• • <br /> Vertical Fenestration Target Area Adjustment Calculations <br /> Project Title: TSI Aviation Date 03/17/2020 <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade _ <br /> Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door <br /> Project Areas-> VF= 986.0 NW= 17810.0 DR= 411.0 <br /> Existing Non-project Areas-> VF= NW= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert. Fen.Area <br /> 19207.0 X 30.0% 100 = 5762.1 <br /> J - <br /> Total Vertical / Delta Vertical Excess Vertical <br /> Fenestration Maximum Target JG/ Fenestration 0 Fenestration <br /> 986.0 - 5762.1 = -4776.1 greater = <br /> -4776.1 / Multiplier applied to all <br /> Project Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration / Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> calculate Target Vertical <br /> 986.0 - = 986.0 - 986.0 = 1.00 Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 17810.0 ± = 17810.0 - 17810.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> te <br /> Target Areas - UA ca/G adeTarget Wall Area Above- <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame X = <br /> Metal frame,fixed 902.0 X 1.00 = 902.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door 84.0 X 1.00 = 84.0 Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame 450.0 X 1.00 = 450.0 target areas on ENV-UA <br /> Metal Building X = <br /> Wood/Other frame X = <br /> Mass 17360.0 X 1.00 = 17360.0 <br /> Mass Transfer Deck X = <br /> Group R Mass X = <br /> Sum of Proposed 18796.0 Sum of Target 18796.0 Sum waof ll get <br /> vaertical <br /> de <br /> P 9 wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 X = <br /> 0.2<_PF<0.5 X = <br /> PF>_0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration <br /> to target areas on ENV- <br /> PF<0.2 X = SHGC <br /> 0.2<_PF<0.5 X = <br /> PF>_0.5 X = <br />