My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6406 HIGHLAND DR 2022-01-24
>
Address Records
>
HIGHLAND DR
>
6406
>
6406 HIGHLAND DR 2022-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 2:33:47 PM
Creation date
1/24/2022 2:33:17 PM
Metadata
Fields
Template:
Address Document
Street Name
HIGHLAND DR
Street Number
6406
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Structural <br /> ZVELT ENGINEERING DESIGN, PLLC (ZED) Review <br /> Structural Engineering Services <br /> Letter <br /> Ms.Tatyana Shadyrya <br /> ArchStudio"Y.SHADYRYA" <br /> 22420 6th PL W <br /> Bothell, WA 98021 <br /> February 11, 2020 <br /> ZED Project: 19-148 <br /> Tsymbalyuk-Accessory Dwelling Unit(ADU) <br /> Re: Review Comments from City of Everett, BW1910-004 <br /> Dear Tatyana: <br /> The purpose of this letter is to respond to the City of Everett comments of November 20, 2019. <br /> Item numbers below correspond to the items listed in the comment letter. <br /> Item#4. <br /> Lateral analysis was not included with the engineering that was submitted. Pleases provide lateral <br /> analysis. <br /> ZED Answer: Lateral analysis was provided and included at Section 3, page 50 of the calculation package. <br /> Item#8. <br /> Please clarify the intent of"FOUNDATION NOTE#4"on sheet A03. <br /> ZED Answer: Note#4 on the"Foundation Notes", sheet A03 was inadvertently placed on the plan and eliminated. <br /> Item#11. <br /> Provide gravity calculations for the ledger attachment at the proposed deck. <br /> ZED Answer: Gravity calculations for the ledger attachment at the proposed deck is provided and attached to this <br /> letter. Ledger attachment noted on sheet A05 and detail 4/S3. <br /> Item#12. <br /> Show bolt edge distances on drawings at the proposed ledger as specified in Figure R507.2.2(1). <br /> ZED Answer: Bolt edge distances shown on sheet S2. <br /> Zvelt Engineering Design, PLLC reviewed the comments on the set of plans. <br /> Thank you for this review and comments. <br /> T <br /> Sincerely, c� J2c,K� <br /> Zvelt Engineering Design, PLLC I i <br /> Gabriela Siia, P.E. rat r :'� ,� <br /> rry' <br /> Attachments: Structural Calculations <br /> [EXPIRES 0;-C7-20 <br /> 6619132"d Ave NE, #126 Page 1,61 1 zvelt.eng@outlook.com <br /> Kirkland, WA 98033 425-242-8042 <br /> &-.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.