STRUCTURAL NOTES <br />POST TENSIONING NOTES <br />SHOTCRETE NOTES <br />(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) <br />(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) <br />(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) <br />WOOD I -JOISTS <br />GENERAL <br />CONCRETE <br />GENERAL NOTES <br />WOOD I -JOISTS, MANUFACTURED BY THE TRUS JOIST CORPORATION SHALL RE SIZED AND DETAILED TO FIT THE <br />1. TYPICAL DETAILS AND NOTES ON THESE SHEETS SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED <br />1. DESIGN AND CONSTRUCTION SHALL RE IN ACCORDANCE WITH ACI CODES AND SPECIFICATIONS. ALL CONCRETE <br />ALL SHOTCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE IBC SECTION 1910, AMERICAN CONCRETE <br />DIMENSIONS AND LOADS INDICATED ON THE PLANS. ALL DESIGN SHALL BE IN ACCORDANCE WITH THE ALLOWABLE <br />OTHERWISE. CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR <br />SHALL DEVELOP THE SPECIFIED COMPRESSIVE STRENGTH (F'C) WITHIN 28 DAYS. ALL CONCRETE SHALL BE STONE <br />INSTITUTE (ACI) 506R GUIDE TO SHOTCRETE, ACI SPECIFICATIONS FOR SHOTCRETE, AND ACI 516.411 GUIDE FOR THE <br />VALUES AND SECTION PROPERTIES ASSIGNED BY THE BUILDING CODE. <br />SIMILAR CONDITIONS. ALL WORK AND CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES, <br />AGGREGATE 3/4" MAXIMUM AGGREGATE SIZE (ASTM NO. L-67) THE USE OF FLY ASH IS PERMISSIBLE, SEE NOTE <br />EVALUATION OF SHOTCRETE, <br />REGULATIONS AND SAFETY REQUIREMENTS, <br />#8 BELOW, <br />PROVIDE TEMPORARY BRACING UNTIL SHEATHING AND PERMANENT BRACING IS INSTALLED. MANUFACTURER <br />A PRE -CONSTRUCTION MEETING WITH THE CONTRACTOR, SPECIAL INSPECTOR, AND BUILDING OFFICIAL IS <br />SHALL PROVIDE ALL SPECIALTY ITEMS REQUIRED FOR A COMPLETE INSTALLATION OF JOISTS. INSTALL PER <br />2. DISCREPANCIES: THE CONTRACTOR SHALL INFORM THE ENGINEER, IN WRITING, DURING THE BIDDING PERIOD OF <br />2. INSERTS: SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZES AND LOCATIONS OF HOLES, SLEEVES, <br />REQUIRED TO DISCUSS AND REVIEW THE SHOTCRETE PROCEDURES, WHICH SHALL INCLUDE THE LIFT HEIGHT, <br />MANUFACTURER'S RECOMMENDATIONS. <br />ANY DISCREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS OR OF ANY <br />REGLETS, MASHERS, BOLTS, NOTCHES, DRIPS, ETC, SEE STRUCTURAL DRAWINGS FOR EMBEDDED INSERTS, AND <br />NOZZLER APPROVAL, NOZZLER'S ASSISTANT (BLOW PIPE OPERATOR) APPROVAL, EQUIPMENT, METHOD OF TAKING <br />PRE -MANUFACTURED WOOD TRUSSES <br />VARIATIONS NEEDED IN ORDER TO CONFORM TO CODES, RULES AND REGULATIONS. UPON RECEIPT OF SUCH <br />INFORMATION, THE ENGINEER WILL SEND WRITTEN INSTRUCTIONS TO ALL CONCERNED. ANY SUCH <br />ANCHORS IN CONCRETE. <br />COMPRESSION TEST SAMPLES, DESIGN MIX, SLUMP, AND PRE -CONSTRUCTION TESTING. <br />WOOD TRUSSES SHALL BE SIZED AND DETAILED TO FIT DIMENSIONS AND LOADS INDICATED ON THE PLANS. ALL <br />DISCREPANCY, OMISSION OR VARIATION NOT REPORTED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, <br />AND WORK SHALL BE PERFORMED IN A MANNER AS DIRECTED BY THE ENGINEERS, <br />3, ADMIXTURES SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL, CALCIUM CHLORIDES SHALL NOT BE <br />PERMITTED IN ANY CONCRETE OR GROUT. <br />ANY SHOTCRETE COMPRISED OF COARSE AGGREGATE SHALL NOT USE COARSE AGGREGATE EXCEEDING 3/4 INCH. <br />P <br />INDOOR <br />11 <br />s. a - <br />Awl <br />1101will Tula <br />! h x - s rx !gA . <br />rli'1tTY�; TsIC) l Yl <br />1. BEARING WALL FRAMING <br />REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR & WINDOW HEADERS NOT CALLED OUT ON THE PLANS. <br />ALL COLUMNS NOT CALLED OUT OTHERWISE SHALL BE TWO STUDS. <br />2. WALL BASE PLATE ON CONCRETE <br />f <br />ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE <br />PLANS, EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING <br />FRAMING WITH 