FIRE BLOCKING, DRAFTSTOPS & SHAFT ENCLOSURES <br />1, FIRE PARTITIONS, FIREBLOCKING AND DRAFTSTOPS SHALL BE PROVIDED AS REQUIRED BY 2015 <br />IBC SECTIONS 708 AND 718. <br />A. ATTIC SPACE SHALL BE SUBDIVIDED INTO AREAS NOT EXCEEDING 3000 SQ/FT OR TWO <br />DWELLING UNITS WHICHEVER IS SMALLER. <br />IBC SECTION 708.4 EXCEPTION 6. FIREBLOCKING OR DRAFTSTOPPING IS NOT REQUIRED AT THE <br />PARTITION LINE IN BUILDINGS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED <br />THROUGHOUT IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, PROVIDED THAT <br />AUTOMATIC SPRINKLERS ARE INSTALLED IN COMBUSTIBLE FLOOR/CEDING AND ROOF/CEILING SPACES, <br />IBC SECTION 718.4.2 GROUPS R-1 & R-2 EXCEPTION 2. DRAFTSTOPPING IS NOT REQUIRED IN <br />BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE <br />WITH SECTION 903.3.1.1 <br />FIREBLOCKS AND DRAFTSTOPS. 1. GENERAL. IN COMBUSTIBLE CONSTRUCTION, FIRE -BLOCKING AND <br />DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND <br />HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A <br />ROOF OR ATTIC SPACE; AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR -CEILING <br />ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED. <br />2. FIREBLOCKS, WHERE REQUIRED. FIRE BLOCKING SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: <br />A. IN CONCEALED SPACES OF STUD AND WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE <br />CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL. <br />B. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES <br />SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. <br />C. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP ARID BOTTOM OF THE <br />RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF STAIRS IF THE WALLS <br />UNDER THE STAIRS ARE UNFINISHED. <br />D. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR <br />OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH <br />NONCOMBUSTIBLE MATERIALS. <br />E. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY -BUILT <br />CHIMNEYS. <br />3. FIREBLOCK CONSTRUCTION. EXCEPT AS PROVIDED IN ITEM D ABOVE, FIREBLOCKING SHALL CONSIST OF <br />2 INCHES NOMINAL LUMBER OR TWO THICKNESS OF 1 INCH NOMINAL LUMBER WITH BROKEN LAP JOINTS <br />OR ONE THICKNESS OF 23/32 INCH PLYWOOD WITH JOINTS BACKED BY 23/32 INCH PLYWOOD OR ONE <br />THICKNESS OF 3/4 INCH TYPE 2-M PARTICLE BOARD WITH JOINTS BACKED BY 3/4 INCH TYPE 2-M <br />PARTICLE BOARD. IBC SECTION 718.2.1 <br />FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT ASBESTOS BOARD, MINERAL FIBER, GLASS FIBER <br />OR APPROVED MATERIALS SECURELY FASTENED IN PLACE. LOOSE -FILL INSULATION MATERIAL SHALL NOT <br />BE USED AS A FIRE BLOCK UNLESS SPECIFICALLY FIRE TESTED. <br />WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND -TRANSMISSION CONTROL SHALL HAVE FIRE <br />BLOCKS OF MINERAL FIBER OR GLASS FIBER OR OTHER APPROVED NONRIGID MATERIALS, <br />4. ALL SHAFT ENCLOSURES SHALL COMPLY W/ 2015 IBC SECTION 713.1, 713.4, 713,5 & 713.7 <br />a11111151 Ill 9 .. <br />MIA <br />iEll <br />SECTIONS <br />EARTH iii=Ti=Ti <br />CONCRETE ° o ° " u <br />WIN <br />PLYWOOD <br />FINISH WOOD <br />GRAVEL "W FRAMING <br />ASPHALT 1��\.41�11111� BLOCKING r77771 <br />MECHANICAL <br />1. WATER HEATERS WITH NON -RIGID WATER CONNECTION AND OVER 4 FEET HIGH SHALL