<br /> WAC 296-46B-900 ELECTRICAL PLAN REVIEW
<br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to
<br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is
<br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided
<br /> with this permit application.
<br /> *If item(a)-(ii, iii,or v)is selected,the work must also comply with section(a)-(vii). See arrow flow chart below.
<br /> (3)Electrical plan review,
<br /> E✓ (a)Electrical plan review is not reoutred for:
<br /> (i)Low voltage systems;
<br /> - (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project;
<br /> (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder
<br /> involved in the project,provided there is not a corresponding increase in the available fault current in any feeder..
<br /> _ (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution syste,,
<br /> -- does not include:
<br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F);
<br /> (8)An essential electrical system defined in NEC 517.2;or
<br /> (C)A required fire pump system.
<br /> ✓) (v)Modifications to existing electrical installations where all of the following conditions are met:
<br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed
<br /> 250 volts or for lighting circuits not exceeding 277 volts to ground;
<br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700,12(F);
<br /> (C)Does riot involve branch circuits or feeders of an essential electrical system as defined in NEC 511,2,
<br /> and
<br /> (D)Service or feeder load calculations are increased by 5%or less,
<br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total
<br /> rating of 9600 watts or less,
<br /> (vii)For installations in(a)(ii),(iii),and (v)of this subsection to be considered,the following must be available
<br /> to the electrical inspector before the work is initiated:
<br /> (A)A clear and adequate description of the project's scope;
<br /> (B)A load calculation(s);
<br /> (C)What the load changes are, providing both before and after panel schedules as needed;and
<br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is
<br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection
<br /> for that supply,
<br /> NOTE:Electrical plan review is not required for"Medical,dental,and chiropractic clinic"of which is a clinic or
<br /> physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more,per section
<br /> (1)(c)(xii).
<br /> (b)Electrical plan review is required for all other new or altered electrical projects in educational,institutional,or health care
<br /> occupancies defined in this chapter.
<br /> 0 (c)If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun.
<br /> Table aoo.i Table 900-2
<br /> health or P?rsonal Care racdiUeS Educational and Institutional Facilities.Places of Assembly,or Other Facilities
<br /> i Health or Personal Care tactful, Plan ReV14.ve
<br /> ry v< ttaa}u�rar! Educational,Institutional.or `Plan Rev1ew
<br /> Other Facility Types .,..Retlirired
<br /> a -1_ vef
<br /> a :at tr'srtanr' ±: ni4o.1a eek Notes to Tables 900-1 and 900.2.