j 1 I 2 I 3 I 4 I 5 <br /> STRUCTURAL & ELECTRICAL RENOVATION <br /> D 2222 BAKER AVE EVERETT WA 98201 D <br /> , <br /> GENERAL NOTES: ELECTRICAL SYMBOLS: ABBREVIATIONS: DRAWING SCHEDULE <br /> — 1. DEMOLISH ALL EXISTING ELECTRICAL MATERIALS, EQUIPMENT AND ITS RELATED NEW PANELBOARD AFCI ARC FAULT CIRCUIT INTERRUPTER NUMBER DESCRIPTION SHEET NO. — <br /> APPURTENANCES AND PROVIDE WITH NEW. <br /> AIC AMPERE INTERRUPTING CAPACITY GENERAL NOTES/SYMBOLS/ABBREVIATION/ <br /> 2. DRAWINGS SHOWN ARE DIAGRAMMATIC IN NATURE. VERIFY ACTUAL LOCATIONS AND LIGHTING FIXTURE, CEILING RECESSED A OR AMPS AMPERES E-001 SCHEDULE 17 of 21 <br /> DIMENSIONS OF ALL ELECTRICAL EQUIPMENT AND RELATED APPURTENANCES IN THE a MOUNTED DOWNLIGHT, LETTER INDICATES <br /> FIELD. SWITCHING DESIGNATION AWG AMERICAN WIRE GUAGE E-101 ELECTRICAL-LIGHTING PLANS 18 of 21 <br /> 3. ALL INSTALLATION SHALL BE IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF NFPA LIGHTING FIXTURE, WALL MOUNTED, CB CIRCUIT BREAKER <br /> a LETTER INDICATE SWITCHING DESIGNATION CKT CIRCUIT E-102 ELECTRICAL-POWER PLANS 19 of 21 <br /> 70, NEC (2020) AND RELATED LOCAL CITY AND STATE CODES. <br /> I I LIGHTING FIXTURES, 2-40W FLUORESCENT CO CARBON-MONOXIDE E-103 ELECTRICAL-SMOKE DETECTION PLANS 20 of 21 <br /> 4. ALL CONVENIENCE OUTLETS SHALL BE PROVIDED WITH AFCI PROTECTION UNLESS NOTED T-8 TYPE FOR BASEMENT, SUITABLE FOR <br /> OTHERWISE. MINIMUM RATING SHALL BE 15 AMPERES AND SHALL BE LISTED. DAMP LOCATION, SURFACED MOUNTED. ENCL ENCLOSURE E-201 ELECTRICAL-SECTIONS/LOAD SCHEDULE 21 of 20 <br /> C COORDINATE COLOR REQUIREMENT WITH THE BUILDING OWNER. (� LIGHTING FIXTURE, BATH ROOM VANITY GFCI GROUND FAULT CIRCUIT INTERRUPTER C <br /> 5. ALL STANDARD RECEPTACLES SHALL BE TAMPER RESISTANCE, GROUNDING-TYPE. THESE DUPLEX CONVENIENCE OUTLET KVA KILO-VOLT AMPERE <br /> INCLUDE A BUILT-IN SAFETY FEATURE THAT PREVENTS CHILDREN FROM STICKING ITEMS DUPLEX CONVENIENCE OUTLET, GROUNDING TYPE KWHR KILO-WATT HOUR <br /> INTO RECEPTACLE SLOTS. GgE M METER <br /> 6. PROVIDE WEATHERPROOF RECEPTACLES LOCATED WITHIN WET AND DAMP LOCATIONS. GAWP DUPLEX CONVENIENCE OUTLET, GFCI TYPE MCB MAIN CIRCUIT BREAKER <br /> WEATHERPROOF, OTHER DESIGNATION INCLUDES: <br /> 7. PROVIDE CONDUITS ON EXPOSED WIRING INSTALLATION IN BASEMENT AREA. NEC NATIONAL ELECTRICAL CODE <br /> DW - DISH WASHER NEMA NATIONAL ELECTRICAL MANUFACTURERS <br /> 8. PROVIDE UL LISTED LIGHTING FIXTURES. PROVIDE LIGHTING FIXTURE ABOVE SHOWER REF - REFRIGERATOR ASSOCIATION <br /> AREA AND WHIRPOOL SUITED FOR WET AND DAMP