BE ANCHORED <br />STRAPPED TO RESIST EARTHQUAKE MOTION PER 2015 UPC SEC. 507.2 <br />2. ALL CLOTHES DRYERS SHOULD BE EXHAUSTED TO THE OUTSIDE, IMC SECTION 504.6 <br />3. CLOTHES DRYER EXHAUST DUCTS SHALL NOT BE PUT TOGETHER WITH SHEET METAL SCREWS OR OTHER <br />FASTENING MEANS WHICH EXTEND INTO THE DUCT. <br />4. UNITS TO BE HEATED BY ELECTRIC HEAT. <br />5. ALL MECHANICAL VENTING POINTS OF DISCHARGE SHOULD BE AT LEAST 3 FEET FROM OPERABLE OPENINGS <br />INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES PER IMC SECTION 501.3,1 & 804.3 <br />6. SEE WASHINGTON ENERGY CODE REQUIREMENTS FOR ADDITIONAL INFORMATION <br />SOUND CONTROL <br />1. ALL FLOORS, CORRIDOR WALLS AND PARTY WALLS SHALL ATTAIN A STC RATING OF 50 MIN, PER 2015 IBC SECTION 1207 <br />EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH IBC SEC. 2702. SEE ELECTRICAL FOR LOCATIONS <br />1. EXIT SIGNS PER SEC. 27Q2.2.5 <br />2. MEANS OF EGRESS ILLUMINATION PER SEC. 2702.2.11 <br />HANDRAILS <br />ALL HANDRAILS MUST EXTEND AT THE SAME SLOPE FOR A DISTANCE OF ONE TREAD BEYOND THE BOTTOM <br />RISER AND 12" HORIZONTALLY AT THE TOP RISER. ALL EXTENSIONS SHALL RETURN TO THE WALL AT ENDS <br />2015 IBC SEC. 1014. <br />ALL HANDRAILS SHALL HAVE SPACE OF NOT LESS THAN 1-1/2" BETWEEN WALL AND THE HANDRAIL. <br />HANDRAILS MUST HAVE THEIR ENDS RETURNED OR TERMINATED IN NEWEL POST OR SAFETY TERMINALS. <br />GUARDRAILS FOR STAIRS, BALCONIES AND LANDINGS SHALL CONFORM TO 2015 IBC SEC. 1015 MAXIMUM <br />CLEARANCE BETWEEN INTERMEDIATE RAILS IS LESS THAN 4" AND GUARDRAIL SHALL BE 42". <br />RAILINGS: NOT LESS THAN 34" OR MORE THAN 38" ABOVE NOSING OF TREAD. <br />STAIR RISE AND RUN: NOT LESS THAN 4" NOR MORE THAN 7" - TREADS SHALL BE NOT LESS <br />THAN 11" <br />NOTE: STAIRWAYS SHALL BE MINIMUM 36". HANDRAILS MAY PROJECT NOT MORE THAN 3-1/2" <br />INTO EACH SIDE OF THE REQUIRED WITH PROJECTIONS SUCH AS TRIM ARE LIMITED TO 1-1/2" <br />EACH SIDE PER EGRESS WIDTH 2O15 IBC SECTION 1005. PROJECTIONS PER 2015 IBC SECTION 1014.8 <br />EXPOSED POSTS AND RAILS AT EXTERIOR BALCONIES SHALL BE PRESSURE TREATED WOOD PER <br />2015 IBCSEC. 2304.12.2.2 <br />THE HANDGRIP PORTION OR HANDRAILS SHALL BE NOT LESS THAN 1-1/2" NOR MORE THAN 2" <br />IN CROSS SECTIONAL DIMENSION OR THE SHAPE SHOULD PROVIDE AN EQUIVALENT GRIPPING <br />SURFACE. THE HANDGRIP PORTION SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. <br />GRASPABILITY PER 2015 IBC SEC. 1014.3 <br />RAILINGS AND PARTIAL HEIGHT WALLS SHALL WITHSTAND A 50 POUND PER FOOT HORIZONTAL <br />FORCE. IBC SECTION 1607.8 <br />MISCELLANEOUS REQUIREMENTS <br />1. WALLS SHALL BE 5/8" TYPE "X" GYPSUM BOARD (1 HOUR) THROUGHOUT. <br />2. BUILDING DEPARTMENT APPROVED PLANS SHALL BE ON JOB SITE AT ALL TIMES. <br />3. ALL DRYER VENTS, KITCHEN HOOD FANS AND BATH FANS SHALL BE VENTED TO EXTERIOR <br />WITH RIGID, SMOOTH WALL DUCTS. <br />4. ROOF DRAINS SHALL BE CONNECTED TO TIGHT LINES <br />5. A WEATHER -RESISTIVE BARRIER MUST APPLIED TO EXT. WALLS PER 2015 IBC SEC. 1403.2 <br />6, THE BUILDING SHALL HAVE A QUICK -RESPONSE SPRINKLER HEADS AS PER IBC SEC. 903.3.1.1 NFPA 13 <br />7. ALL EXITS SHALL BE ILLUMINATED IN CONFORMANCE WITH .2015 IBC SEC. 1008.1 <br />8. EXIT SIGNS SHALL MEET ALL THE REQUIREMENTS OF 2015 IBC SEC. 1008 & 1013, IN REGARD TO GRAPHICS, <br />ILLUMINATION, & POWER