Stwe!cturai Notes- <br />Code: <br />Design is in accordance with the 2015 International Building Code (I B.C.) as amended by the <br />local building department. <br />Live. Load: <br />Roof 25psf <br />Floor 40psf <br />Deck 60psf <br />Lateral: <br />Wind Exposure B, 85mph / 110mph (Uit) / Wind perASCE 7-10, Section 28.6.3. <br />seismic Site Class D. Seismic per ASCE 7-10, Simplified Lateral Force System, <br />Section 12.14.8. <br />Fouindadons: <br />Extend footings to firm undisturbed soil, assumed bearing capacity of 1,500psf. Aii exterior <br />footings shall extend a minimum of 24 inches below adjacent exterior grade, <br />Cast -in -place Concrete* <br />F'c=3,000psi @ 28 days. Minimum 5% sacks of cement per cubic yard of concrete and maximum <br />of 6% gallons of water per S. sack of cement. No special inspection required. Concrete shall <br />com ply with ACI 318-14 Section 26.4.2.1. Maximum slump is 4 inches. All phases of work <br />pertaining to the concrete construction shall conform to buillding code requirements for <br />reinforced concrete. All reinforcing steel, dowels, anchor bolts, and other in erts shall be <br />seci,rre3d in position prior to pouring concrete. Anchor bolts for pressure treated sill plates to <br />foundation walls are to be % inch diameter with 7 inch minimum embedment into concrete and <br />maximum spacing of 36 inches on center. lVinimurn 2 bolts per sill plate piece. Once bolt to be <br />placed within 6 inches of each end of the sill plate. Dipped galvanized connectors shall conform <br />to ASTM Standard 153 and hot dipped galvanized connectors shall conform To ASTM A653m, <br />Class G-135. Stainless steel fasteners and connectors; shall be type 304 or 3L6. Simpson product <br />finishes corresponding to these requirements are to be Zmax (Hot Dipped Galvanized) and SST <br />300 (Stainless Steel). Fasteners for pressure treated and fire -retardant treated wood shall be <br />Zmvx (Hot Dipped Galvanized) G185. <br />&ek11.fGrV'nF Steel, <br />All reinforcing steel shall be placed in conformance with the building code requirements for <br />reinforced concrete and the manual of standard practice for reinforced concrete construction <br />by CIRSL Deformed reinforcing steel bars shall conform to ASTM A-615 Grade 40 for #5 and <br />smaller reinforcement and Grade 60 for #6 and larger. All reinforcing bar bends shall be made <br />cold with a minimum radius of 6 bar diameters (19 inches minimum). Corner bars (24 inches <br />minimum) shall be provided for all horizontal reinforcement. Lap all bars a minimum of 48 bar <br />diameters unless noted otherwise. Unless noted otherwise on tile drawings, reinforcing steel <br />shall have the following minimum cover: <br />Concrete cast against earth 3-inches <br />Concrete exposed to earth or weather: <br />#6 through #18 bars 2-Inchl <br />#5 and smaller bars 1%-inches <br />S_trtkc_turall —Ti-ber. <br />All lumber shall conform to WWPA grading rules for western lumber, latest edition. Provide cut <br />washers under all nuts and bolts bearing against wood. Ali wood in, direct contact with concrete <br />or earth shall be pressure treated in accordance with AWPA Ul and M4 standards. All structural <br />lumber shall be as follows:: <br />2N: deck joists Herri Fb = 850psi <br />4x beams Doug-Fir/Larch #2 Fb = 850psi <br />6x beams Doug-Fir/Larch #2 Fb = 850psi <br />Lurriber not noted Hem -Fir #2 Fb = 850psi <br />Miscellaneous hangers to be Simpson" or approved equal. All hangers shall 1,3e fastened to <br />wood with proper nails. All holes shall be filled. Madiine bolts to be A-307. AH nails shail be <br />common wire nails. Nailing sihall be in accordance w'lth the current internal Building Code <br />schedule. <br />Structura0 Laminated Lumbi ,tr �Grade2.®fl: <br />Flo z,. 2,600psi <br />E = 2,000,000psi <br />Fv = 285psi <br />GE,u--Larnnated 71mber- <br />Larninated timber shall be douglas-fir/larch Idin dried. Stress grade combination of 24F-V4 for <br />sh-ripile spans and 24F-VS fore continuous and cantilevered spans. <br />LBaring Well] Frarning: <br />All door and window headers not specific2ily called out on the plans shall be (2) 2X8 Hem -Fir #2 <br />with one cripple and one st.id at each and for openings up to 4 feet wide. All columns not <br />specifically cailed out on the plans shall be (2) studs spiked together with 12d nails at 12 inches <br />on -center (staggered). Provide (2) layers of building paper between wood and concrete. Walls <br />shall have a single bottom plate and double too plate. End nail top plates and bottom plates to <br />eadii stud with (2) 16d nails, Face nail double top pl;,,te with 16d nails at 10 inches on -center. <br />Lap and face nail piates with (2) 16d nails at each splice, corner intersection. Stagger splices a <br />minimum of 48 inches. <br />2 Lioc.mr Sheathling. <br />Sheathing shall be Y4 inch tongue and groove APA rated sheathing with a minimum span rating <br />of48/24. Install sheathing vil long dimension perpendicularta supports. Unless noted <br />otherwise