My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1327 112TH ST SE T MOBILE ANTENNA 2022-01-24
>
Address Records
>
112TH ST SE
>
1327
>
T MOBILE ANTENNA
>
1327 112TH ST SE T MOBILE ANTENNA 2022-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 3:45:16 PM
Creation date
1/24/2022 3:43:44 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
1327
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r 'N <br /> SHIPPING HOOKS TO <br /> MANUFACTURER: PURCELL SYSTEMS INC BE REMOVED AFTER -T� <br /> CABINET INSTALL ,y r, <br /> MODEL: HPL3 600A DC CABINET \�� ° <br /> ®i'I`r /,) A/� ®® <br /> WEIGHT: 430 LBS (WITHOUT EQUIPMENT) `'� I • fA.p <br /> 30" <br /> DIMENSIONS: 30"X32"X72" tr .00O HPL3/AN"D EXPANSION <br /> O'Q OOO CABINET CORNER <br /> NOTE: _ -- O VV MOUNTING POINTS 2" <br /> 0 (4) 7/8"0 HOLES FOR <br /> • ADDITIONAL KNOCKOUTS MAY BE REQUIRED ° HPL3 AND EXPANSION — <br /> AND CAN BE DRILLED ON SITE AS NECESSARY. CABINET 2-STRING • S I <br /> FOR CABINETS STARTING AT 501 THERE WILL 0 BATTERY RACK • <br /> BE A TOTAL OF (8) KNOCKOUTS(2) 0 MOUNTING POINTS <br /> HORIZONTAL ROWS OF(4) _ .. Glotel.. _ <br /> RACK ASSIGNMENT O I I rpi <br /> RACK RU SLOT DESCRIPTION (4) 7/8"0 HOLES FOR >Integrity DeliveredTM <br /> HPL3 4-STRING <br /> 15 BATTERY RACK ALL DC POWER <br /> 14 3RD AIRSCALE BATTERY <br /> MOUNTING POINT CABLES (BLUE)TO <br /> 13 IJ <br /> ® BE ROUTED AT THE12 ! 0 CORRECT KNOCKOUT I• $1CCAA6NET FIBER11 FlBER MUX - .0 TOOL REQUIRED FOR - ••° \ — <br /> •• I�KNOCKOUT RFDSVERSION4 <br /> 10 PUNCHING KNOCKOUTS.2ND AIRSCALE KNOCKOUTS THROUGH34038 34038/ PURCELL 2" PLINTH PURCELL 2" PLINTH <br /> F 7 FIBER MUX 2" PLINTH (OPTIONAL) PLAN VIEW 1 <br /> SIDE VIEW /// FIBER CABLES <br /> N 6 '1 f(YELLOW) O NEIL/ <br /> to 5 ISOMETRIC VIEW SILVERLAKE N/ <br /> DOOR CLOSED 30,000 WATT DC <br /> 1 <br /> rn 4 1ST AIRSCALE DOOR PLANT //////////,,,,-uL�.ro 19" RACK <br /> 3 --.• <br /> �� �I �I ADAPTERre <br /> PUD <br /> 48 POSITION DC ��-=- r _ -- ✓✓✓ <br /> N 2 FIBER MUX _` <br /> 1 DISTRIBUTION - --_ I0 <br /> ` == SE01608E <br /> m —.I -__ <br /> F 27 13/16" Y Y <br /> RECTIFIER SHELF /� VJ,) 69 1 16" - / E--�4= =. <br /> w DUAL FAN 'A \ °• 'OOO 8" 32" vi // %/////////////////////////3/ ALL FIBER <br /> w DIRECT AIR ' - 0.O OOO � _, f CABLES (YELLOW) <br /> 16 MV COOING <br /> SYSTEM j ,. 0 O 0 \ \ \N\ - _ 1331 112TH ST SE <br /> 1r' J•� TO BE ROUTED <br /> ce <br /> ttty AT THE RIGHT <br /> ('-. 30,000 WATT DC / y i � I \ _ CABINET <br /> OF THE EVERETT,WA 98208 <br /> x 14 CSR ` POWER PLANT L., SNOHOMISH COUNTY <br /> s. <br /> _ •y�� 0 I I I / / .