SUPPLY, <br />9. ALL DOORS, WINDOWS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES NEED TO <br />HAVE A LEVER HANDLE OR SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM <br />PRESSURE AS PER IC ANS1117.1-2009, SEC. 404.2.E <br />10. GLAZING IN ALL DOORS MUST BE SAFETY GLAZING PER IBC SEC. 2406.4 <br />11. DUCT PENETRATIONS OF SHAFT ENCLOSURES SHALL BE PROTECTED BY FIRE/SMOKE DAMPERS, SEE <br />IBC SEC. 717.5.3. SEE ALSO THE RELATED EXCEPTIONS. <br />12. WHERE WOOD STRUCTURAL PANELS ARE INSTALLED BETWEEN THE FIRE PROTECTION AND THE WOOD <br />STUDS IN A RATED ASSEMBLY, THE LENGTH OF THE FASTENERS USED TO ATTACH THE GWB NEEDS <br />TO BE INCREASED BY AN AMOUNT AT LEAST EQUAL TO THE THICKNESS OF THE WOOD STRUCTURAL <br />PANEL. <br />14, EMERGENCY LIGHTING <br />EMERGENCY LIGHTING FOR EGRESS AS SHOWN ON THE GENERAL FLOOR PLANS AND LIFE SAFETY PLANS SHALL <br />PROVIDE ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE. THE POWER SUPPLY <br />MEANS OF EGRESS SHALL BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. THE EMERGENCY POWER SYSTEM <br />OR GENERATOR. <br />SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, <br />15. LANDSCAPING <br />PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING LANDSCAPING WITHIN PUBLIC RIGHT-OF-WAY. <br />16, ROOF MOUNTED EQUIPMENT <br />THERE WILL BE NO EXTERIOR SITE OR ROOF MOUNTED EQUIPMENT THAT WILL REQUIRE SCREENING <br />17. PARKING LIGHTING FIXTURES <br />THE PARKING LOT LIGHTING SHALL HAVE FIXTURES THAT WILL BE FULL CUT-OFF (ZERO PERCENT CANDLEPOWER AT <br />NINETY DEGREES HORIZONTAL AND TEN PERCENT MAXIMUM CANDLEPOWER AT NINETY DEGREES FROM VERTICAL) AND <br />DARK SKY RATED. <br />18. SENSORY IMPAIRMENT REQUIREMENTS <br />ALL A TYPE UNITS SHALL HAVE AN ALARM SYSTEM THAT IS BOTH VISUAL AND AUDIBLE. <br />HEARING AND VISION IMPAIRED UNITS <br />1. AUDIBLE/VISUAL 24 CFR 8.22; ADAS 809.5, 702; ICC A117,1-2009 1006 EMERGENCY ALARMS IF <br />EMERGENCY WARNING SYSTEMS ARE CONNECTED THROUGH THE BUILDING, ENSURE THEY ARE BOTH <br />AUDIBLE & VISUAL. THE SOUND SHALL EXCEED THE PREVAILING EQUIVALENT SOUND LEVEL IN ROOM <br />li <br />OR SPACE BY AT LEAST 15 DECIBELS OR EXCEED ANY MAX. SOUND LEVEL WITH A DURATION 0�-r <br />30 <br />SECONDS BY 5 DECIBELS, WHICHEVER IS LOUDER. PER ADAS, SOUND LEVELS FOR ALARM SIGNALS <br />SHALL NOT EXCEED 110 DECIBELS. <br />2. AUXILIARY VISUAL EMERGENCY ALARMS AT BEDROOMS 24 CFR 8.22 <br />IF EMERGENCY WARNING SYSTEMS ARE CONNECTED THROUGH THE BUILDING, AT ALL ACCESSIBLE <br />BEDROOMS, ENSURE A VISUAL ALARM CONNECTED TO BUILDING EMERGENCY ALARM SYSTEM OR A <br />STANDARD 110-VOLT ELECTRICAL RECEPTACLE INTO WHICH SUCH AN ALARM COULD BE CONNECTED <br />(WITH INSTRUCTIONAL LITERATURE). <br />3. PRIMARY UNIT ENTRANCE <br />NOTIFICATION & IDENTIFICATION ADAS 809.5.5; ICC A117.1-2009 1006 <br />ENSURE HARD -WIRED ELECTRIC DOORBELL IS PROVIDED AT PRIMARY ENTRANCE, WHICH WHEN <br />ACTIVATED INITIATES AUDIBLE TONE 8c VISIBLE SIGNAL WITHIN UNIT. WHERE VISIBLE SIGNALS ARE <br />LOCATED IN SLEEPING AREAS, PROVIDE CONTROLS TO DEACTIVATE THE SIGNAL. ADDITIONALLY, A MEANS <br />OF VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE DOOR IS TO BE PROVIDED WHICH ALLOWS <br />FOR A MIN. 180 DEGREE RANGE OF VIEW. WE RECOMMEND PLACING AT 43" MAX. AFF PER ICC <br />A117.1-2009 404.2.10. <br />OCCUPANCY AND CONSTRUCTION <br />1. ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES PROVIDED ON <br />OR WITHIN THE WALLS SHALL BE INSTALLED AND SEALED TO PROTECT THE STRUCTURAL ELEMENTS FROM <br />MOISTURE. <br />2. ALL SHOWER SURROUNDS Si -TALL HAVE A HARD, SMOOTH AND NON -ABSORBENT WALL SURFACE TO A <br />MINIMUM OF 70" ABOVE THE DRAIN CUTLET. <br />3. ALL GYPSUM WALLBOARD USED AS A BASE FOR THE TILE OR WALL PANELS IN SHOWER ENCLOSURES <br />MUST BE WATER-RESISTANT GYPSUM BACKING BOARD AND NOT INSTALLED OVER A VAPOR BARRIER. <br />4. FLOORS AND WALLS TO A HEIGHT OF 4 FEET IN PUBLIC RESTROOMS SHALL HAVE A SMOOTH, HARD, <br />N� E,S A�E PEA tBG SECTION 121-,, <br />5, THE REQUIRED SMOKE DETECTORS 8c CARBON MONOXIDE DETECTORS SHALL RECEIVE THEIR PRIMARY <br />POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE z <br />AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. <br />�6 �Etf°IPJ�EI�Tf DOERS SFALt IXGEED Dt�NIEf51 LCiOF CE 1� C <br />GLASS DISC WITH METAL HOLDER THAT CAN SUSTAIN A TEMPERATURE OF 1700 DEGREES PER <br />IBC SEC, 716.5.3 EXCEPTION #1 <br />7. EXPOSED POSTS AND RAILS AT EXTERIOR BALCONIES SHALL BE PRESSURE TREATED WOOD PER <br />2015 IBC SEC. 2304.12.2.2 <br />8. ATTACHMENTS FOR ASPHALT SHINGLES SHALL BE AS FOLLOWS: INSTALLED OVER A VAPOR BARRIER. <br />FASTENER NAILS: USE HOT GALVANIZED STEEL OR ALUMINUM SHARP POINTED CONVENTIONAL BARBED <br />SHANK ROOFING NAILS 11 OR 12 GAUGE) WITH AT LEAST 3/8" DIAMETER HEADS. NAILS ARE TO BE <br />OF SUFFICIENT LENGTH TO PENETRATE 3/4" INTO SOLID DECKING OR THROUGH PLYWOOD SHEATHING. <br />9. RIGID INSULATION SHALL HAVE A FLAME -SPREAD RATING OF NOT MORE THAN 75 AND A SMOKE -DEVELOPED <br />RATING OF NOT MORE THAN 450 WHEN TESTED FOR STANDARD 42-1 IBC SEC. 2603. <br />10. BUILDINGS SHALL BE PROVIDED WITH A MANUAL FIRE ALARM SYSTEM AND PLANS SUBMITTED <br />TO THE FIRE DEPARTMENT FOR APPROVAL, PER IBC SEC, 907.2,9 <br />11. WHERE THRESHOLDS ARE PROVIDED FOR DOORWAYS OTHER THAN ACCESS TO STORAGE ROOMS AND KITCHENS, <br />THE THRESHOLDS SHALL NOT BE MORE THAN 1/2" HIGHER THAN FLOOR LEVEL. <br />WHEN HANDICAPPED ACCESS IS NOT REQUIRED, THIS DIMENSION SHOULD NOT EXCEED 3/4". <br />12, ALL ROOFS SHALL HAVE A MINIMUM SLOPE FOR DRAINAGE PER 2015 IBC SEC. 1503.4 <br />13. FLOOR TEXTILES IN PUBLIC AREAS, COURTYARDS, ACCESSIBLE AND TYPE A DWELLING UNITS MUST BE FIRM, STABLE <br />AND SLIP -RESISTANT PER ANSI A117.1-2009 SECTION 302. <br />FIRE DEPARTMENT REQUIREMENTS <br />1. PORTABLE FIRE EXTINGUISHERS ARE TO BE PROVIDED THROUGHOUT THE PROJECT PRIOR TO OCCUPANCY. <br />EXTINGUISHERS SHALL MEET REQUIREMENTS OF LOCAL FIRE DEPARTMENT, <br />2. EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED WHERE THEY WILL BE READILY ACCESSIBLE AND <br />IMMEDIATELY AVAILABLE IN THE EVENT OF FIRE. PREFERABLY THEY SHALL BE LOCATED ALONG NORMAL <br />PATHS OF TRAVEL, INCLUDING EXITS FROM AN AREA. MOUNT EXTINGUISHERS WITH THEIR TOPS OF <br />THE HANDLE NO HIGHER THAN 48" ABOVE FINISHED FLOOR. ENSURE THAT FIRE EXTINGUISHERS PROTRUDE <br />NO MORE THAN 4" INTO THE ACCESSIBLE ROUTE, AND THE BOTTOM EDGE MUST BE NO HIGHER THAN 27", <br />3. APPROVED ADDRESS NUMBERS SHALL BE PROVIDED FOR EACH BUILDING IN A HIGHLY VISIBLE LOCATION <br />FACING THE STREET FROM WHICH THE BUILDING IS ADDRESSED. SAID BUILDING ADDRESS