My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 37TH ST 2023-06-14
>
Address Records
>
37TH ST
>
1318
>
1318 37TH ST 2023-06-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2023 9:31:46 AM
Creation date
1/24/2022 9:19:40 AM
Metadata
Fields
Template:
Address Document
Street Name
37TH ST
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />GAS PIPING INSTALLATIONS <br />TABLE 409.1.1 <br />MANUAL GAS VALVE STANDARDS <br />VALVE STANDARDS <br />APPLIANCE SHUTOFF <br />VALVE APPLICATION UP <br />To PRESSURE <br />OTHER VALVE APPLICATIONS <br />UP TO PRESSURE <br />UP TO 2 psig <br />PRESSURE <br />UP TO 5 psig <br />PRESSURE <br />UP TO 125 psig <br />PRESSURE <br />ANSI Z21.15 <br />X <br />— <br />- <br />— <br />— <br />ASME B16.44 <br />X <br />X <br />V <br />Xb <br />— <br />ASME B16.33 <br />X <br />X <br />X <br />X <br />X <br />For SI: 1 pound per square inch gauge = 6.895 kPa. <br />a. If labeled 2G: <br />b. If labeled 5G. <br />valves shall be provided for each tenant. Each tenant shall <br />have access to the shutoff valve serving that tenant's <br />space. <br />409.3.2 Individual buildings. In a common system serv- <br />ing more than one building, shutoff valves shall be <br />installed outdoors at each building. <br />409.3.3 Identification of shutoff valves. Each house line <br />shutoff_ valve shall be plainly marked with an identifica- <br />tion tag attached by the installer so that the piping systems <br />supplied by such valves are readily identified. <br />409.4 MP regulator valves. A listed shutoff valve shall be <br />installed immediately ahead of each MP regulator. <br />409.5 Appliance shutoff valve. Each appliance shall be pro- <br />vided with a shutoff valve in accordance with Section <br />409.5.1, 409.5.2 or 409.5.3. <br />409.5.1 Located within same room. The shutoff valve <br />shall be located in the same room as the appliance. The <br />shutoff valve shall be within 6 feet (1829 mm) of the <br />appliance, and shall be installed upstream of the union, <br />connector or quick disconnect device.it serves. Such shut- <br />off valves shall be provided with access. Appliance shut- <br />off valves located in the firebox of a fireplace shall be <br />installed in accordance with the appliance manufacturer's <br />instructions. <br />409.5.2 Vented decorative appliances and room heat- <br />ers. Shutoff valves for vented decorative appliances, room <br />heaters and decorative appliances for installation in vented <br />fireplaces shall be permitted to be installed in an area <br />remote from the appliances where such valves are pro- <br />vided with ready access. Such valves shall be permanently <br />identified and shall not serve another appliance. The pip- <br />ing from the shutoff valve to within 6 feet (1829 mm) of <br />the appliance shall be designed, sized and installed in <br />accordance with Sections 401 through 408. <br />409.5.3 Located at manifold. Where the appliance shut- <br />off valve is installed at a manifold, such shutoff valve shall <br />be located within 50 feet (15 240 mm) of the appliance <br />served and shall be readily accessible and permanently <br />identified. The piping from the manifold to within 6 feet <br />(1829 mm) of the appliance shall be designed, sized and <br />installed in accordance with Sections 401 through 408. <br />409.6 Shutoff valve for laboratories. Where provided with <br />two or more fuel gas outlets, including table-, bench- and <br />hood -mounted outlets, each laboratory space in educational, <br />research, commercial and industrial occupancies shall be pro- <br />vided with a single dedicated shutoff valve through which all <br />such gas outlets shall be supplied. The dedicated shutoff <br />valve shall be readily accessible, located within the labora- <br />tory space served, located adjacent to the egress door from <br />the space and shall be identified by approved signage stating <br />"Gas Shutoff" <br />SECTION 410 (IFGC) <br />FLOW CONTROLS <br />410.1 Pressure regulators. A line'pressure regulator shall be <br />installed where the appliance is designed to operate at a <br />lower pressure than the supply pressure. Line gas pressure <br />regulators shall be listed as complying with ANSI Z21.80. <br />Access shall be provided to pressure regulators. Pressure reg- <br />ulators shall be protected from physical damage. Regulators <br />installed on the exterior of the building shall be approved for <br />outdoor installation. <br />410.2 MP regulators. MP pressure regulators shall comply <br />with the following: <br />1. The MP regulator shall be approved and shall be suit- <br />able for the inlet and outlet gas pressures for the appli- <br />cation. <br />2. The MP regulator shall maintain a reduced outlet pres- <br />sure under lock -up (no -flow) conditions. <br />3. The capacity of the MP regulator, determined by pub- <br />lished ratings of its manufacturer, shall be adequate to <br />supply the appliances served. <br />4. The MP pressure regulator shall be provided with <br />access. Where located indoors, the regulator shall be <br />vented to the outdoors or shall be equipped with a leak - <br />limiting device, in either case complying with Section <br />410.3. <br />5. A tee fitting with one opening capped or plugged shall <br />be installed between the MP regulator and its upstream <br />shutoff valve. Such tee fitting shall be positioned to <br />allow connection of a pressure -measuring instrument <br />and to serve as.a sediment trap. <br />6. A tee fitting with one opening capped or plugged shall <br />be installed not less than 10 pipe diameters downstream <br />of the MP regulator outlet. Such tee fitting shall be <br />positioned to allow connection of a pressure -measuring <br />instrument. <br />7. Where connected to rigid piping, a union shall be <br />installed within 1 foot (304 mm) of either side of the <br />MP regulator. <br />2015 INTERNATIONAL FUEL GAS CODE" <br />
The URL can be used to link to this page
Your browser does not support the video tag.