118 SE EVERETT MALL WAY 2021 Plans 2022-11-30
>
Address Records
>
SE EVERETT MALL WAY
>
118
>
Plans
>
118 SE EVERETT MALL WAY 2021 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 2:29:48 PM
Creation date
2/24/2022 8:55:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
118
Permit
BW2104-002
Year
2021
Notes
CHANGE OF OCCUPACY FROM M TO B, NEW OFFICES, ADA RESTROOMS, FIRE DAMAGE REPAIR TO THE ATTIC, SOME STRUCTURAL WORK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A35 @24"oc (N) TRUSSES PER PLAN, <br />STRUCTURAL NOTES <br />MATCH (E) ROOF HEIGHT PITCH <br />THESE DRAWINGS REPRESENT STRUCTURAL REPAIRS FOR THE BUILDING To MITIGATE FIRE DAMAGE. REPLACEMENT AND <br />8d @6"oc <br />CONNECTIONS OF STRUCTURAL MEMBERS ARE SHOWN AS 'IN -KIND", NO UPGRADES ARE REQUIRED. <br />2x BLKG <br />DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE (113C). <br />BTWN TRUSSES <br />(N) SHEATHING <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO THE START OF CONSTRUCTION. <br />PER GEN NOTES <br />CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURAL COMPONENTS OF THE EXISTING STRUCTURE UNTIL <br />ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. <br />H2.5A EA TRUSS. _____z <br />H2.5A EA SIDE OF <br />MULTIPLE TRUSSES <br />(N) FASCIA <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR <br />DBL TOP P <br />ST2215 CTRD ON WHERE FIRE <br />':'I,-- <br />PROCEDURES REQUIRED TO PERFORM HIS WORK. <br />i <br />- REPLACE WHERE DAMAGE <br />EA PL SPLICE WHERE 11 <br />FIRE DAMAGE <br />(E) PILT TO BE REPLACED <br />DESIGN LOADS <br />(E) HDR (E) 2x EXTERIOR WALL <br />REROOF <br />SNOW 25 PSF <br />BRICK FASCIA <br />FIRELDAMAGE <br />ROOF DL 12 PSF <br />TO REMAIN <br />I <br />---------- - <br />lid <br />WIND DESIGN CRITERIA <br />NOTE: <br />II <br />WIND (ASCE 7-10) 110 MPH (3 sec gust), EXPOSURE "B", Iw=1,0, Kzt 1,0 <br />EXISTING ROOF SHEATHING CONSISTS OF PLY OVER Ix SKIP SHEATHING, <br />__ ____ <br />ETRUSS GIRDER <br />( ) <br />CONTRACTOR OPTIONS TO ADDRESS FINAL ROOF SHEATHING HEIGHT DIFFERENCE: <br />SEISMIC DESIGN CRITERIA <br />1. INCORPORATE INTO TRUSS HEEL HEIGHT. <br />2. ADD Ix SKIP SHEATHING BELOW THE NEW ROOF SHEATHING. <br />EARTHQUAKE (ASCE 7-10) SITE CLASS D <br />3. ADD TOP PLATE SHIM (CEILING HEIGHT WOULD STEP). <br />M <br />i <br />OCCUPANCY CATEGORY 11 (le = 1,0) <br />SEISMIC DESIGN CATEGORY D <br />Ss =1.375g, S11 = 0.488g <br />Sds=l.lg R=6.5 <br />LATERAL SYSTEM UNALTERED <br />7 <br />TYPICAL EAVE 1"=1' <br />09 <br />a <br />SOIL BEARING 1500 PSF (ASSUMED) <br />CARPENTRY <br />II <br />FRAMING - 2X, 4 HEM -FIR #2, Fb 850 PSIICI <br />UNDAMGED <br />GLU-LAM 24F-V4 <br />TRUSSES @249Poc <br />FRAMING HARDWARE DESIGNATIONS ARE SIMPSON STRONG -TIE, USE FULL AMOUNT OF FASTENERS SPECIFIED BY MFR. <br />2x BLKG BTWN <br />8d @i 2x6 OUTRIGGERS <br />OUTRIGGERS <br />7 <br />TO REMAIN, TYP <br />HARDWARE IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL BE Z-MAX OR HOT -DIPPED GALVANIZED. <br />LUS 1@24"oc <br />�—,t <br />FRAMING NAILING SHALL CONFORM TO TABLE 2304.10.1 OF THE 2018 IBC UNO. <br />HEADERS SHALL BEAR ON (2) 2X TRIM STUDS. <br />LTP4 @24 oc, TRUSS GIRDER PER