NUMBERS SHALL <br />BE NOT LESS THAN 4-INCHES IN HEIGHT AND CONTRAST WITH THEIR BACKGROUND. IF A BUILDING IS <br />ACCESSED FROM A DRIVEWAY WHERE IT IS NOT VISIBLE FROM THE FIRE ACCESS ROAD, AN APPROVED <br />MONUMENT -TYPE ADDRESS SIGNS SHALL BE PROVIDED AT THE ENTRANCE TO THE DRIVEWAY. APARTMENT <br />LIVING UNITS SHALL BE PROVIDED WITH ADDRESS DESIGNATIONS NOT LESS THAN 4-INCHES IN HEIGHT. <br />2015 IFC SEC. 505 <br />4. A FIRE ALARM SYSTEM CONFORMING TO REQUIREMENTS OF 2015 IFC, SECTION 907 AND INSTALLED IN <br />ACCORDANCE WITH NFPA 72 IS REQUIRED AND SHALL BE PROVIDED. <br />a. FIRE ALARM PLANS SHALL BE SUBMITTED AS A DEFERRED SUBMITTAL. PLANS SHALL BE <br />DESIGNED BY A QUALIFIED PERSON, AND REVIEWED BY A REGISTERED FIRE PROTECTION <br />ENGINEER AND/ OR ELECTRICAL ENGINEER WITH REVIEW COMMENTS SUBMITTED. PROVIDE <br />TWO COMPLETE SETS OF DRAWINGS, SPECIFICATIONS AND REVIEW COMMENTS. PLANS IN <br />ELECTRONIC FORM ACCEPTED AND PREFERRED. <br />5. POWER SOURCE FOR SMOKE DETECTORS WITHIN TENANTED SPACES SHALL CONFORM TO IBC/IFC 907.2.9, <br />6. FIRE ALARM CONTROL PANEL AND ANY OTHER FIRE PROTECTION/ DETECTION EQUIPMENT REQUIRING <br />120 VAC, SHALL BE SUPPLIED BY DEDICATED CIRCUIT BREAKER(S). OTHER (NON -FIRE PROTECTION/ DETECTION) <br />EQUIPMENT SHALL NOT SHARE THE FIRE ALARM CIRCUIT(S). CIRCUIT BREAKERS(S) FOR FIRE ALARM CIRCUITS(S) <br />SHALL BE RED, "LOCKED" .AND CLEARLY MARKED "FIRE ALARM CIRCUIT CONTROL". <br />a. AT LEAST TWO INDEPENDENT AND RELIABLE POWER SUPPLIES SHALL BE PROVIDED FOR FIRE <br />ALARM SYSTEMS, ONE PRIMARY AND ONE SECONDARY, EACH OF WHICH SHALL BE OF ADEQUATE <br />CAPACITY FOR APPLICATION. (NFPA 72. 4,4.1.3.1) <br />b. A DEDICATED BRANCH CIRCUIT SHALL SUPPLY PRIMARY POWER. (NFPA 72, 4.4,1.4.1) <br />1. THE DEDICATED BRANCH CIRCUITS) AND CONNECTIONS SHALL BE MECHANICALLY <br />PROTECTED. (NFPA 72,4.4.1.4.2.1) <br />2. CIRCUIT DISCONNECTING MEANS (CIRCUIT BREAKER) SHALL HAVE RED MARKING, SHALL <br />BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, AND SHALL BE IDENTIFIED AS "FIRE <br />ALARM CIRCUIT." (NFPA 72, 4.4.1.4.2.2) <br />3. THE LOCATION OF THE CIRCUIT DISCONNECTING MEANS SHALL BE PERMANENTLY <br />IDENTIFIED AT THE ALARM CONTROL UNIT. ihIFPA 72, 4.4.1.4.2,3.) <br />c. THE SECONDARY POWER SUPPLY SHALL CONSIST OF ONE OF THE FOLLOWING, <br />1. A STORAGE BATTERY DEDICATED TO THE ALARM SYSTEM ARRANGED IN ACCORDANCE <br />WITH NFPA 72 4,4,1.8. <br />2. A DEDICATED BRANCH CIRCUIT OF AN AUTOMATIC -STARTING, ENGINE -DRIVEN GENERATOR <br />ARRANGED IN ACCORDANCE WITH NFPA 4.4.1.9.3.1 AND STORAGE BATTERIES DEDICATED TO <br />THE FIRE ALARM SYSTEM WITH 4 HOURS OF CAPACITY ARRANGED IN ACCORDANCE <br />WITH NFPA 72, 4,4.1.8. <br />3. THE SECONDARY POWER SUPPLY SHALL HAVE SUFFICIENT CAPACITY TO OPERATE THE <br />FIRE ALARM SYSTEM UNDER QUIESCENT LOAD (SYSTEM OPERATING IN A NONALARM <br />CONDITION) FOR A MINIMUM OF 60 HOURS AND, AT THE END OF THAT PERIOD, SHALL BE <br />CAPABLE OF OPERATING ALL ALARM NOTIFICATION APPLIANCES USED FOR EVACUATION OR TO <br />DIRECT AID TO THE LOCATION OF AN EMERGENCY FOR 5 MINUTES. <br />4. AN NFPA 13 AUTOMATIC FIRE EXTINGUISHING SPRINKLER SYSTEM DESIGNED AND <br />INSTALLED IN ACCORDANCE WITH 2O15 IFC, SEC. 903 AND NFPA 13 IS REQUIRED <br />AND SHALL BE PROVIDED. <br />a. AUTOMATIC FIRE SPRINKLER