10/25/2021 City of Everett Page 2 <br /> 7:15;49AM <br /> INSPECTION ACTIVITY REPORT .3 <br /> 7/15/2021 7/15/2021 ELEC 06-ROUGH TJJO CORRECTION eTRAKiT Inspection 7/14/2021 11:37 PM SHARP ELECTRIC <br /> IN Request LLC <br /> Correction on both units. <br /> I did not find in code book that no more <br /> then 3 current-carrying conductors are <br /> allowed in one race way please refer to code <br /> book.As far as I know in 310.15(3)is <br /> adjustment factor that tells me if more then <br /> 3 i need to refer to table 310.15(b)(3)a <br /> which would reduce ampacity of the wire I <br /> used and the wire I used is#6 thhn that is <br /> rated at 75 amps at 90 deg colm thats the <br /> colm it falls in to then i would de-rate it to <br /> 80%is it says in table 310.15(b)(3)a 4-6 <br /> conductors adjust it to 80%=to 60 amps so <br /> i should be good on having 4 conductors in <br /> one race way and meet the 60 amps over <br /> current protections <br /> Thanks <br /> Contact Name:SHARP ELECTRIC LLC <br /> Site Address: 10617 ROSEWOOD AVE <br /> Phone:4253304002 <br /> e-Mail:Sharpelectricllc@gmail.com <br /> (7/15/2021 11:25 AM TJJO) <br /> -Fire stopping and contractors response on <br /> conductors okay <br /> -Can light in front of house shown to owner <br /> with bare conductors still present <br /> -Fan boxes still needed in attic <br /> -according to prints,counter receptacles do <br /> not appear to be 3'away from shower <br /> 7/16/2021 7/16/2021 ELEC 06-ROUGH TJJO APPROVAL eTRAKiT Inspection 7/15/2021 10:35 PM SHARP ELECTRIC <br /> IN Request LLC <br /> swapped out all bedroom and dining <br /> lighting boxes to fan rated,moved outlets <br /> next shower to center of venity.(owner was <br /> telling me he would have fixed glass panel <br /> there to separate shower from venity)found <br /> wire exposed and fixed it. <br /> Thanks <br /> Contact Name:SHARP ELECTRIC LLC <br /> Site Address: 10617 ROSEWOOD AVE <br /> Phone:4253304002 <br /> e-Mail:sharpelectricllc@gmail.com <br /> 8/3/2021 8/3/2021 ELEC 05-SERVICE TJJO CORRECTION eTRAKiT Inspection 8/2/2021 10:48 PM SHARP ELECTRIC <br /> Request LLC <br /> Both garages are open no doors yet <br /> Contact Name:SHARP ELECTRIC LLC <br /> Site Address:10617 ROSEWOOD AVE <br /> Phone:4257891719 <br /> e-Mail:sharpelectricllc@gmail.com <br /> (8/3/2021 11:26 AM TJJO) <br /> -Grounding electrode conductor needs to be <br /> installed in accessible side of service <br /> -gfci protection will be required on dryer <br /> circuit can be checked on final <br /> 8/6/2021 8/6/2021 ELEC 05-SERVICE TJJO APPROVAL eTRAKiT Inspection 8/5/2021 9:49 PM SHARP ELECTRIC <br /> Request LLC <br /> Factory installed ground lug in the line side. <br /> I moved the lug to load side and the ground <br /> wire.For it to be accessible <br /> Contact Name:SHARP ELECTRIC LLC <br /> Site Address:10617 ROSEWOOD AVE <br /> Phone:4257891719 <br /> e-Mail:sharpelectricllc@gmail.com <br /> INSP 12 C <br />