THE FOLLOWING NOTES APPLY EXCEPT WHERE SHOWN OTHERWISE <br />CODE INTERNATIONAL BUILDING CODE IBC (2015) <br />STRUCTURAL LOADS <br />FLOOR LIVE LOADS: <br />ROOF SNOW LOADS: <br />WIND LOADS: <br />EARTHQUAKE LOADS: <br />TYPICAL FLOOR LIVE LOAD = 50 PSF <br />GROUND SNOW LOAD, Pg = 15 PSF <br />ROOF SNOW LOAD, Pf = 25 PSF <br />SNOW EXPOSURE FACTOR, Ce =1.0 <br />SNOW LOAD IMPORTANCE FACTOR, Is =1.0 <br />THERMAL FACTOR, Ct =1.0 <br />BASIC WIND SPEED, Vult =115 MPH <br />RISK CATEGORY: II <br />WIND EXPOSURE: 'B' <br />Kzt =1.0 <br />SEISMIC RISK OCCUPANCY CATEGORY: II <br />SEISMIC IMPORTANCE FACTOR, le = 1.00 <br />MAPPED ACCELERATIONS, SS =1.3 S1 = 0.494 <br />SITE CLASS = C <br />DESIGN ACCELERATIONS, Sds = 0.96 Sd1= 0.48 <br />SEISMIC DESIGN CATEGORY: D <br />SHOP DRAWINGS <br />SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF <br />SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, BY INDICATING WHICH <br />MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED, AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICT <br />BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEE <br />THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. SUBMITTAL REVIEW IS FOR GENERAL CONFORMANCE ONLY; THIS REVIEW DOES NOT CHECK <br />DIMENSIONS OR QUANTITIES. <br />FOUNDATIONS <br />MAXIMUM SOIL PRESSURE 4000 PSF. EXTERIOR FOOTINGS SHALL BEAR V-6" (MINIMUM) BELOW FINISH GRADE. ALL FOOTINGS TO BEAR ON FIRM UNDISTURBED EARTH BELOW ORGANIC, <br />SURFACE SOILS AND SHALL BE LOWERED IF SUITABLE SOIL IS NOT FOUND AT ELEVATIONS SHOWN ON DRAWINGS. BACKFILL TO BE THOROUGHLY COMPACTED PER SPECIFICATIONS. <br />PROVIDE 2 #5 (MINIMUM) CONTINUOUS BOTTOM OF ALL WALLS AND FOOTINGS. FOR ADDITIONAL INFORMATION REFER TO SOILS REPORT NO. JN10176, BY GEOTECH CONSULTANTS INC., <br />DATED OCTOBER 4, 2016.. <br />CONCRETE <br />A. CONCRETE <br />ALL CAST -IN -PLACE CONCRETE SHALL BE WITH THE EXPOSURE CATEGORIES, WATER -CEMENT RATIOS, ENTRAINED AIR AND MINIMUM 28-DAY <br />COMPRESSIVE STRENGTHS AS INDICATED IN THE CONCRETE SCHEDULE ON THIS SHEET. <br />ELEMENTS EXPOSURE CATEGORY W/C AIR f'c <br />FOUNDATION FO SO CO 0 <br />SLAB ON GRADE EXPOSED TO WEATHER F2 SO C2 0.4 7 5000 <br />CONCRETE MIX DESIGNS FOR ALL CONCRETE ELEMENTS SHALL COMPLY WITH SECTION 19.3 OF AC1318-14 BASED ON THE EXPOSURE CATEGORIES LISTED IN THE ABOVE TABLE. NO <br />CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE. <br />B. REINFORCING <br />ALL REINFORCING BARS SHALL BE NEW BILLET STEEL ASTM A615, GRADE 60 CONFIRMING TO ACI 318 SECTION 20.2.2.5. <br />ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, SPACED IN FORMS, AND SECURED IN PLACE IN ACCORDANCE WITH THE PROCEDURES AND <br />REQUIREMENTS OUTLINED IN THE LATEST EDITION OF ACI 318, AND THE "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", ACI 315. <br />THE CONTRACTOR SHALL SUBMIT CHECKED SHOP DRAWINGS SHOWING REINFORCING DETAILS, INCLUDING STEEL SIZES, SPACING, PLACEMENT AND SUPPORT DETAILS AND DOWELS AT <br />EXPANSION JOINTS FOR REVIEW PRIOR TO FABRICATION. <br />ALL REINFORCING SPLICES SHALL CONFORM TO THE REQUIREMENTS OF LATEST EDITION OF ACI 318 AND THE SPLICE TABLE INCLUDED IN THE STRUCTURAL DOCUMENTS UNO. ALL WWR <br />SHALL BE LAPPED TWO (2) FULL MESH PANELS AND TIED SECURELY. <br />WHERE REQUIRED, DOWELS SHALL MATCH THE SIZE AND SPACING OF MAIN REINFORCING, UNO. <br />BAR SUPPORTS