My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2621 ROCKEFELLER AVE 2019 Plans 2022-12-01 (2)
>
Address Records
>
ROCKEFELLER AVE
>
2621
>
Plans
>
2621 ROCKEFELLER AVE 2019 Plans 2022-12-01 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:08:09 AM
Creation date
2/17/2022 3:31:28 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2621
Permit
PW1912-046
Year
2019
Notes
NEW ROCKEFELLER SQUARE MULTI FAMILY (30) UNITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W 1/4, SEC. 20, T. 29 X, R. 05 E. W.M. <br />S.NOHOMISH COUNTY, WASHI GTON <br />CITY OF EVER= SANITARY SEWER NOTES <br />A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS AND <br />WSDOT/APWA STANDARD SPECIFICATIONS. <br />B. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, CONCEALED OR PUT INTO <br />USE UN77L IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY INSPECTOR. <br />C. APPROXIMATE LOCA7IONS OF EXIS77NG UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE <br />RECORDS AND ARE SHOWN FOR CONVENIENCE THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY AD017IONAL UTILITIES <br />NOT SHOWN. IF CONFLICTS WITH EXIS71NG UTILITIES ARISE DURING CONSTRUCTION, THE <br />CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY CHANGES REQUIRED <br />SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO COMMENCEMENT OF RELATED <br />CONSTRUCTION ON THE PROJECT. <br />D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS MUST <br />BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING CONSTRUCTION. <br />CITYOFEVERETT WATER NOTES <br />A. NO CONNEC77ON TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN <br />APPROVED BACKFLOW PREVEN77ON DEVICE PRIOR TO SA775FACTORY FLUSHING, 7ES77NG, <br />DISINFECTION, AND RECEIPT OF SA77SFACTORY BACTERIOLOGICAL TEST RESULTS. <br />B. CONNEC77ONS TO AND TAPS ON EXIS77NO MAINS WILL BE MADE BY THE PUBLIC WORKS <br />DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBLIC WORKS DEPARTMENT SHALL BE <br />GIVEN AT LEAST 5 BUSINESS DAYS N0710E FOR EACH CONNECTION, THE PUBLIC WORKS <br />DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND 77ME AT WHICH THE <br />CONNEC77ON SHALL BE MADE. <br />C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS, <br />D. A PRE -CONSTRUCTION MEE77NG SHALL BE HELD WITH THE CITY PRIOR TO THE START OF <br />CONS7RUC7ION. THE CITY OF EVERETT PUBLIC WORKS CONSTRUCTION DIVISION MUST BE <br />NO77FIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONS7RUC770N. <br />E. THE DEVELOPER OR THE DEVELOPERS AUTHORIZED AGENT SHALL N077FY THE PUBLIC <br />WORKS DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS <br />DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VER71CAL SEPARA77ON <br />BETWEEN POTABLE AND NON -POTABLE CONVEYANCE SYSTEMS. <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC WORKS DEPARTMENT <br />PERSONNEL ONLY. ALL VALVES, NEW AND EXIS77NG, SHALL BE ACCESSIBLE AT ALL 77MES, <br />PARTS <br />NOTES <br />A. <br />UL-FM LISTED SOFT SEATED WA STATE APPROVED <br />1. TEE