nail sheathing v&h So common nails at 6 inches on -canter at all supported panel <br />edges and 10 inches on -center at all intermediate supports. The floor sheathing shall be glued <br />to the joist and the tongue <:,ind groove joints with an approved adhesive. <br />Sheathing shall be 7/lo inch PIPA rated sheathing vvit[,, a minimum span rating of 24/0. Panel end <br />Joints shall occur at supports. Nail panel edges with So common nails at 6 inches on -center at all <br />supported panel edges and 10 inches on -center at all intermediate supports unless noted <br />otherwise on the structural plans. <br />jLogf Sheathing. - <br />Sheathing shali be 711c, inch APA rated sheathing witl­� a minimum span rating of 32/16. lnstall <br />si,iieathing, with long dimension perpendicular to Supports. Panel end joints shall occur at <br />supports. Nail panel edgesvilth So common nails at 4 inches on -center at all supported panel <br />edges and 10 inches on -center at all intermediate supports unless noted otherwise on the <br />structural Plans. <br />Root Trusses. <br />Trusses shall be plant fabricated with douglas-fir/larch or herl lumber. Truss manufacturer <br />shall submit shop drawings and calculations stamped, signed and dated by a Washington State <br />Hcensed Structural Engineer. Submit truss dravving to the engineer of record and building <br />department for review and approval prior to fabrication. Roof trusses shall be designed as attic <br />trusses without storage. Manufacturers installation instructions shalt be available on the job <br />site at the throe of inspection, for the inspectors use and reference. <br />A. The truss live loadhl shall be per IRC Section 301.5 and table 301.5, a=_speclally noting <br />footnotes B and G. <br />S. The truss design shad be per lRC Sections 50.,'?.11.1 and 802.10.2, especially indicating <br />the truss design and manufacturing shall be per ANSI/TP11. <br />CThe truss temporary and permanent bracing shall be per IRC Sections 502,11.2 and <br />802.103 as well as the Truss Plate Institute's Building Coin ponent Safety information. <br />0. Truss alterations shall not occur unlesstheapproval of a design professionall as <br />indicated in IRC Sections 502.12.3 and 302.10.4. <br />IF THIS PLAN IS NOT ON 18x24 PAPER, IT HAS BEEN SC-ALED ACCORI.,,)INGLY <br />SHEAR WALL SCHEDULE <br />Shear <br />Wall <br />Designation <br />Nail <br />Size <br />s Nail Spacing <br />Allowable Shear <br />Hem-1Eir#2 <br />Lbs./Ft. <br />Edges <br />Studs <br />Top/Btm <br />Plate <br />Blocking <br />Reci'd. <br />PI-6 <br />® <br />61IN <br />12"' <br />Ou <br />Yes <br />210 <br />P1-4 <br />8d <br />4"' <br />12" <br />4uo <br />Yes <br />310 <br />P1-3 <br />8d <br />315 <br />12" <br />3"0 <br />Yes <br />400 <br />PI-2 <br />8d <br />2" <br />12" <br />2uv <br />Yes <br />525 <br />P2-3 <br />P2-2 <br />Bid <br />8d <br />3" <br />2"a <br />12"t <br />12" <br />Vu <br />2" <br />Yes <br />Yes <br />Soo <br />1,050 <br />snearwatl%jotes: <br />1.) Pl-* 7/16" APA rated Plywood or Orientated Strand Board (OSB) on one face of wall. <br />P2-* 7/16" APA rated Plywood or Orientated Strand Board (OSB) on each face of wall. <br />2.) For P1-3, PI-2, 1:12-3 and P2-2 shear wahs use 3x studs at adjoining panel edges. Nailing <br />shall be staggered. <br />3.) Nails shall be 8d common. (.131 inch diameter) <br />4.) Where Plywood is installed on both faces of wall plywood joints shall fall on separate studs <br />each side. <br />5.) All panel edges backed with 2 inch nominal framng for PI-6 and PI-4 shear walls. All panel <br />edges backed with 3 inch nominal framing for PI-3, P1-2, P2-3 and, P2-2 shear walls. install <br />panels either horizontally or vertically. Space nafi.,.'; 10" o.c. at intermediate supports. <br />6.) All anchor bolts shall be installed with hot dipped galvanized plate washers. <br />7.) Refer to foundation plan for ancilhor bolt size, spacing and mudsill/dirn conditions. <br />lil. 1, . - <br />1 -1, — <br />ffll�M M, <br />ISA"Afe X&, <br />44A 44� <br />If/"-- Sol <br />BQ <br />A Ovsiv VA <br />P41 7 7, o� <br />5 14 '1 ;1. <br />tI <br />2 �J FOUNDATION SECTION @ DOOR <br />V <br />SCALE: NONE <br />M1 <br />ME* <br />/ 61d -rot <br />69 <br />JIM! <br />aI J I <br />: & ae <br />4Ar 61 <br />'RI7, <br />5 SoT ;9�lPo CA�IAJ <br />C" <br />SCALE: NONE <br />05to <br />Kj <br />Co <br />< <br />> <br />0 <br />611 2 <br />z <br />E <br />00 <br />_C 0 <br />CD q <br />C <br />Ln <br />Lit <br />1,6 <br />CD <br />re <br />Z <br />Z <br />C) tl co <br />� <br />E <br />C CD <br />0 C' <br />1,D <br />Z <br />'6) <br />Z <br />X: M <br />(-X:, 3 <br />0 <br />E <br />Q) <br />TL4 <br />of <br />481 <br />0 <br />LA <br />Q) <br />> �A <br />oLn <br />,1— 4- Z <br />> <br />0 <br />= <br />CD (2) < <br />Z <br />Cj <br />ro <br />0112, �7171 Title0"011"N <br />Structural <br />Notes <br />and <br />Details <br />Douglas Almond <br />riqnal raven <br />05/26/2020 <br />ro�um <br />20-031-01 <br />Plan <br /><�> 01/12/2021 <br />Sheet: <br />SCALE: NONE <br />