IN CONTACT WITH EXPOSED SURFACES SHALL BE PLASTIC TIPPED. <br />IN NON -PRESTRESSED CAST -IN -PLACE CONCRETE, THE SPECIFIED CONCRETE COVER FOR REINFORCEMENT SHALL NOT BE LESS THAN THE <br />FOLLOWING, UNLESS LARGER COVER IS NOTED ELSEWHERE. <br />• CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: <br />3 IN, <br />CONCRETE EXPOSED TO EARTH OR WEATHER: <br />95 BAR, W31, OR D31 WIRE AND SMALLER 1-1/2 IN. <br />CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />SLABS, WALLS, JOISTS: <br />#11 BAR AND SMALLER 3/4 IN. <br />C. CONSTRUCTION JOINTS <br />ALL CONSTRUCTION JOINTS SHALL BE ROUGH TO A MAGNITUDE OF %" AND SHALL BE WIRE BRUSHED, CLEANED AND MOISTENED IMMEDIATELY PRIOR TO PLACING NEW CONCRETE <br />F. GENERAL <br />THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL CONSTRUCTION JOINTS, CONTROL JOINTS, CURBS, SLAB DEPRESSIONS, SLEEVES, OPENINGS, ETC. <br />MINIMUM SLAB -ON -GRADE THICKNESSES SHALL BE 5" FOR SIDEWALKS, 8" FOR AUTOMOBILE TRAFFIC AREAS, AND 10" FOR TRUCK TRAFFIC AREAS, UNO. <br />ANCHORAGE TO HARDENED CONCRETE: <br />WHERE EXPANSION ANCHORS ARE SPECIFIED, USE "HILTI KWIK BOLT TZ" (REFERENCE ICC REPORT ESR-1917.) <br />WHERE SCREW ANCHORS ARE SPECIFIED, USE'SIMPSON TITEN HD" (REFERENCE ICC REPORT ESR-2713). <br />WHERE EPDXY ANCHORS ARE SPECIFIED, USE "HILTI HY-200" OR "SIMPSON SET-XP" (REF. ICC REPORT ESR-3187 AND ESR-2508). <br />FOR EPDXY ANCHORS, USE ASTM F1554 GRADE 36 THREADED ROD, UNLESS OTHERWISE NOTED. HOLES MUST BE CLEANED OF DUST AND DEBRIS AND BE FREE OF STANDING WATER <br />WHEN EPDXY IS INSTALLED. SPECIAL INSPECTION OF EPDXY ANCHORS IS REQUIRED. DO NOT CUT ANY REINFORCING BARS TO INSTALL ANCHORS. DEFECTIVE HOLES SHALL BE FILLED <br />SOLID WITH EPDXY. <br />FOR ANY SUBSTITUTIONS TO THE ABOVE, THE CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER MANUFACTURER'S LITERATURE DESCRIBING THE ANCHORS AND LISTING ICC <br />APPROVED ALLOWABLE SHEAR AND TENSION VALUES. <br />STRUCTURAL STEEL: <br />WIDE FLANGE SHAPES TO BE ASTM A992,FY=50KSI. <br />CHANNELS, ANGLES, AND PLATES TO BE ASTM A36, FY=36 KSI. <br />HSS RECTANGULAR AND SQUARE STRUCTURAL TUBE TO BE ASTM A500, GRADE B, FY=46 KSL <br />ALL STEEL EXCEPT STEEL EMBEDDED IN CONCRETE SHALL BE GIVEN ONE SHOP COAT OF APPROVED PAINT. <br />WELDS TO BE 3/16" MINIMUM CONTINUOUS FILLET, BY CERTIFIED WELDERS USING E70XX ELECTRODES. <br />ALL WELDING SHALL BE PERFORMED IN STRICT ADHERENCE TO A WRITTEN WELDING PROCEDURE SPECIFICATION (WPS) PER AWS D1.1. ALL WELDING PARAMETERS SHALL BE WITHIN THE <br />ELECTRODE MANUFACTURER'S RECOMMENDATIONS. WELDING PROCEDURES SHALL BE SUBMITTED TO THE OWNER'S TESTING AGENCY FOR REVIEW BEFORE STARTING FABRICATION OR <br />ERECTIONS. COPIES OF THE WPS SHALL BE ON SITE AND AVAILABLE TO ALL WELDERS AND THE SPECIAL INSPECTOR. <br />STEEL TO STEEL BOLTED CONNECTIONS ARE SHOWN TO BE BEARING -TYPE CONNECTIONS USING A325 BOLTS WITH THREADS INCLUDED IN THE SHEAR PLANE. HOLE SIZE SHALL BE IN <br />ACCORDANCE WITH AISC SPECIFICATION FOR BEARING CONNECTION AND BOLTS SHALL BE TIGHTENED TO SNUG -TIGHT CONDITION. <br />WHERE BOLTS ARE NOTED A325SC, CONNECTIONS SHALL BE FRICTION -TYPE CONNECTIONS WITH BOLTS TENSIONED AND USING APPROPRIATE HARDENED STEEL WASHERS AS REQUIRED <br />BY RISC STANDARDS. <br />ANCHOR BOLTS EMBEDDED IN CONCRETE OR MASONRY ARE ASTM F1554 GRADE 36, UNLESS OTHERWISE NOTED. USE HEADED ANCHOR BOLTS, NOT "J" BOLTS. DO NOT ENLARGE HOLES <br />IN BASE PLATE BY BURNING. BENDING OF ANCHOR BOLTS IS PERMITTED ONLY WITH THE PRIOR APPROVAL FROM THE ENGINEER. <br />S WHERE NOT SPECIFICALLY SHOWN BY DETAIL, CONNECTIONS SHALL BE BOLTED FRAME BEAM CONNECTIONS PER AISC STANDARDS. DURING ERECTION, STRUCTURAL STEEL SHALL BE <br />R, SECURED FROM COLLAPSING WITH TEMPORARY BRACING. <br />SUBMIT SHOP DRAWINGS PREPARED BY AN EXPERIENCED DETAILER FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWINGS TO BE COMPLETE, SHOWING ALL WELDS AND MATERIAL <br />GRADES. PROVIDE A PLAN LOCATION OR DETAIL REFERENCE FOR EACH SHOP DRAWING. FOR MINOR STEEL -TO -STEEL CONNECTIONS OF 12" AND SMALLER STEEL MEMBERS: IF AN <br />EXPLICIT CONNECTION IS NOT SHOWN ON THE STRUCTURAL DRAWINGS, DETAILER IS TO PROPOSE A CONNECTION SIMILAR TO THE CONNECTIONS ON THE DRAWINGS OR PER AISC <br />STANDARD CONNECTIONS. ON THE SHOP DRAWING, CLOUD THE CONNECTION AND STATE "VERIFY." SHOP DRAWINGS NOT MEETING THESE CONDITIONS WILL BE REJECTED. REVIEW OF <br />SHOP DRAWINGS BY THE ENGINEER IS FOR DESIGN INTENT ONLY, AND DOES NOT INCLUDE VERIFICATION OF DIMENSIONS AND QUANTITIES. VERIFICATION OF DIMENSIONS AND <br />QUANTITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />STEEL FABRICATORS AND DETAILERS: BASE BID TO INCLUDE STEEL DETAILER AND FABRICATOR TIME AND COSTS FOR ROUTINE CONSTRUCTION QUESTIONS. ROUTINE CONSTRUCTION <br />QUESTIONS INCLUDE DIMENSIONAL QUESTIONS AND MINOR FRAMING QUESTIONS. ROUTINE CONSTRUCTION QUESTIONS ARE PART OF THE NORMAL CONSTRUCTION PROCESS, AND ARE <br />TO BE INCLUDED IN THE BASE BID. <br />SCOPE OF STRUCTURAL ENGINEERING SERVICES: <br />THE STRUCTURAL ENGINEER HAS PERFORMED THE STRUCTURAL DESIGN AND PREPARED THE STRUCTURAL WORKING DRAWINGS FOR THIS PROJECT. THE CONSTRUCTION MUST BE <br />PERFORMED IN STRICT ACCORDANCE WITH THE STRUCTURAL DRAWINGS. ANY DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />ERRORS AND/OR OMISSIONS FOUND ON THE STRUCTURAL DRAWINGS MUST BE BROUGHT TO THE STRUCTURAL ENGINEER'S ATTENTION IMMEDIATELY. <br />PRIMARY STRUCTURAL ELEMENTS ARE DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL <br />DRAWINGS. ANY DISCREPANCIES, CONTRADICTIONS, OR OMISSIONS SHALL BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK OR FABRICATION OF <br />THE ITEM(S) IN QUESTION. <br />THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM, EXCEPT FOR ANY COMPONENTS NOTED ABOVE. RESPONSIBILITY FOR ANY <br />SECONDARY STRUCTURAL AND NON-STRUCTURAL SYSTEMS NOT SHOWN ON THE STRUCTURAL PLANS RESTS WITH SOMEONE OTHER THAN THE STRUCTURAL ENGINEER. <br />THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN ITS COMPLETED FORM. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACING TO STABILIZE THE <br />BUILDING DURING CONSTRUCTION. <br />THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR <br />SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE CONSTRUCTION WORK, NOR WILL HE BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE <br />CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />FIELD MEASUREMENTS AND THE VERIFICATION OF FIELD DIMENSIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY. THE CONTRACTOR MUST CHECK ALL (ASSUMED) <br />EXISTING CONDITIONS SHOWN ON THESE DRAWINGS FOR ACCURACY AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES. <br />OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR