166 LF 8" D.I. <br />CONNECT TO EXISTING. <br />COORDINATE WITH SURVEYOR <br />FOR CONNECTION. <br />4 LF 6" D.I. — <br />47 LF 8 D.I.— <br />�D <br />0 <br />62 LF 8" D.I. <br />EXISTING FIRE AND DOMESTIC — J-- — i <br />WATER SERVICES TO REMAIN. <br />EXISTING BACKFLOW DEVICES TO REMAIN I <br />I <br />i— --- <br />i <br />I <br />„® <br />— — _S,p <br />AP <br />1i <br />lam _N MROadaO-- <br />-SEVER)", <br />przo <br />TRIAL <br />� _ I �sts tx �a7 Ada PS A'��a rOR— <br />LEGEND <br />DOMESTIC WATER PIPE <br />1 WATER TEE W/ THRUST BLOCKING <br />IAE� 90' WATER BEND W/ THRUST BLOCKING <br />45° WATER BEND Wj THRUST BLOCKING <br />GATE VALVE <br />FIRE HYDRANT <br />NOTE — 91500 ixcP'k <br />ALL EXISTING WATER LINES SHALL BE SURVEYED <br />AND CHECKED FOR CONFORMANCE WITH CITY <br />RECORDS. EXISTING WATERLINE LOCATION SHALL <br />BE DOCUMENTED IN FINAL ASBUILTS <br />a <br />CITY OF EVERETT WATER I E` <br />WATERL <br />CONNECT TO EXISTING WATER MAIN <br />1-8" VERTICAL BEND (MJ) <br />SEE COE WATER NOTES (B) BELOW. <br />TEE (FLxMJ); 1-6" GATE VALVE (FLxMJ) <br />O1-8"x6" <br />THRUST RESTRAINT PER COE STANDARDS <br />O1—FIRE <br />HYDRANT ASSEMBLY PER CITY <br />OF EVERETT STD, DETAIL 507 <br />1-8" 45° BEND (MJ) <br />THRUST RESTRAINT PER COE STANDARDS <br />O1-8" <br />45° BEND (MJ) <br />THRUST RESTRAINT PER COE STANDARDS <br />O1-8"x6" <br />TEE (FLxMJ); 1-6" GATE VALVE (FLxMJ) <br />THRUST RESTRAINT PER COE STANDARDS <br />O1—FIRE <br />HYDRANT ASSEMBLY PER CITY <br />OF EVERETT STD. DETAIL 507 <br />O1-8" <br />45° BEND (MJ) <br />THRUST RESTRAINT PER COE STANDARDS <br />O1-8" <br />45° BEND (MJ) <br />THRUST RESTRAINT PER COE STANDARDS <br />10 <br />CONNECT TO EXISTING WATER MAIN <br />1-8" VERTICAL BEND (MJ) <br />NOTE: USE MEGA LUG RESTRAINTS OR EQUAL <br />ON ALL MECHANICAL JOINTS LARGER THAN 2" <br />THRUST RESTRAIN LENGTH SHALL BE PER TABLE 5A. <br />Fitting <br />Diameter <br />Leng IS to be Ro°+Ls.'ained irtEath <br />Erection <br />i [ 1 4" bend <br />5, b' <br />I0, I <br />45" bien l <br />15' 20. <br />25 <br />90" btynel"' <br />45" <br />ta(t' <br />Tees (wheve all lcg"4 salt be <br />201 25' <br />; <br />Dead Ends and Ecc. (where <br />nnly one bqtnoh is instaned- <br />11 60' 80 <br />I w <br />1 Sttt1 boTi€t;t, tc g btri d,t connecong to C'a:at Iron pipe, wxt clo a€d cads <br />a lust caste thrust blocks ill eakfiteraaa to this toble , <br />A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED EXCEPT BY MEANS OF AN APPROVED BACKFLOW PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, <br />TESTING, DISINFECTION, AND RECEIPT OF SATISFACTORY BACTERIOLOGICAL TEST RESULTS. <br />B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE BY THE CITY UTILITIES DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE CITY UTILITIES DEPARTMENT <br />SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION. THE CITY UTILITIES DEPARTMENT SHALL THEREAFTER DETERMINE THE DATE AND TIME <br />AT WHICH THE CONNECTION SHALL BE MADE. <br />C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT STANDARDS, DEC 2016. <br />D. A PRE —CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF CONSTRUCTION. THE CITY OF EVERETT ENGINEERING DEPARTMENT <br />CONSTRUCTION DIVISION MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SHALL NOTIFY THE CITY UTILITIES DEPARTMENT OF A PERSON WHO CAN BE CONTACTED REGARDING <br />PROBLEMS DURING CONSTRUCTION ON A 24 HOUR BASIS. <br />F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL SEPARATION BETWEEN POTABLE AND NON —POTABLE CONVEYANCE SYSTEMS. <br />G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY CITY UTILITIES DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL BE ACCESSIBLE AT <br />ALL TIMES. <br />WATER NOTES (NAVIX) <br />1. ALL CONSTRUCTION/INSTALLATION OF WATER MAINS SHALL BE DONE IN A SAFE, NEAT AND WORKMANLIKE MANNER, AND UNDER SUPERVISION BY UTILITY <br />PROVIDER FORCES AT ALL TIMES. ALL SAFETY REQUIREMENTS FROM OSHA AND OTHER STATE REGULATING AGENCIES MUST BE MET. <br />2. WATER MAIN PIPE MATERIAL SHALL BE CLASS 52 DUCTILE IRON. 6-INCH FIRE HYDRANT LATERALS TO BE CLASS 52 DUCTILE IRON PIPE. <br />3. AN 18-INCH