APPLICATION. RH - RANGE HOOD <br /> — WD - WASTE DISPOSER NFPA NATIONAL FIRE PROTECTION ASSOCIATION — <br /> 9. PROVIDE LIGHTING FIXTURES IN BASEMENT AREA SUITED FOR DAMP APPLICATION. RI - RANGE IGNITER PH PHASE <br /> WM - WASHING MACHINE <br /> 10. COORDINATE WITH THE BUILDING OWNER OR ITS DESIGNATED ARCHITECT PRIOR TO RECEPTACLE, CLOTHES DRYER. SE SERVICE ENTRANCE <br /> PROCUREMENT OF ALL LIGHTING FIXTURES. ®D SQ.FT. SQUARE FEET <br /> ®R <br /> RECEPTACLE, RANGE OUTLET <br /> 11. PROVIDE PANELBOARD THAT CONFORMS TO UL 67 AND NEMA PB1. UL UNDERWRITER LABORATORIES <br /> LIGHT SWITCH, ONE-WAY, SINGLE POLE, <br /> 12. COORDINATE WITH THE LOCAL POWER PROVIDER ON THE REPLACEMENT WORK OF ° LETTER INDICATES DEDICATED FIXTURES V VOLTS <br /> SERVICE ENTRANCE CONDUIT AND WIRING AS REQUIRED INCLUDING METERING AND S LIGHT SWITCH, THREE-WAY, SINGLE POLE, VA VOLT-AMPERE <br /> METER BASE REQUIREMENT. 3a LETTER INDICATE DEDICATED FIXTURES <br /> B 13. ALL BRANCH CIRCUIT WIRES SHALL BE THHN/THWN, COPPER. MINIMUM SIZE IS #12AWG. CA1 CIRCUIT HOMERUN, <br /> ALL CIRCUITS SHALL HAVE ITS OWN DEDICATED NEUTRAL CONDUCTORS. LETTER & NUMBER INDICATE CIRCUIT B <br /> NUMBER <br /> 14. INSTALL RECEPTACLES AT 16"ABOVE FINISH FLOOR MEASURED ON TOP OF THE DEVICE <br /> BATHROOM EXHAUST FAN <br /> 15. INSTALL LIGHT SWITCHES AT 48"ABOVE FINISH FLOOR MEASURED ON TOP OF THE <br /> DEVICE. MINIMUM RATING SHALL BE 15 AMPERES AND SHALL BE LISTED. COORDINATE ❑M UTILITY KWHR METER <br /> COLOR REQUIREMENT WITH THE BUILDING OWNER. <br /> O PHOTO-ELECTRIC SMOKE DETECTORS <br /> 16. INSTALL THE NEW PANELBOARD SO THAT THE CENTER OF THE GRIP OF THE OPERATING <br /> HANDLE OF THE CIRCUIT BREAKER LOCATED IN THE HIGHEST POSITION, SHALL NOT SC COMBINATION SMOKE/CO DETECTORS <br /> MORE THAN 6 } FEET ABOVE FINISH FLOOR. <br /> 17. POWER SYSTEM CAPACITY SHALL BE VERIFIED BY A COMPETENT PERSON PRIOR TO <br /> ADDING NEW LOADS THAT ARE NOT LISTED IN THE LOAD SCHEDULE. <br /> A A <br /> PREPARED BY: `c,B.SEE0G <br /> (,/ ----5-/c°cr''' <br /> PROJECT TITLE : OWNER: REVISIONS DRAWING NO. <br /> • <br /> �Ov oq w.�gr`�q' STRUCTURAL&ELECTRICAL STM DESCRIPTION DATE APPROVED <br /> TRIPLE V CONSULTANTS /4 RENOVATION <br /> (Bremerton and Whidbey Island,WA) MR. SAI SHANKAR E-OO1 <br /> TriplevconsultantsOmsn.com '� SHEET TITLE : 2222 BAKER AVENUE <br /> • 444 s � ELECTRICAL-GENERAL NOTES EVERETT,WA 98201 <br /> 360 632 2913 6 SCALE: AS INDICATED <br /> S?oWAL /SYMBOLS/ABBREVIATIONS ,CH EFT 1�n_F_ <br /> I WIRES: I /DRAWING SCHEDULE <br /> 1 I 2 13 I 4 I 5 <br />