�,.,r J <br /> F 13 THERMAL ��` \ \ )I <br /> a 12 4TH AIRSCALE SYSTEM // '' o N Taw 1 1 • 2 <br /> z 17 CONTROL I �� C:©. • <br /> .0 n n •\, `" I I I - 03-30-2021 <br /> E 10 FIBER MUX II 0 1 \ �)'1 1 ) ? <br /> o 9 • <br /> 'I.1• t�= NHL &R N .� M q <br /> w p 8 3RD LEGACY �� a -•"� - \ I �N��"+��" 1 �� <br /> m BBU ( M�� DI POSITION DC '.}A 1 \ <br /> p 7 �"�\, DISTRIBUTION \ _ <br /> rc 6 C4ABINETB ANCHORAGE R Iti ��\ OF WAS <br /> N 5 2ND LEGACY li O ��' - •? �C� <br /> o NU <br /> j `� (4) 5/8"0 HOLES FOR Q- _ _ <br /> l� '. A� " O BATTERY MOUNTING , :� .'+ Z <br /> U 4 <br /> ° 3 1ST LEGACY HEATER �' 1/� O t %• �/ <br /> 2 j� �� MOUNTING FOOTPRINT ;;�,3k: 1La� <br /> p eau PLAN VIEW INTERNAL ROUTING <br /> w 1 <br /> '►, 0.3; <br /> �0 ,•FC/STE• \-\ <br /> ISOMETRIC VIEW �S�ONAL ENG\ <br /> F DOOR OPEN 46„ <br /> m / 48" / 8" 30" 8" <br /> EXPIRES 01-09-2022 <br /> r <br /> / / <br /> 0 \ . �� FIBER ROUTE r _ <br /> REVISIONS <br /> a - - OPTION 1: IT IS • _ <br /> - = STRONGLY fl <br /> � • IllAIRSCALE `REV. DATE DESCRIPTION 8Y <br /> cc a V 1 rOOO' QED I A oa/m/zt ISSIIm FOR 90i CD REVIEW/''�� D ae�J (✓O O O�INCONVENIENTLY FROM �,� MUX/ a m/aA/zt ISSUED FOR tools CONSTRUCTION AF <br /> F ., KNOCKOUTS TO & INTERNAL AIRSCALE <br /> z O FROM COW WITH - EQUIPMENT&ARE NOT {ary l DEMUX _ <br /> WATER-TIGHT LB • <br /> FEASIBLE.SEE FIBER - <br /> a •0 •- - OR GROMMET O ROUTE OPTION 1. ALPHA POWER RECTIFIERS <br /> 0 - 0 (48 BREAKER '� o' l-"" (10 POSRIONS) <br /> 0 - a - . KNOCKOUT FOR SLOTS) tlt:— <br /> Z - ETHERNET FOR ALARMS n <br /> uj <br /> 172 <br /> j �• •••. a �' KNOCKOUTS FOR FIBER ROUTE OPTION 2: ROUTER "_` 9 <br /> z _ BATTERY WIRES REAR KNOCKOUTS CAN BE .- <br /> 88 _ • - UTILIZED FOR BOTTOM ���"•�' ,AIRSCALE <br /> ` - •• FIBER ROUTING FROM BASEBAND <br /> p S COVP TO AIRSCALE IF I ,_ <br /> L - A OPTION 1 IS UNAVAILABLE. I <br /> N O • <br /> 1 li O TITLE <br /> _ • J rFOR POWER.TELCO,INTENDED �•.�.1',� ,' LEGACY CABINET DETAILS <br /> 1/ <br /> r O - • O • <br /> BOTTOM FIBERS TO COW. `- <br /> '-�i►' BASEBAND <br /> ALL INCOMING CABUNG TO i�-•-•+••i / SHEET <br /> 3 r j� i te / <br /> m ,- O L✓6� BE IN RIGID OR FLEXIBLE a t•i,iJ <br /> z - _ _ • •_ ®O O O 0.® CONDUIT WRH AN lB. "" <br /> z I I \ I, 11 E ANY OF THE BOTTOM <br /> 8 KNOCKOUTS CAN BE USED <br /> FOR THE AC POWER FEED A._5 <br /> LEFT VIEW � FRONT VIEW RIGHT VIEW BACK VIEW FRONT VIEW (OPEN) <br /> p <br /> L' PURCELL HPL3 POWER PLANT/SITE SUPPORT CABINET <br /> —NI <br /> SCALE: N.T.S. GLOTELPROJECT#: J6561 <br /> 1 1'•X 17"SCAI P N T S <br />
The URL can be used to link to this page
Your browser does not support the video tag.