Laserfiche WebLink
0 • <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Wednesday,July 21, 2021 4:05 PM <br /> To: kiprono.biwott@gmail.com <br /> Subject: City of Everett Permit Services: 2314 Larlin Drive (B2107-044) - First Building Intake <br /> Review <br /> Attachments: 2018 IRC_Typical Code References_04-12-2021.docx; City of Everett - Residential <br /> Drawing Preparation.pdf <br /> Hello, Mr. Biwott. <br /> Your application has been received and a permit set up. However,the submitted documents are not sufficient <br /> for us to perform a review at this time. The Planning Department has also determined that the project is not <br /> sufficient to perform a review;they will issue a comment letter separately. Construction-level documents <br /> need to be submitted for review. Information is attached to provide guidance. Preliminary comments are <br /> provided below to assist in preparing the drawings, but these are not intended to provide a comprehensive <br /> review. Depending on your experience with the model codes and preparing documents, we recommend <br /> consulting with a design professional to assist you. <br /> 1. The submitted drawings are concept-level sketches. Construction drawings for the proposed project <br /> should be submitted for review. <br /> 2. The proposed project involves converting a single-family residence into an adult family home. The first <br /> page containing Section 1-4 has been submitted. However, Section 5 and the 8.5x11 floor plan have <br /> not been included;the floor plan should not be a sketch. See the following link for the required forms <br /> and documents: <br /> https://everettwa.gov/DocumentCenter/View/108/Adult-family-home-checklist-PDF <br /> 3. Each sleeping room should be classified per IRC Section R330.3. <br /> 4. Emergency escape windows are required per IRC Section R330.6. The minimum dimensions and areas, <br /> and maximum sill height, requirements for the windows should be specified in the drawings. <br /> 5. Continuing with the previous comment, structural details should be provided if the building requires <br /> modifications to install compliant egress windows. <br /> 6. Smoke and CO alarms are required per IRC Section R330.5. <br /> 7. Grab bars are required in the bathrooms per IRC Section R330.8. Details for the grab bars should be <br /> included in the drawings. Blocking should be provided in the walls capable of resisting a 200-pound <br /> load per Table R301.5. <br /> Review of your project will be performed in the order received once the required documentation has been <br /> submitted. Please let me know if you have questions. <br /> Drew Martin,P.E.,S.E. <br /> ElAssociate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8813 13200 Cedar Street, 2"d Floor, Everett,WA 98201 <br /> EVERETT Hours: M/W/Th/F: 7:30am-12:OOpm & 1:OOpm-3:OOpm;Tu: 1:OOpm-3:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> 1 <br />