My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 DORN AVE AB 2022-01-24
>
Address Records
>
DORN AVE
>
215
>
215 DORN AVE AB 2022-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 11:34:07 AM
Creation date
1/24/2022 11:33:38 AM
Metadata
Fields
Template:
Address Document
Street Name
DORN AVE
Street Number
215
Unit
AB
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> •• <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> _ loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> - Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> ' - some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> EFI PROPERTIES LLC American Home Planners <br /> (425)258-6400 <br /> Heating System Type: 0 All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Design Temperature Difference(AT) 49 <br /> Everett Paine AFB <br /> aT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> nsiruct1brs Conditioned Floor Area(sq ft) 1,420 <br /> Average Ceiling Height Conditioned Volume <br /> °cstrcciions Average Ceiling Height(ft) 8.0 11,360 <br /> Glazing and Doors U-Factor X Area = UA <br /> I Octruc ti0ns <br /> 0.30 208 62.40 <br /> Skylights U-Factor X Area = UA <br /> Instructic;cs 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> !utivctio,�s r— <br /> R-49-- --------------------- — =1 0.026 950 24.70 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> [No Vaulted Ceilings in this project -- <br /> - <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> nstrucrion. <br /> R-21 Intermediate 0.056 1,824 102.14 <br /> Floors U-Factor X Area UA <br /> instructions 0.029 503 14.59 <br /> L30 — V <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> tnstrt<cfic;a I No Below Grade Walls in this project. --- --- <br /> Slab Below Grade(see Figure 1) F-Factor X Len th UA <br /> Instructions No Slab Below Grade In this project_ <br /> Slab on Grade(see Figure 1) F-Factor X Len UA <br /> !nstriicEions — --- --_.---- <br /> Lo Slab on Grade In this project_ V J <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space <br /> ----— l.: 1.10 <br /> Sum of UA 203.83 <br /> Envelope Heat Load 9,988 Btu/Hour <br /> Figure 1. Sum OfUAXAT <br /> Air Leakage Heat Load 6,012 Btu/Hour <br /> VolumeX 0.6X AT .018 <br /> Above Grade Building Design Heat Load 15,999 Btu/Hour <br /> h. .�. <br /> Air Leakage+Envelope Heat loss <br /> Building and Duct Heat Load 17,599 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 24,639 Btu I Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Fumace <br /> Building and Dud Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.