My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 W MARINE VIEW DR 2022-02-28
>
Address Records
>
W MARINE VIEW DR
>
1700
>
1700 W MARINE VIEW DR 2022-02-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2022 11:51:32 AM
Creation date
2/15/2022 9:15:02 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1700
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> PUBLIC WO/EKS <br /> B1803-009 <br /> Benny Kim <br /> 7415 Lake Ballinger Way <br /> Edmonds, WA 98206 <br /> bennykimdesign©outlook.com <br /> Owner: Grace K Corporation <br /> Job Address: 1700 W Marine View Drive <br /> Plan Check No: B1803-009 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Kim, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. The plans should show that the building is in compliance for the exiting number of Type <br /> A sleeping rooms. Section 1107.6 <br /> 2. Details should be provided for the fire-resistive assemblies. Section 107.2.1 <br /> 3. The IIC and STC for the existing floor/ceiling assembly above the new sleeping units <br /> should be noted on the plans. Section 1207 <br /> 4. Exhaust fans for the new sleeping units should be shown on the plans and provided with <br /> ceiling radiation dampers. Section 717.6.2.1 <br /> 5. Provisions for ventilation should be shown on the plans. IMC Section 403.8 <br /> 6. It is not clear if the new corridor has two means of egress (which would be required per <br /> Table 1006.2.1) as there appears to be a wall at the western end. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br /> Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br /> Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br /> of Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> ' I2. <br />
The URL can be used to link to this page
Your browser does not support the video tag.