MINIMUM SEPARATION IS REQUIRED ON SERVICE TAPS ON A MAIN LINE. <br />4. SADDLES SHALL BE USED ON ALL TAPS IN ANY PUBLIC MAIN. <br />5. ALL ELBOWS/BENDS ON WATER MAINS SHALL HAVE THRUST BLOCKS AND USE RESTRAINT GLANDS (MEGALUG OR EQUAL). <br />6. ALL NEW PIPES MUST BE PROPERLY FLUSHED, PRESSURE TESTED, CHLORINATED AND INSPECTED BY UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH <br />JURISDICTION, CONTRACTOR MUST COORDINATE FLUSHING, TESTING AND DISINFECTING WITH COE. <br />7. ALL BACKFLOW PREVENTION DEVICES (DOUBLE CHECK BACKFLOW PREVENTORS, REDUCED PRESSURE BACKFLOW PREVENTORS, PRESSURE AND ATMOSPHERIC <br />VACUUM BREAKERS, ETC.) MUST BE APPROVED BY THE UTILITY PROVIDER AND GOVERNMENTAL AGENCIES WITH JURISDICTION. <br />8. ALL NEW CONNECTIONS TO EXISTING WATER MAINS REQUIRE ISSUANCE OF A PUBLIC WORKS PERMIT AND WILL BE CONDUCTED BY THE COE, <br />9. BACKFLOW PREVENTION DEVICES SHALL BE CONSTRUCTED OF CORROSION RESISTANT MATERIALS. <br />10. AS PART OF THE BASE BID, THE CONTRACTOR SHALL INCLUDE VERTICAL BENDS AND THRUST BLOCKS, AS NECESSARY, TO ACCOMMODATE PROPOSED UTILITY <br />CROSSINGS. <br />11, ALL GATE VALVES THAT ARE LOCATED IN LANDSCAPE AREAS SHALL HAVE CONCRETE COLLAR. <br />12. INSTALL WATERLINES 12" AND SMALLER A MINIMUM OF 36" BENEATH FINISHED GRADE PER CITY OF EVERETT SPECIFICATIONS, <br />13. REPLACE ALL PAVEMENT, LANDSCAPING AND FACILITIES DAMAGED DURING THE WATERLINE INSTALLATION TO PRE —CONSTRUCTION CONDITION OR BETTER. <br />GENERAL UTILITY NOTES (NAVIX) <br />1. ALL IMPROVEMENTS SHALL MEET LOCAL, STATE DOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (A.P.W.A.) STANDARD SPECIFICATIONS. <br />2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOOUS,OT REPRESENT A DETAILED FIELD <br />SURVEY, THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON A SURVEY PREPARED INC DATED <br />THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE <br />DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF <br />CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS <br />OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. <br />3. CAUTION — NOTICE TO CONTRACTOR <br />THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON <br />RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD, THE INFORMATION IS NOT TO BE RELIED ON AS BEING <br />EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT <br />FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS <br />WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. <br />4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND DIMENSIONS OF SLOPED PAVING, EXIT PORCHES, SIDEWALKS, RAMPS AND <br />TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS, <br />5. ALL FILL MATERIAL SHALL BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES. <br />6. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES INSPECTORS 72 HOURS BEFORE CONNECTING TO ANY EXISTING LINE. <br />7. MINIMUM WATER AND SANITARY SEWER TRENCH WIDTH SHALL BE 2 FEET. <br />8, ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF <br />PIPE), <br />9. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATERLINES, SANITARY LINES, STORM LINES AND GAS LINE (EXISTING AND PROPOSED), THE SANITARY LINE <br />SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATERLINE SHALL BE MECHANICAL JOINTS <br />WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" CLEARANCE, MEETING REQUIREMENTS OF ANSI A21.10 AND ANSI 21.11 <br />(AWWA C-151) (CLASS 52). <br />10. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING. <br />11, CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH THE SPECIFICATIONS OF THE LOCAL AUTHORITIES WITH REGARD TO MATERIALS AND INSTALLATION OF THE <br />WATER AND SEWER LINES. <br />12. ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO <br />ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION OF SERVICE. <br />13. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. <br />N"'I'llod'ook" <br />i"'OS MCI 11 f' <br />�� <br />S soy <br />pF WASg <br />46437 <br />GI STE�� <br />�SroNat, E�� <br />1112012017 <br />REVISIONS <br />lk4p <br />REV ISSUED FOR: DATE <br />1 CITY PERMMT 09.13.17 <br />SHEET NUMBER <br />rem <br />