PLAN <br />ROOF SHEATHING: 1/2" MIN PLYWOOD OR OSB, 24/0, EXT GRADE <br />NAIL ROOF SHEATHING WITH 8d COMMON (.131 >t 2-1 '2" DIA) @ 6" O.C. AT PANEL EDGES AND 12" O.C. AT INTERMEDIATE <br />A� <br />SHEATHE & NAIL <br />SUPPORTS. <br />PER GEN NOTES <br />WALL: 15/32" THICK PLYWOOD OR OSB, 32/16, OR 1/2" THICK, 24/0. SHEATHING MAY BE LAID UP HORIZONTALLY OR <br />x BLKG BTWN TRUSS WEB <br />8d @6"oc <br />VERTICALLY, UNSUPPORTED EDGES SHALL BE BLOCKED AND ALL EDGES SHALL BE NAILED WITH 8d @ 6"oc, NAIL WITH 8d @ <br />12"oc AT INTERMEDIATE SUPPORTS. NAIL SHEAR WALL SHEATHING TO ALL HOLDOWN STUDS USING EDGE NAIL SPACING WHEN <br />TRUSS <br />2x BLKG BTWN TRUSSES <br />i <br />HOLDOWN STUD DOES NOT OCCUR AT PANEL EDGES. <br />PER PLAN <br />W1 8d @i <br />�j <br />TRUSSES <br />SHEATHING <br />PER GEN NOTES <br />C-0 <br />TRUSS CALCULATIONS AND SHOP DRAWINGS SHALL BE PREPARED BY A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF <br />SLOPE SLOPE <br />WASHINGTON AND SUBMITTED TO THE LOCAL JURISDICTION FOR APPROVAL PRIOR TO CONSTRUCTION, <br />ROOF TRUSSES SHALL BE DESIGNED FOR: <br />TOP CHORD DL 8 PSF MIN <br />TOP CHORD ILL 25 PSF SNOW <br />BOTTOM CHORD DL 8 PSF MIN <br />Zz <br />PRE-ENG <br />TRUSSES SHALL BE ANCHORED WITH H2.5 CLIPS, <br />ROOF TRUSSES @24"oc <br />TO REPLACE DAMAGED TRUSSES <br />- ------------ - <br />HANGER <br />PER TRUSS MFR <br />STRUCTURAL GEIN'ERAL NOTES 11 <br />ROOF STEP <br />5 <br />—� __ __ <br />i <br />° ;I <br />° ' III <br />4/Sl <br />RUSS GIRDER <br />REPLACE DAMAGED —Fj <br />_ _ - �I—(N)' PRE 77EEG <br />DBIL TOP PLATE i <br />LLJ ROOF TRUSSES @24"'k, <br />i >I <br />—REPLACE <br />, <br />AS REQ'D 1 1 <br />TO DAMAGED TRUSSES <br />> <br />Lo UNDAMAGED HDR <br />TO REMAIN, TYP <br />- - - -- ------- --------- -------- <br />8d @6"oc CS16x8-O" <br />AT PEAK & TRUSS QUARTER POINTS <br />(E) SHEATHING CTR'D ON SHEATHING SPLICE. <br />_ <br />(E) Ix SKIP SHEA INJ1 <br />G <br />NOTES: <br />1. SEE ARCH FOR DIMENSIONS. <br />2x FLAT BLKG <br />BTWN TRUSSES <br />2. WALLS SHOWN ARE BELOW FRAMING. <br />LENGTH OF STRAP <br />3. NOTIFY ENGINEER IF EXISTING CONDITIONS <br />(E) PRE-ENG--____1 <br />DIFFER FROM CONDITIONS SHOWN ON PLAN. <br />i TRUSSES PER PLAN <br />TRUSSES <br />4- <br />2x LEDGER <br />SISTERED TO (E) TRUSS <br />TOP CHORD W1 16d @6"oc <br />IN <br />12 <br />9 <br />NEll /EXISTING <br />ROOF <br />COI <br />NECTION <br />1"=1—o <br />_ <br />6 <br />FLOORPLAN <br />Y8 <br />z1*1 <br />mm <br />07079' FOSSATTI PAWLAK <br />Km <br />ME S 7, R 'J ' I" 'U, -`-, Ak L `17- ihl G, � N E, E` R S <br />1735 Westlake Ave N, Ste 205 <br />Seattle, WA 98109 <br />Phone:206.456.3071 <br />Fax:206.456.3076 <br />www'fossatti.com <br />pl, p <br />17 <br />2_ <br />23024 <br />MIL <br />VAL <br />00 <br />0 <br />_j <br />00 <br />< <br />0-) <br />m <br />0 <br />CL <br />0 <br />u <br />V) <br />_j 00 LLJ <br />m <br />\�C- - DAIE <br />3/17/21 <br />21-040 <br />DATE <br />JOB # <br />KRS <br />FEE <br />DESIGN <br />CHECKED <br />BDS <br />AS NOTED <br />D R A VVT\1 <br />SCALE <br />N I <br />PLAIN c DETAILS, <br />GEI\IERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.