• <br /> BPT Architecture �C O n/�2 <br /> 919 25th Ave S �J(_C, <br /> Seattle, WA 98144 1UN 1 <br /> (206) 325-1234 — 2�J21 <br /> CITY OF EVERETT <br /> June 7, 2021 Permit Services <br /> CORRECTION RESPONSE for BW2011-005 for 3202 51st PL SW <br /> Dear Mr. Bronder, <br /> 1. The structural detail reference by the Structural Engineer in the <br /> calculations have been indicated on A3. Also, the existing framing <br /> has been called out on plan. There is very little framing changes as <br /> the only thing affected is enlarging openings in walls and verifying the <br /> capacity of beams, confirming or replacing. <br /> 2. The most significant structural change is the post between the recreation <br /> room and the area with the wet bar is removed. A new GLB to the <br /> specification of the structural engineer is being installed. This beam runs <br /> generally, from east to west, it is the longer beam. Perpendicular to that <br /> beam is a shorter beam, which runs north/south, specified by the engineer. The short <br /> beam supports the main floor joists above. The longer beam receives the short beam. <br /> Main floor framing to the north of the beam is <br /> parallel to this beam. The floor framing and beams have been clarified on <br /> the drawings. See A3. This coincides with the recommendation and <br /> calculations of the structural engineer. Other than that, one opening is being <br /> enlarged approximately 50% and the bathroom is being enlarged without <br /> affecting the floor framing. <br /> 3. The permit drawings I have seen indicate a finished basement with <br /> similar room designations. I have not read the inspection report. We <br /> had thought the basement was existing habitable space. Egress is addressed on A3 as <br /> well as fire detection/Co2, and fan. <br /> 4. See reference above. Energy Credits of 1.5 are indicated, if required,are shown on A3. <br /> 5. Insulation R-values and glazing U-values call out is indicated on A3. <br /> Please let me know if you need further clarification. Perhaps it may be <br /> something we can cover over the phone. The client and contractor anticipate <br /> starting construction as soon as possible. My phone number is (206) 325-1234. <br /> Best regards, <br /> Bryce Thomas, Architect <br />
The URL can be used to link to this page
Your browser does not support the video tag.