AND UNDERGROUND FIRE MAIN PLANS SHALL BE SUBK41TTED AS <br />A DEFERRED SUBMITTAL. PLANS SHALL BE DESIGNED BY A STATE CERTIFIED DESIGNER AND <br />BEAR THE STAMP OF THE DESIGNER. PROVIDE AT LEAST TWO COMPLETE SETS OF <br />DRAWINGS, SPECIFICATIONS AND CALCULATIONS. PLANS IN ELECTRONIC FORM ARE <br />ACCEPTED AND PREFERRED. ALL WORK AND MATERIALS SHALL BE IN COMPLIANCE WITH THE <br />APPROPRIATE NFPA SPRINKLER SYSTEM DESIGN AND INSTALLATION STANDARD (NFPA 13 & 13R) <br />AND OTHER RELATED PROTECTION SYSTEM DESIGN STANDARDS. <br />NOTE: NOT A CODE REQUIREMENT, HOWEVER, IF SPRINKLERED, USE OF CONCEALED <br />SPRINKLER HEADS IN CLOSETS, ETC, IS ADVISED TO MINIMIZE POTENTIALS FOR SPRINKLER <br />HEAD DAMAGE. <br />7. EMERGENCY VEHICLE ACCESS <br />UNOBSTRUCTED FIRE LANES SHALL BE MAINTAINED THROUGHOUT THE PROJECT, "NO PARKING FIRE LANE" MARKINGS <br />SHALL BE INSTALLED. <br />8. EMERGENCY RADIO COVERAGE. <br />THERE SHALL BE EMERGENCY RADIO COVERAGE AS REQUIRED BY CITY OF ARLINGTON EMERGENCY COVERAGE ORDINANCE <br />THIRD PARTY TESTING IS REQUIRED PRIOR TO OCCUPANCY TO SHOW COMPLIANCE, <br />TEST RIGHT AFTER SHEETROCK. <br />9. CARBON MONOXIDE DETECTORS <br />DEFERRED WITH FIRE ALARM <br />10. FIRE DOOR ASSEMBLIES WITH SIDE HINGED OR PIVOTED SWINGING DOORS SHALL BE TESTED IN ACCORDANCE WITH NFPA252 OR <br />UL 10C DOORS #31 & #33. <br />11. SPRINKLER SYSTEM REQUIREMENTS <br />1. SPRINKLERS FOR CONCEALED SPACES. <br />ALL CONCEALED SPACES BETWEEN FLOORS, ROOFS AND PORTE COCHERE SHALL HAVE SOLID INSULATION, <br />..LI,:EED�FP;A,SEC-TiQN- <br />2. SPRINKLER SYSTEM TO EXTEND TO EXTERIOR BALCONY AREAS PER IBC SECTION 1406,3 EXCEPTION 3. <br />12. EMERGENCY RESPONDER SAFETY FEATURES <br />a. SHAFTWAY MARKINGS. VERTICAL SHAFTS SHALL BE IDENTIFIED AS REQUIRED BY IBC SEC 914.1.1 AND 914,1.2. <br />1. EXTERIOR ACCESS TO SHAFTWAYS PER IBC SEC. 914.1.1 <br />2. INTERIOR ACCESS TO SHAFTWAYS PER IBC SEC. 914,1.2 <br />b. EQUIPMENT ROOM IDENTIFICATION PER IBC SEC. 914.2 <br />13. ACCEPTANCE TESTING PER IBC SECTION 909.18 <br />DEVICES, EQUIPMENT, COMPONENTS AND SEQUENCES SHALL BE INDIVIDUALLY TESTED, THESE TEST, IN ADDITION <br />TO THOSE REQUIRED BY OTHER PROVISIONS OF THIS CODE, SHALL CONSIST OF DETERMINATION OF FUNCTION, <br />SEQUENCE AND, WHERE APPLICABLE, CAPACITY OF THEIR INSTALLED CONDITION. <br />BUILDING QLAIF�C�TIQN� <br />1, (4 _ STORIES - TYPE V-A 1 <br />2. Oc�tlP A1YL AS I€� <br />APARTMENTS - R-2 <br />3. ALARMS & SMOKE DETECTORS SHALL BE PER 2015 IBC SECTION 907.2,9 <br />4. ALL PARTY WALLS AND FLOORS BETWEEN UNITS SHALL BE 1 HOUR & HAVE AN STC (50). <br />PER 2015 IBC SECTION 1207 <br />PER TABLE 601 INTERIOR. NONSEARING WALLS AND PARTITIONS DO NOT REQUIRE A RATING <br />CONSTRUCTION <br />ALL CONSTRUCTION TO BE IN ACCORDANCE WITH 2O15 IBC. UPC, IMC AND 2014 NEC <br />& CITY OF EVERETT ZONING CODE. <br />DESIGN LOADS - SEE SHEET S-1 <br />HEAT SOURCE - ELECTRIC HEAT <br />2015 WASHINGTON STATE ENERGY CODE: COMPONENT PERFORMANCE, ZONE 1, ELECTRIC RESISTANCE HEAT. <br />WORKSHEET AVAILABLE. <br />2015 WASHINGTON STATE VENTILATION & INDOOR AIR QUALITY CODE <br />FOR VENTILATION USE 2015 IMC, CHAPTER 4. 