AND GATE VALVE REQUIRED ON MAIN. <br />B <br />DOUBLE CHECK DETECTOR VALVE ASSEMBLY WHICH <br />J <br />MUST BE INSTALLED IN THE SAME ORIENTATION FOR <br />2. SINGLE DETECTOR CHECKS ARE NOT APPROVED <br />`z <br />WHICH IT WAS APPROVED. ASSEMBLY TO INCLUDE; <br />BACKFLOW PREVENTION DEVICES. <br />INTERIOR WALL <br />TEST COCKS, 3/4" BRASS OR COPPER BYPASS WITH <br />ca <br />z 0- <br />IN -LINE VALVES AND A 5/8" REMOTE METER. METER <br />3. ASSEMBLY REQUIRES CERTIFICATION UPON <br />C <br />TO READ IN CUBIC FEET, AND BE REMOTED TO AN <br />INSTALLATION, AND RECERTIFICATION ANNUALLY BY <br />0 <br />B <br />N <br />EXTERNAL WALL OF BUILDING METER BOX. <br />OWNER. <br />U <br />B. <br />o <br />UNI-FLANGE WITH SET SCREWS OR M1 x FL ADAPTER <br />WITH MEGALUG RESTRAINT FOR BOTH UPSTREAM <br />4. ALL TEST COCKS MUST HAVE BRASS PLUGS. <br />tu <br />AND DOWNSTREAM OF ASSEMBLY. <br />5. MAXIMUM HEIGHT OF ASSEMBLY FROM FLOOR IS <br />FIVE FEET UNLESS AN OSHA APPROVED PLATFORM IS <br />® C. <br />DUCTILE IRON PIPE (SIZED AS REQUIRED) CLASS 52. <br />PROVIDED. <br />D. <br />TWO GALVANIZED ADJUSTABLE PIPE SUPPORTS FOR 2 <br />6. ALL DIMENSIONS ARE MINIMUM CLEARANCE <br />1/2" DIA AND LARGER PIPE. <br />REQUIREMENTS. <br />A E. <br />A SUFFICIENTLY SIZED FLOOR DRAIN OR WALL <br />7. FIRE DEPARTMENT PUMPER CONNECTION MUST BE <br />F <br />FOOTING DRAIN MUST BE PROVIDED IN THE SAME <br />DOWNSTREAM OF ASSEMBLY. <br />ROOM. DRAIN TO SLOPE TO DAYLIGHT OR CONNECT <br />TO STORM DRAIN SYSTEM. <br />8, THE OSY VALVE CAN NOT BE USED AS A POST <br />INDICATOR VALVE. (THESE ARE ONLY PART OF THE <br />F. <br />EXTERNAL DOOR WITH KEY IS REQUIRED. EITHER A <br />BACKFLOW ASSY.) <br />LOCKSET IN THE DOOR HARDWARE OR A KEY VAULT <br />(I.E. SUPRA S.S.) WITH A 15/8" DIAMETER X 1 1/8" <br />PLAN <br />LENGTH MORTISE CYLINDER. MORTISE CYLINDER <br />MUST ACCEPT THE CITY STANDARD "BEST" LOCKING <br />SYSTEM. THE WIDTH AND HEIGHT OF THE DOOR(S) <br />MUST EXCEED THE WIDTH AND HEIGHT OF THE <br />ASSEMBLY. CLEARANCE BOTH INSIDE AND OUTSIDE <br />CEILING <br />ROOM MUST BE SUFFICIENT TO REMOVE ASSEMBLY <br />INTACT. THE ASSEMBLY MUST BE FULLY ACCESSIBLE <br />(2FT MIN HORIZONTAL CLEARANCE TO ALL WALLS <br />AND OR EQUIPMENT) FOR TESTING AND REPAIRS. <br />G. <br />FLUSHING CAPABILITIES MUST BE PROVIDED WITH A <br />2" FLUSHING LINE DOWNSTREAM OF ASSEMBLY TO <br />a <br />OUTSIDE OR SUFFICIENTLY SIZED INTERNAL DRAIN. <br />z <br />6" MIN <br />H. <br />WHERE ASSEMBLY IS TO BE LOCATED ABOVE <br />C <br />EXTERNAL GROUND LEVEL, ALL BENDS REQUIRED TO <br />Z <br />r <br />LOWER INLET PIPE TO PROVIDE REQUIRED EXTERNAL <br />Z <br />FLOW <br />GROUND COVER SHALL BE FLANGE FITTINGS OR BE <br />'"'-^-- <br />FITTED WITH HORIZONTAL AND VERTICAL THRUST <br />w <br />z <br />RESTRAINTS. <br />o <br />G I. <br />THE ROOM SHOULD BE INSULATED WITH R-19 <br />u <br />w <br />INSULATION OR GREATER AND HEATED TO ABOVE <br />TYPICAL WHEN FIRE ROOM IS LESS THAN 70' FROM MAIN <br />B <br />FLOOR <br />FREEZING. ONLY