Laserfiche WebLink
MAINTENANCE AREA <br />1/4" = I'—O" <br />EXISTING EXTERIOR <br />WALL <br />± 19'-0" TOP OF WALL PLATE 8 LABORATORY <br />PROVIDE 2 X WD. — <br />FIREBLOCKING WHERE <br />NEW WALL MEETS <br />EXISTING WALL, TYP. <br />± 0" LABORATORY MEZZANINE SUBFLR <br />EXTEND WALL DOWN TO — <br />NAIL DENSGLASS SHEATHING <br />REFER PARTITION TYPE I <br />SHEET A -I. USE 2 X 4 5 <br />IC O.C. WITH 2 X 4 TOP <br />AND BOTTOM PLATE TO <br />CREATE TRANSOM WALL <br />0'-0" TOP OF SHOP FLOOR <br />TOP OF EX. RIDGE <br />+ 28'-C T.O. EX. WALL PLATE <br />± 19'-0" TOP OF WALL PLATE a LABORATORY <br />VIC X 3 1/2" PRIMED <br />MDF CASING, TYP. <br />NEW DOOR 8 LABORATORY <br />REFER TO MEZZANINE LEVEL <br />PLAN <br />± W-O" LABORATORY MEZZANINE SUBFLR. <br />_* <br />EXISTING WD. FRAMED <br />GUARD/RAIL. 42" HIGH <br />PER 2015 IBC SECTION <br />1015.3 <br />EXISTING EXTERIOR <br />WALL <br />EXISTING WD. STAIR <br />0'-0" TOP OF SHOP FLOOR <br />HANDRAIL AT LEAST ON ONE <br />SIDE OF EXISTING STAIRS PER <br />2015 IEBC SECTION 805.9.1 <br />HEIGHT 8 36". CLEARANCE NOT <br />LESS THAN 1 1/2" FROM EXISTING <br />GUARD/RAIL PER 2015 IBC SECTION <br />101q.1. PROJECTION NOT MORE THAN. <br />4 1/2" AT OR BELOW HANDRAIL <br />HEIGHT PER 1014.8 <br />LENGTH OF NEW WALL: <br />2S% OF LENGTH OF NEW WALL: 3.56 FT <br />WIDTH OF (1) WINDOW: 3 FT. (LESS THAN 25%) <br />EXISTING PUMP MAINTENANCE <br />EXISTING BUILDING <br />— B.O. WINDOW/DOOR HEADER ®I <br />- NEW WINDOW. REFER TO <br />SHEET A-1 FOR SIZE <br />- TYP. CASING <br />- LINE OF EXISTING BOTTOM <br />OF RIM JOISTS <br />EXTEND DENSGLASS <br />SHEATHING 12" MIN. BELOW <br />DOUBLE TOP PLATE OF <br />EXISTING WALL <br />EXISTING MAINTENANCE SHOE <br />EXISTING WOOD FRAMED <br />WALL WITH PLYWOOD <br />SHEATHING <br />EXISTING CONC. SLAB 9 <br />EXISTING MAINTENANCE <br />SHOP/BUILDING <br />VA71ON <br />NEW WINDOW. REFER TO <br />SHEET A -I FOR SIZE <br />TYP. CASING <br />REFER TO PARTITION <br />TYPE I SHEET A-1 <br />(FIRE BARRIER) <br />EXISTING WOOD FRAMED <br />WALL WITH PLYWOOD <br />SHEATHING <br />NEW 23/32" THK. TOG <br />PLYWOOD SUBFLOOR <br />2X10Rill BID, <br />(2) 2 X 4 TOP PLATE <br />PROVIDE R-21 BATT <br />INSULATION IN BETWEEN <br />STUDS <br />REFER TO PARTITION — <br />TYPE I FOR NEW WALL <br />ASSEMBLY <br />NEW 15/32" THK. PLYWOOD <br />SHEATHING <br />EXIST. 23/32" THK. TAG — <br />PLYWOOD SUBFLR. GLUED <br />AND NAILED TO EXISTING <br />FLOOR JOISTS <br />EXISTING 2 X 12 <br />RIM BOARD <br />EXISTING PLYWOOD <br />SHEATHING <br />EXISTING WOOD FRAMED — <br />WALL WITH PLYWOOD <br />SHEATHING <br />1/4" = 11_01, <br />2X10816"O.C. <br />CEILING JOISTS WITH <br />2 X 10 SOLID BRIDGING <br />8 MIDSPAN <br />R-30 CEILING BATT <br />INSULATION <br />FIREBLOCKING NOTE: <br />IF NOMINAL 2" LUMBER IS <br />USED, BLOCK ENTIRE <br />OPENING HORIZONTAL AND <br />FILL GAP WITH FIREBLOCK <br />FOAM SEALANT <br />II FiRESLOCKING NOTE: <br />IF UNFACED FIBERGLASS <br />BAIT INSULATION IS USED <br />AS FIREBLOCKING, FILL <br />ENTIRE CROSS SECTION <br />OF WALL CAVITY TO A <br />MINIMUM HEIGHT OF 16" <br />MEASURED VERTICALLY <br />PACK TIGHTLY AROUND <br />OBSTRUCTIONS SUCH AS <br />PIPING AND CONDUIT <br />_J FIREBLOCKING SHALL BE — <br />PROVIDED IN CONCEALED <br />WINDOW TRIM/MOULDING SPACES HORIZONTALLY AT <br />PER OWNER EROFOSED LABORATORY INTERVALS NOT EXCEEDING <br />BASEBOARD PER 10 FEET PER 2015 IBC <br />OWNER —x C <br />SECTION 118.2.2 <br />EXISTING