1 <br />BATH FANS SHALL SERVE AS WHOLE HOUSE VENTILATION- 44�­CFM'MIN LOW SETTING PER IMC TABLE 403.8.1. CONTINUOUS <br />kTE" I CWWUOUS-Q�-���,-Q F <br />LAUNDRY ROOM FANS REQUIRE 20 CFM CONTINUOUS OR 50 CFM INTERMITTENT. <br />INSULAT(OT -- - _ - - - - - j l� - - - - <br />EXTERIOR WALLS - R-21 <br />TOP FLOOR CEILING - R-49 <br />PARTY WALLS - R-1 1 <br />SLAB ON GRADE - R--10 RIGID INSULATION <br />WASHINGTON STATE ENERGY REQUIREMENTS <br />THE BUILDING SHALL COMPLY WITH THE FOLLOWING TO MEET THE WASHINGTON STATE ENERGY CODE <br />1. ALL EXTERIOR WALLS SHALL BE 2 X 6 STUDS WITH R-21 INSULATION. <br />2. ALL ATTIC CEILING SHALL HAVE R-49 INSULATION (UNLESS NOTED OTHERWISE) <br />3. EXTERIOR WALLS TO HAVE A VAPOR. BARRIER, (FACED BATT INSULATION WITH TABS STAPLED TO THE <br />FACE EDGE OF STUDS AND/OR JOISTS SHALL BE CONSIDERED A VAPOR BARRIER. <br />4, SHOWERS MUST HAVE A CONTROL. DEVICE THAT LIMITS FLOW TO 2.50 G,P.M. <br />5. WATER HEATERS MUST COMPLY WITH NAECA, AND BE SO LABELED. <br />6, CAULKING, SEALING AND WEATHERSTRIPPING ARE REQUIRED AROUND DOORS AND WINDOWS, BETWEEN <br />FRAMING INTERSECTIONS SUCH AS WALLS AND FOUNDATIONS, PENETRATIONS FOR PLUMBING, <br />WIRING AND DUCTING MUST ALSO BE SEALED. <br />7. A MINIMUM OF 1" OF AIR SPACE MUST BE PROVIDED BETWEEN THE INSULATION AND THE SHEATHING <br />AND ATTIC VENTILATION PROVIDED ACCORDING TO THE IBC SECTION 1203 <br />B. INSULATE HOT AND COLD WATER PIPES PER WSEC SECTION C403,2.9- TABLE C403.2.9 <br />9. ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR WALLS MUST BE SEALED AT BACK OF <br />RECEPTACLE OR SEALED WITH FACE PLATE GASKETS. <br />10. SEAL RIM JOIST BETWEEN HEATED FLOOR OR USE A PRODUCT LIKE "TYVEK" ON EXTERIOR. <br />11. ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED INSULATION, INCLUDING ALL CAVITIES <br />ISOLATED DURING FRAMING. WIRING AND PLUMBING DO NOT COMPRESS INSULATION. <br />12. ATTIC ACCESS DOOR IS BAFFLED, WEATHERSTRIPPED, AND INSULATED. <br />13. MECHANICAL SPOT EXHAUST VENTILATION, DUCTED TO EXTERIOR, IS REQUIRED PER WSEC C403 <br />(80 cfm) AND KITCHENS (100 cfm). BACKDRAFT DAMPERS ARE REQUIRED. <br />14, SLAB ON GRADE IN HABITABLE AREA SHALL HAVE R-10 PERIMETER INSULATION (RIGID). <br />15. COMPLIANCE WITH VENTILATION AND INDOOR AIR QUALITY CODE WHOLE HOUSE VENTILATION PER WSEC C403 <br />W/ A 110 CFM FAN IN CLOTHES DRYER AREA <br />ALL WINDOWS SHALL HAVE VENT SLOT - AIR INLETS <br />16. EXTERIOR DOORS TO BE U.37 PER WSEC SECTION C402.1.4 <br />17. ALL GLAZING TO BE CERTIFIED AND LABELED WITH ITS U-VALUE BY AN INDEPENDENT AGENCY <br />LICENSED BY THE N.F.R.C. NFRC PRODUCT CERTIFICATION PROGRAM) <br />18. ALL LIGHT FIXTURES ARE TO BE SURFACE MOUNTED. <br />DIMENSIONS <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS EXISTING ON THE SITE PRIOR TO COMMENCING <br />FABRICATION AND ARCHITECT SHALL BE NOTIFIED OF DISCREPANCIES FOUND WITH INFORMATION GIVEN ON THE <br />DRAWINGS. <br />SHOP DRAWINGS <br />SHOP DRAWINGS OF FABRICATED ITEMS SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR FOR APPROVAL <br />PRIOR TO COMMENCING FABRICATION. <br />STUD SIZES AND SPACING <br />SEE SHEET S-1 <br />ATTIC VENTILATION <br />ALL ATTIC SPACES SHALL BE VENTED AS CALLED FOR IN 2015 IBC Ste. 1203,2 AND AS SHOWN ON ROOF <br />PLANS AND DETAILS <br />ATTIC SEPARATION <br />ALL ATTICS SHALL BE SEPARATED INTO AREAS AS CALLED FOR IN 2015 IBC SEC. 718.4 <br />SEE ROOF PLANS AND ROOF FRAMING PLANS FOR LOCATION. <br />LABELED DOORS <br />,ALL DOORS THAT