STR_UCTUR_A_LN,._0,TlElS_ <br />CODE <br />REINF0RCING STEEL <br />GALVANIZATION <br />ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, <br />REINFORCING STEEL SMALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL RE GRADE 60 (Fy <br />UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN COLT/ACT WITH TREATED WOOD SHALL BE GALVANIZED <br />SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS <br />= 60,000 PSI), UNLESS NOTED OTHERWISE, GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO RE WELDED <br />ACCORDING TO THE FOLLOWING TABLE: <br />WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. <br />SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL <br />PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE <br />GALVANIZATION i <br />UNTREATED <br />CCA-C <br />SBX <br />ACCI-C <br />ACQ-D <br />CBA-A <br />OTHER <br />ACZA <br />OTHER PT <br />WOOD <br />DESIGN LOADS <br />SUBMITTED. <br />WOOD <br />CA-S <br />BORATE <br />DEAD LOADS: <br />REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI <br />G90 <br />X <br />x <br />X <br />ROOF 15 PSF <br />318, LATEST EDITIONS. UNLESS OTHERWISE NOTED, ED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS <br />G185 <br />X I <br />X <br />X <br />X <br />X <br />X <br />FLOOR 15 PSF <br />SHALL BE PER SCHEDULE. <br />HIDG <br />X <br />X <br />X <br />X <br />X <br />X <br />LIVE LOADS: <br />MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO <br />STT300 <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />ROOF (SNOW LOAD) 25 PSF <br />APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE <br />RESIDENTIAL 40 PSF <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />(LIVE LOADS ARE REDUCED WHERE .PERMISSIBLE PER IBC SECTION 1607.11). <br />REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING <br />HDG = HOT DIP GALVANIZED <br />EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN <br />SST300 = TYPE 316L STAINLESS STEEL <br />EARTHQUAKE LOADS: <br />HARDENED CONCRETE SMALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL <br />RATED SHIEATHIING <br />ENGINEER. REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. <br />EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-16 SECTION 12.8. <br />RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE <br />MINIM49 LAPS AND EMBEDMENT <br />IN CONFORMANCE WITH IBC STANDARD 2303.1.5. <br />SITE CLASS (ASSUMED) D <br />SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1,182 <br />UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED <br />RPI nlAk <br />GLUE -LAMINATED TIMBER <br />ONE SECOND SPECTRAL RESPONSE ACCEL (Si) <br />0.420 <br />SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) <br />0.809 <br />ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) <br />0.526 <br />RISK CATEGORY <br />II <br />SEISMIC IMPORTANCE FACTOR (IE) <br />1.0 <br />SEISMIC DESIGN CATEGORY <br />D <br />BASIC SEISMIC FORCE -RESISTING -SYSTEM <br />PLYWOOD SHEAR WALLS <br />RESPONSE MODIFICATION FACTOR, (R) <br />6.5 <br />REDUNDANCY FACTOR (p) <br />1.0 <br />SEISMIC RESPONSE COEFFICIENT (CS) <br />0.125 <br />W = TOTAL SEISMIC ,DEAD LOAD AS DEFINED PER ASCE 7-16 SECTION 12.7.2. <br />BASE SHEAR (V), V = CSW = SDS <br />WIND LOADS. <br />BASIC WIND SPEED (3 SECOND GUST) <br />98 MPH <br />EXPOSURE <br />B <br />KZT <br />1.0 <br />SEE PLANS FOR ADDITIONAL DESIGN LOADS. <br />GLUE-LAIMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ,ANSI/AITC STANDARD <br />A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED <br />BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE <br />FOLLOWING MINIMUM STANDARDS: <br />STATEMENT OF SPECIAL INSPECTIONS <br />2, WALL SASE PLATE ON CONCRETE <br />CONCRETE COVER ON REINFORCING <br />SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A <br />WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS, <br />WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF <br />CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: <br />3" <br />BOLT PLATES OR SILLS TO CONCRETE STEM WALLS WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH <br />WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. <br />MINIMUM EMBEDMENT. PLACE AT 5'-C" OC MAXIMUM FOR SHEAR WALLS, AND AT 6-0" OC FOR BEARING WALLS <br />CONCRETE EXPOSED TO EARTH AND WEATHER: <br />AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF <br />STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. <br />#6 BARS AND LARGER <br />2" <br />END OF PLATES, TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL <br />#5 BARS AND SMALLER <br />,° <br />1 1/2 <br />PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4°' x 3"x 3" FLAT PLATE WASHERS. <br />FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY <br />SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER: <br />3. ROOF AND FLOOR FRAMING <br />SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. <br />SLABS, WALLS AND J06TS <br />3/4" <br />COLUMN TIES OR SPIRALS AND BEAM STIRRUPS <br />1 1/2" <br />PROVIDE 1 1/2" FULL DEPTH BLOCKING FOR .JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM <br />SPECIAL JNISPEOTI0N <br />EOIATE 8° 0" OC BLOCKINIC NOT REQ'D IF GWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF <br />it OPERATION 7'�� <br />SOILS <br />FOUNDATION BEARING CAPACITY VERIFICATION X <br />NOTE: <br />ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL <br />INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITHCOPIES OF ALL <br />RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT <br />TO THE ATTENTION OF THE DESIGN TEAM. <br />SOILS REPORT: REPORT NOT AVAILABLE AT TIME OF DESIGN <br />ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTIONS) <br />THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS <br />SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVALTWO WEEKS PRIOR TO PLACING <br />ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE <br />AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND <br />SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. <br />ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE <br />WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. <br />*PROVIDE fic SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS, 2500 PSI CONCRETE MEETS STRENGTH <br />REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. <br />CONCRETE GENERAL MOTES <br />ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO <br />POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED <br />BEYOND JOINT. <br />LUMBER <br />ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH W'WPA <br />GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: <br />SIZE CLASSIFICATION <br />i <br />a <br />,. t <br />11 JOISTS AND P <br />' <br />PLATES AND BLOCKING <br />y <br />6x AND LARGER BEAMS AND <br />STRINGERS <br />AND SMALLER BEAMS AND <br />x I <br />�� <br />REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. <br />CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8"OF SOIL SHALL BE PRESERVATiVE-TREATED BY <br />VACUUM -PRESSURE P,F r � STANDARD D , <br />NAIILS, BOLTS, AND METAL CONNECTORS ORWOOD <br />SHALLALL NAILS STANDARDS E FORTH BY THE NATIONAL DESIGN STANDARDS <br />WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING <br />ALL , LPLANS SHALL BE COMMOND OTHERWISE <br />14FFT al' EXCEF-D-TWF FOLLOWING MINIMUM GUIDELINES: <br />10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING <br />MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED <br />WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS <br />ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. <br />ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS <br />OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLIES FOR LAG BOLTS SHALL BE BORED FOR THE <br />SWANK AND THREADED PORTIONS PER NDS 12.1.4.2. <br />CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG <br />TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE MANUFACTURERSRECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED <br />BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, <br />SCREWS, OR BOLTS IN EACH MEMBER. <br />INSTALL SOUND BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND .THE SAME GRADE <br />(MINIMUM) AS MEMBERS CONNECTED. <br />UNO.INTER - <br />FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. <br />4. DIAPHRAGM NAILING <br />ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE <br />PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING <br />FRAMING WITH Bd NAILS AT 6" OC AT ALL PANEL EDGES .AND 12" OC AT ALL INTERMEDIATE SUPPORTS. <br />THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH <br />FACE OF SHEATHING. MAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. <br />5. ALLOWABLE STUD AND PLATE PENETRATIONS <br />CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN <br />EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING <br />PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN <br />NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. <br />6. GYPSUM WALLBOARD NAILING <br />ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS <br />OR NO. 13 GAUGE x 15/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED <br />OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE <br />WALL. <br />EXISTING BUILDING <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING <br />DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE <br />REDESIGN. <br />CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS <br />PENETRATED ED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. <br />GENERAL <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND <br />MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND <br />CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. <br />CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION <br />OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL <br />PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS <br />ONLY WILL NOT SATISFY THIS REQUI6TEMENT. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUB,JECTTO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL <br />ENGINEER. <br />W06/21 <br />ON <br />Ld <br />Q <br />L] Ln <br />0 <br />No <br />RM {I <br />r�IT <br />D <br />CHECK: <br />JGG <br />JOB N <br />21157.10 <br />