DOUBLE NEW R-30 BATT —/ EXISTING LEDGER —� <br />TOP PLATE INSULATION OR <br />SPRAY FOAM INSUL. <br />EXISTING 2 X 12 VNEW 5/8" TYPE "X" OR <br />IC O.C. WITH 2 X 12 "C" GYPSUM BOARD. <br />SOLID BRIDGING EXISTING �U�E MAINTENANCE REFER TO FLOOR/CEILING <br />MIDSPAN ASSEMBLY SHEET A-1 <br />� S E C T N <br />�"= <br />il/2 I —® <br />LINE OF EXISTING <br />HANDRAIL (BOTH <br />SIDES) OF EXISTING <br />STAIR <br />EXISTING GUARDRAIL <br />LINE OF EXISTING <br />RISERS AND TREADS <br />EXISTING EXTERIOR <br />WALL <br />FIREBLOCKING MATERIAL PER 2015 IBC <br />SECTION 118.2.1 <br />I. 2" NOMINAL LUMBER <br />2. 2 LAYERS OF I" NOMINAL LUMBER <br />WITH BROKEN LAP JOINTS <br />3. ONE 3/4" PARTICLEBD. WITH JOINTS <br />BACKED BY 3/4" PARTICLEBD. <br />4. ONE 23/32" WOOD STRUCTURAL PANEL <br />WITH JOINTS BACKED BY 23/32" WOOD <br />STRUCTURAL PANEL <br />5, 1/2" GYPSUM BOARD <br />L 1/4" CEMENT -BASED MILLBOARD <br />T BATTS OR BLANKETS OF MINERAL WOOL, <br />MINERAL FIBER SECURELY RETAINED IN PLACE <br />_ ± 19'-0" TOP OF WALL PLATE 1� LABORATORY <br />2 X 10 BLOCKING <br />PROVIDE FIRE13LOOK FOAM <br />SEALANT AT ANNULAR SPACE <br />AROUND VENTS, PIPES AND <br />DUCTS AT CEILING AND FLOOR <br />LEVELS PER 20I5 IBC SECTION <br />118.2.5 <br />REFER TO PARTITION <br />TYPE 2 FOR NEW WALL <br />ASSEMBLY <br />2X4'a16"O.C.FUR OUT <br />STUD WALL WITH BOTTOM <br />PLATE AND DOUBLE TOP <br />PLATE <br />OPTIONAL BATT INSULATION <br />IN BETWEEN WALL STUD <br />± II'-O" LABORATORY MEZZANINE SUBFLR. <br />TYP. FIREBLOCKING <br />FIBERGLASS INSULATION <br />OR 2" NOMINAL LUMBER <br />WITH FOAM SEALANT. <br />SEE NOTE ABOVE <br />EXISTING EXTERIOR WALL <br />----------------------------- <br />SEAL <br />7870 REGISTERED <br />ARCHITECT <br />NIEL <br />STATE OF WASHINGTON <br />EXPIRES: APRIL 2021 <br />IDEAS ® CONSULT ® DESIGN ® PLAN <br />GAN <br />ARCHITECTS <br />POST OFFICE BOX NO. 4158 <br />EVERETT, WASHINGTON 98204 <br />TEL. NO. (425) 327-2690 <br />FAX NO. (425) 407-0714 <br />E-MAIL: dan@ganarchitects,com <br />The ideas, plans, and design concepts expressed <br />herein and graphically displayed arrangement of <br />their components represented by these drawings <br />have been developed for the exclusive use <br />of the specified project and are the sole <br />property of the Architects and Engineers. <br />Any conveyance or disclosure of the ideas, <br />plans, and design concepts or the use of any <br />graphically displayed arrangements of their <br />components shall be at the discretion of and <br />only through the expressed written consent <br />of the Architects and Engineers. <br />OWNER: <br />WASHINGTON MARINE <br />CLEANING, LLC <br />3430 16THI STREET <br />EVE:RETT, WA 98201 <br />CONTACT: GARY BALDWIN <br />T;BL: (42S) 311-8298 <br />PROJECT NAME: <br />TENANTIMPROVEMENT <br />SCOPE: <br />LABORATORY ALTERATION <br />5 MEZZANINE LEVEL OF <br />EXISTING MiARINE. CLEANING <br />SHOP <br />SHEET CONTENTS: <br />INTERIOR L V TG <br />AND SECTION <br />EXISTING CONDITION NOTE: <br />DRAWINGS ARE BASED ON VISUALLY <br />SEEN BUILDING ELEMENTS AND <br />MEASUREMENTS. HIDDEN COMPONENTS <br />SHOWN IN DRAWINGS ARE ASSUMED. <br />FURTHER INSPECTION IS NEEDED <br />TO CONFIRM PRESENCE OF SUCH <br />BUILDING ELEMENTS. <br />REVISIONS: <br />DATE: COMMENTS: <br />DRAWN BY: <br />DKG <br />CHECKED BY: <br />DATE: <br />9. 5.2 <br />SCALE: <br />AS NOTED <br />PROJECT NO. <br />20091-WAMAR <br />SHEET N0. A-2 <br />