ARE CALLED OUT TO BE LABELED SHALL HAVE A LABEL ON THE DOOR AND JAMB FROM A <br />NATIONALLY RECOGNIZED TESTING AGENCY. <br />FLAME SPREAD RATING <br />LIVING UNITS AND ROOMS CLASS C <br />PER 2015 IBC QIjAPTER 8, INCLUDING TABLE 803.11 <br />FLAME SPREAD RATING <br />1. ALL UNITS ARE HEATED BY ELECTRIC HEAT. <br />2. ALL COMMON AREAS ARE HEATED/ COOLED BY GAS FIRED UNITS. <br />SIGNAGE REQUIREMENTS <br />1. FLOOR IDENTIFICATION SIGNAGE <br />A SIGN SHALL PROVIDE AT EACH FLOOR LANDING IN EXIT EN( LOSURES CONNECTING MORE THAN THREE STORIES <br />DESIGNATING THE FLOOR LEVEL, THE TERMINUS OF THE TOP AND BOTTOM OF THE EXIT ENCLOSURE AND THE <br />IDENTIFICATION OF THE STAIR. THE SIGNAGE SHALL ALSO STATE THE STORY OF, AND THE DIRECTION TO, THE EXIT <br />DISCHARGE. THE SIGN SHALL BE LOCATED <br />E 5 FT ABOVE THE FLOOR LANDING IN A POSITION THAT IS READILY VISIBLE <br />WHEN THE DOORS ARE IN THE OPEN AND CLOSED POSITIONS. FLOOR LEVEL IDENTIFICATION SIGNS IN TACTILE LETTERS <br />COMPLYING WITH ICC A117.1 SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING ADJACENT TO THE DOOR LEADING <br />FROM THE ENCLOSURE INTO THE CORRIDOR TO IDENTIFY THE FLOOR LEVEL. <br />STAIRWAY IDENTIFICATION SIGNS SHALL BE" <br />1, MINIMUM SIZE OF 18 IN BY 12 IN <br />2. LETTERS SHALL BE A MINIMUM OF 1.5 INCHES IN HEIGHT. <br />3. THE NUMBER DESIGNATING THE FLOOR LEVEL SHALL BE A MINIMUM OF 5 IN IN HEIGHT, LOCATED IN THE CENTER, <br />OF THE SIGN. <br />4. ALL OTHER LETTERING AND NUMBERS SHALL BE A MINIMUM OF 1 IN HIGH. <br />5. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NONGLARE FINISH. SHALL CONTRAST WITH THEIR BACKGROUND, <br />WITH EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />2. CORRIDOR EXIT TO STAIRS <br />A TACTILE SIGN STATING "EXIT" SHALL BE PROVIDED ADJACENT TO EACH EXIT TO A STAIRWAY SEE SHT AO.4 <br />GENERAL LIGHTING REQUIREMENTS <br />1. 75% HIGH EFFICIENCY LIGHTING IS REQUIRED IN ALL RESIDENTIAL SPACES. <br />COMMERCIAL LIGHTING CONTROLS <br />1. FOR ALL INTERIOR COMMERCIAL AND COMMON AREAS (EXCLUDING EGRESS PATHWAYS), LIGHTING CONTROLS SHALL <br />BE PROVIDED SO AS TO COMPLY WITH SECTION C405 OF THE 2015 WASHINGTON STATE ENERGY CODE - INCLUDING <br />THE USE OF AUTOMATIC TIME SWITCHES, OCCUPANCY SENSORS AND DAYLIGHT SENSING DEVICES. <br />2. ALL EGRESS PATHWAYS (INCLUDING EXIT DISCHARGE) SHALL BE ILLUMINATED 24 HOURS PER DAY. <br />3. EXTERIOR LIGHTING SHALL BE CONTROLLED EITHER BY PHOTO SENSOR OR ASTRONOMIC TIME SWITCH, IN <br />COMPLIANCE WITH SECTION C405.2.7 OF THE 2015 WASHINGTON STATE ENERGY CODE. <br />BARRIER -FREE, HANDICAP ACCESSIBILITY PER APPLICATION SECTIONS OF IBC CHAPTERS 10 & 11 <br />IBC APPENDIX E, SECTIONS E101 THRU E107; BCC/ANSI A117.1-2009, WASHINGTON STATE AMENDMENTS PER WAC 51-50 <br />Q) <br />LLJ <br />LLJ <br />n <br />Q <br />Lu <br />�' <br />u-j <br />CL <br />0 <br />LIU <br />LL <br />LLJ <br />12 <br />Lu <br />Q) <br />Lu <br />i <br />C) <br />0AHO <br />ONTAN, <br />CALiFORNIA <br />COLORADO <br />NEVADA <br />NEBRASKA <br />UTAH <br />U <br />iiI <br />SOUTH <br />TL-921 REGISTERED <br />ARCHITECT <br />CHARLES E. MORG"s <br />STATE OF WASHINGTON <br />DATE17 DEC 19 <br />01 <br />,+I <br />BLDG, PERMIT 1 I APB �� <br />RESUBMITTAL <br />BLDG. PERMIT <br />RESUBMITTAL013 MAY 20 <br />SHEET <br />kill `1111111111 <br />