10d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS, <br />THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH <br />FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE, <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS <br />ONLY WILL NOT SATISFY THIS REQUIREMENT. <br />Mum <br />A) THEY SHALL BE NOT LARGER THAN ONE THIRD THE OVERALL THICKNESS OF THE SLAB IN WHICH THEY ARE <br />EMBEDDED. <br />B) THEY SHALL BE SPACED NOT CLOSER THAN THREE DIAMETERS OR WIDTHS ON CENTER, AT ELECTRICAL <br />ROOMS OR CONGESTED AREAS WHERE MINIMUM SPACING CANNOT BE ACHIEVED USE #5 AT 12" O.C. <br />EACH WAY EXTENDING A MINIMUM OF TWO FEET BEYOND CONGESTION. MORE THAN ONE LAYER OF <br />CONDUIT IS NOT PERMITTED UNLESS APPROVED BY THE ENGINEER. <br />C) THEY SHALL NOT IMPAIR SIGNIFICANTLY THE STRENGTH OF CONSTRUCTION. <br />D) THEY ARE NOT EXPOSED TO RUSTING OR OTHER DETERIORATION. <br />E) THEY ARE OF UNCOATED OR GALVANIZED IRON OR STEEL NOT THINNER THAN STANDARD SCHEDULE 40 <br />STEEL PIPE. <br />8. CONCRETE MIX DESIGN SHALL COMPLY WITH THE FOLLOWING: <br />REINFORCING BARS USED IN SHOTCRETE CONSTRUCTION SHALL USE NO. S OR SMALLER BARS, NO.6 BARS AND <br />LARGER MAY BE USED IF DEMONSTRATED THROUGH PRE -CONSTRUCTION TESTS THAT ADEQUATE ENCASEMENT OF <br />LARGER BARS CAN BE ACHIEVED. <br />! <br />- z <br />ABBREVIATIONS <br />(A) <br />--- <br />ABOVE <br />�KSI <br />I <br />GLB <br />GLUE -LAMINATED BEAM <br />AB` <br />ANCHOR BOLT - <br />HORIZ--- <br />� HORIZONTAL <br />ALT -ALTERNATE--- <br />-- --- <br />KP <br />- ----- ---- <br />KING POST <br />ARCH <br />-- ---- <br />�A CHITECT <br />--- <br />KIP PER SQUARE INCH <br />(B) <br />BD <br />BELOW <br />BAR DIAMETER <br />L <br />ANGLE — <br />MECH <br />MECHANICAL <br />BLKG <br />_ _ <br />7 BLOCKING - - -- <br />I—M F <br />--MOMENT FRAME - ------ <br />IM <br />BOT <br />BEAM <br />BOTTOM <br />MTL <br />METAL <br />NS <br />NEAR SIDE --_ - - <br />BRNG <br />BEARING <br />OC <br />ON CENTER <br />BTWN <br />BETWEEN <br />OPP <br />OPPOSITE <br />CJP <br />COMPLETE JOINT PENETRATION - --- <br />PL ----�-PLATE <br />--- - <br />-CL R <br />CLEAR---- <br />PLCS <br />-PLACES <br />CMU - <br />COL <br />CONC �-CONCRETE--- <br />--.--_- <br />CONCRETE MASONRY UNIT <br />COLUMN <br />- - ----- <br />---� <br />PSI <br />--- <br />� POUNDS PER SQUARE INCH <br />�PSF <br />POUNDS PER SQUARE FOOT <br />P/T <br />POST TENSIONED <br />CONK -- <br />CONNECTION —� <br />i PT ------ <br />PRESSURE TREATED ------ -- <br />CONT <br />� CONTINUOUS ---------- <br />REINF ----� <br />�_REQ'D -- <br />REINFORCING---------^- ---- <br />REQUIRED - - -- <br />COORD <br />jj COORDINATE <br />--- - <br />DBL <br />DOUBLE <br />SCHED <br />SCHEDULE <br />LET <br />DETAIL - <br />Sim --- <br />SIMILAR ' <br />DIA ----� <br />DiAMETER--------- <br />-SOG-----1--SIB <br />ON GRADE -- --- <br />DIM--DIMENSION <br />-- <br />- <br />STD -- <br />F STANDARD <br />DiR <br />DIRECTION - ---- - <br />STIFF <br />F ST EFFIST NER - ------ -- <br />EA ---- <br />EACH -- <br />STL <br />STEEL -------------- <br />ELEV-- <br />ELEVATION �- <br />SYMM <br />SYMMETRICAL <br />ES <br />-- <br />EACH SIDE <br />SW <br />SHEARWALL <br />EX <br />-- <br />1- EXISTING <br />-- <br />TOC <br />-i-- <br />TOP OF CONCRETE <br />EXP <br />-- ----- ---� <br />EXPANSION----_ <br />------) <br />TOS <br />TOP OF STEEL --� - <br />FLR <br />-- <br />- <br />FLOOR <br />TOW <br />TOP OF WALL <br />FDN <br />FOUNDATION <br />TYP <br />TYPICAL --- <br />FTG <br />FOOTING <br />UNO <br />UNLESS NOTED OTHERWISE <br />FS —FAR <br />--- -- <br />SIDE <br />VERT <br />VERTICAL <br />GC <br />GENERAL CONTRACTOR <br />WF <br />WIDE FLANGE - <br />05/ i4/ 20 <br />�I <br />- (I <br />Y <br />{ <br />M.y{ <br />I <br />f <br />° n <br />i <br />I <br />r <br />Ow <br />01" <br />In <br />SHEET: <br />