THE INADVERTENT MISLABELING OF DETAILS OF WORK WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE <br />DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INADVERTENT MISLABELED <br />DETAILS OF THE WORK BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED iN THE DRAWINGS AND SPECIFICATIONS. <br />PLACE ALL SLABS -ON -GRADE IN STRIP POURS OF 30 FEET MAXIMUM WIDTH WITH A MINIMUM OF 24 HOURS BETWEEN ADJACENT POURS, STRIP POURED SLABS SHALL HAVE SAW CUT <br />CONTROL JOINTS SPACED AT 36 TIMES THE SLAB THICKNESS (15'-0" MAXIMUM) ON CENTER. SAW CUTTING SHOULD BE PERFORMED BEFORE THE CONCRETE STARTS TO COOL AFTER PEAK <br />HEAT OF CEMENT HYDRATION, AND AS SOON AS THE CONCRETE HAS HARDENED ENOUGH TO SUPPORT EQUIPMENT WITHOUT DAMAGE AND NOT RAVEL THE CONCRETE DURING CUTTING, <br />SAW CUTTING SHALL BE DONE WITHIN 12 HOURS OF CONCRETE PLACEMENT. <br />D. CURING AND SEALING <br />PROVIDE SPECIFIED CURING COMPOUND AND SEALER FOR THE TOP SURFACE OF ALL SLAB WORK, UNLESS NOTED OTHERWISE. VERIFY COMPATIBILITY OF SPECIFIED SEALERS AND/OR <br />HARDENERS WITH ARCHITECTURAL TOPPINGS AND FINISHES. <br />E. TOLERANCES <br />ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 117, LATEST EDITION, "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS AND <br />COMMENTARY", EXCEPT AS MODIFIED BY THESE DOCUMENTS. <br />SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR TYPE AND LOCATION OF ALL FLOOR FINISHES, FLOOR DEPRESSIONS, AND NON-STRUCTURAL CURBS. <br />SLABS SHALL MEET THE FLOOR FLATNESS (FF) AND FLOOR LEVELNESS (FL) TOLERANCES INDICATED IN SPECIFICATIONS. FINISHED FLOOR SLABS THAT DO NOT MEET THE SPECIFIED <br />SURFACE TOLERANCES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. CONTRACTOR TO SUBMIT PROPOSED REPAIR PROCEDURES TO THE ARCHITECT/STRUCTURAL ENGINEER <br />FOR REVIEW AND APPROVAL PRIOR EXECUTION OF REPAIR WORK. <br />KEY PLAN <br />SCALE: NTS <br />REVISION I DATE <br />Permit#: B2009-011 <br />Site Address: 1407 80TH ST SW <br />Owner: ACHILLES USA INC <br />Tenant: ACHILLES USA INC <br />App. Date: 9/9/2020 <br />Proposed Use: COMMERCIAL <br />Description: REMOVE 6 METAL SILOS AND INSTALL 1 <br />NEW SILO USING EXTG FNDTN <br />Reviewed By:)VvDate: <br />Office Set Job Site t Fire/Planning Set <br />Tbt <br />2Pg <br />EVERETT FIRE DPSM <br />THESE DOCUMENTS HAVE NOT BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PUBLIC WORKS, MECHANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS. <br />I T Y OF LEVEff l,. _ <br />RVIE-WED FOR PERMIT <br />'fir I `j - <br />U <br />Z <br />u <br />rV <br />w <br />O <br />E <br />V <br />W <br />0 <br />Z <br />:D <br />U <br />LL1 <br />C� <br />z <br />0 N <br />Z , <br />C <br />j�� <br />W <br />� <br />QQL <br />N <br />� <br />O <br />~�N <br />XW`p <br />cn <br />U <br />Z� <br />OQ� <br />v� <br />0. <br />N W .. <br />Ncn(L <br />�� <br />cn <br />Z <br />QN00 <br />F— <br />3 <br />M <br />0. <br />.� <br />W <br />Noon" <br />Z <br />coo <br />O <br />F-= <br />v <br />0 <br />�- <br />Q <br />F <br />LE] <br />G1G <br />cn <br />t.✓V <br />cn � <br />0 <br />W rZ <br />z —, <br />O <br />W C�.. <br />W tZ L <br />cz <br />T <br />0 <br />E <br />JOB No. 20084 a <br />DWN BY: MB In <br />00 <br />CHKD BY MDS <br />0 <br />DATE 8/4/2020 ` <br />0 <br />SHEET No. <br />3 <br />co <br />e 0 <br />co i <br />co <br />0 <br />0 <br />N <br />