CONSTRUCTION MATERIALS THAT <br />z <br />CAN WITHSTAND OCCASIONAL SUBMERGENCE WILL"""""EVERETT <br />PUBLIC WORKS <br />8 <br />z <br />a <br />BE ALLOWED. <br />WAS H I NGTON DEPARTMENT <br />8 <br />D <br />c"Bnglr Settien Manager CADManager Drewn By Cur�tRev Opte <br />RYAN SASS R. HEFTI pAUL WILHELM WR& 1 14/2020 <br />a <br />ELEVATION <br />DOUBLE CHECK DETECTOR STANDARD DRAWING Ne. <br />VALVE ASSEMBLY (DCDA) 523 <br />2" & LARGER SERVICE INSIDE A BUILDING <br />1 DOUBLE CHECK DETECTOR VALVE ASSEMBLY <br />C4, 0 NOT TO SCALE <br />NOTES <br />C A 1. ALL TEST COCKS MUST HAVE BRASS PLUGS. <br />2. TEST COCKS MUST FACE UP OR SIDEWAYS WHICH <br />'51,t w4 _ x , EVER IS MORE ACCESSIBLE. <br />3. PROVIDE NON -SLIP SURFACE ON ACCESS HATCH <br />Z IF VAULT IS LOCATED IN PEDESTRIAN WALKWAY. <br />;FLOWOW lox <br />3" MIN ' <br />PARTS <br />p` A. WA STATE APPROVED DOUBLE CHECK VALVE <br />ASSEMBLY. <br />B. IN NON -TRAFFIC AREAS USE. <br />PRECAST CONCRETE VAULT (UTILITY VAULT CO <br />233-LA, OR APPROVED EQUAL) OR PLASTIC VALVE <br />PLAN BOX (UTILITY VAULT CO 1324-12L OR APPROVED <br />EQUAL) <br />C. IN TRAFFIC AREAS: <br />A TRAFFIC LOADED BOX MUST BE USED AND <br />B A LOCATION APPROVED BY THE THE CITY OF <br />z z <br />E- LU EVERETT PRIOR TO INSTALLATION. <br />a <br />zQa <br />Uj D. IF A DAYLIGHT DRAIN CANNOT BE PROVIDED THERE <br />00 a > MUST BE A 4" MIN LAYER OF FREE DRAINING <br />GRAVEL AT THE BOTTOM OF BOX. <br />If <br />E. ANGLES MAY BE IN OR OUT OF BOX SO LONG AS <br />- SUFFICIENT ROOM IS ALLOWED AT EACH END FOR <br />VALVE OPERATOR AND DCVA REPAIR OR <br />MAINTENANCE. <br />cr E <br />L1I <br />o <br />> <br />M <br />0 <br />V <br />z <br />GG <br />0 <br />g <br />z <br />N FLOW <br />0 <br />o <br />� <br />O <br />a <br />F <br />0 <br />CITY OF EVERETT <br />z <br />E PUBLIC WORKS DEPARTMENT <br />o <br />�/ /� as <br />RttHEFTI�e PAU1. wILHELM Oraw�WRR arrest aew wee <br />ELEVATION 12 30 201 <br />1;1TmeIIYANSASS <br />DOUBLE CHECK VALVE STANDARD DRAWING N. <br />�g <br />D ASSEMBLY 520 <br />DCVA FOR 2-1/2" & SMALLER SERVICE <br />DOUBLE CHECK DETECTOR VALVE ASSEMBLY <br />NOT TO SCALE <br />Know what's below. <br />Call before you dig. <br />UTILITY CONFLICT NOTE. <br />CAUTION• <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, <br />DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE <br />PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL <br />AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE <br />CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING <br />UTILITIES AT LOCATIONS OF NEW UTILI7Y CROSSINGS TO PHYSICALLY VERIFY <br />WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN <br />ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND <br />ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR <br />SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL <br />PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />
The URL can be used to link to this page
Your browser does not support the video tag.