />Occupancy Load per IBC Table 1004.1.2 Group R - 200 (Fir Area/Occupant) <br />No work proposed In parking level Group S2 - 200 <br />No change In use proposed Residential Units <br />No change in fire protection Fully Sprinkled Building Per USC/UFC <br />current at time of construction <br />Separate Permits Mechanical, Plumbing, & Electrical Work <br />incidental to specified scope <br />Required Special Inspections Shear Walls (Type SW#), Ind. Holed - <br />OWNERS: ARCHITECT: STRUCTURAL ENGINEER: <br />Grand Condominium Grace Architects, PLLC Swenson Say Faget, Seattle <br />Home Owners Association 1927 Post Alley 2124 3rd Avenue <br />1318 37th Street Seattle, WA 98101 SEATTLE, WA 98121 <br />Everett, WA 98201 Tel: 206 957-9800 Tel: 206 443-6212 <br />Fax: 206 682-3159 FAX: 206 443-4870 <br />SHEET INDEX: <br />AO.0 SITE PLAN & PROJECT INFO <br />A0.1 SITE MAP & BLDG PLAN (FOR REFERENCE ONLY) <br />A0.2 ORIGINAL PLAN FOR SHEAR WALL DESIGN <br />(FOR REFERENCE ONLY) <br />A1.1 PARKING (1 ST) LEVEL PLAN BUILDING I <br />A7.2 2ND LEVEL FLOOR PLAN BUILDING I <br />A1.3 3RD LEVEL FLOOR PLAN BUILDING 1 <br />AI A 4TH LEVEL FLOOR PLAN BUILDING I <br />A1.5 STH LEVEL FLOOR PLAN BUILDING I <br />AI.6 ROOF LAYOUT PLAN BUILDING I <br />A1.7 N - S ELEVATIONS BUILDING I <br />A1.8 E- W & ENTRY TOWER ELEVATIONS BUILDING I <br />A1.9 SECTIONS BUILDING 1 <br />A21 PARKING (1ST) LEVEL PLAN BUILDING 11 <br />A22 2ND LEVEL FLOOR PLAN BUILDING 11 <br />A23 3RD LEVEL FLOOR PLAN BUILDING 11 <br />A24 4TH LEVEL FLOOR PLAN BUILDING 11 <br />A25 STH LEVEL FLOOR PLAN BUILDING 11 <br />A2.6 ROOF LAYOUT PLAN BUILDING II <br />A2.7 N - S ELEVATIONS BUILDING 11 <br />A28 E - W & ENTRY TOWER ELEVATIONS BUILDING 11 <br />A29 SECTIONS BUILDING it <br />A210 BRIDGE ELEVATIONS & ARBOR ENLARGED PLAN <br />A3.1 PARKING (1ST) LEVEL PLAN BUILDING III <br />A3.2 2ND LEVEL FLOOR PLAN BUILDING III <br />A3.3 3RD LEVEL FLOOR PLAN BUILDING III <br />A3.4 4TH LEVEL FLOOR PLAN BUILDING III <br />A3.5 STH LEVEL FLOOR PLAN BUILDING III <br />A3.6 ROOF LAYOUT PLAN BUILDING III <br />A3.7 N - S ELEVATIONS BUILDING III <br />A3.8 E - W & ENTRY TOWER ELEVATIONS BUILDING III <br />A3.9 SECTIONS BUILDING III <br />A4.1 RECREATION CENTER DRAWINGS <br />A5.1 DETAILS <br />A5.2 DETAILS <br />A5.3 DETAILS <br />A5.4 ARBOR DETAILS & SECTIONS <br />seem e,mvtse k,,..et,g W x mpa Tt ne]v. <br />�AR(}!S I�mCi <br />1 SIA/IE � GNAW nM <br />CONDOMINIUM RENOVATION <br />GRAND CONDOMINIUMS <br />EVERETT, WA <br />SITE PLAN & PROJ. INFORMATION <br />Project N. 7027 <br />an.e Nr djw <br />rota 10-23-2007 <br />ISSLID <br />tavmaN <br />SFret Na <br />A0.0 <br />