Laserfiche WebLink
�I o <br />1 INCH MIN �— <br />TYPICAL AT <br />TOP 4 BTM <br />2X HEM/FIR 02 <br />LEDGER SEAM <br />PT DECK JST OR RAFTER <br />W/ JST HGRS PER PLAN <br />MIN ISga. U-TYPE JST HGR <br />INSTALL PER MFR'5 SPEC5 <br />L 1/2' x 4 1/2' MIN 6052.5 LAG SCREWS <br />W/ FLAT WASHERS 9 16' O.G. <br />ALTERNATE HIGH 4 LOW LOCATION <br />THRU RIM JOIST OR STUDS <br />LEDr-zEF---, IDETAIL <br />NTS (A5 APPLICABLE) <br />DOWNSPOUT ( FLEXIBLE OR <br />RIGID PIPE) CONNECT TO <br />BLD'G. ROOF DRAIN — <br />SLOPE FINISH GRADE <br />AWAY FROM FOUNDATION <br />29, MIN. (1/4' - 12') <br />4' RIGID, NON -PERFORATED <br />DRAIN PIPE - DO NOT CONNECT <br />WITH FTG. DRAIN LEADER — <br />SILT BARRIER ( BLD-G. <br />PAPER, FILTER FABRIC OR <br />POLYETHELENE FILM) <br />WASHED ROCK (MIN. 3/4' DIM.) <br />W/ MIN. 12' COVER ,@ TOP .I <br />51DES AND BTM. - <br />MIN. 4' RIGID, PERFORATED, <br />CORRIGATED DRAIN PIPE <br />i <br />2 X RAFTERS PER PLAN <br />3-TAB 2350 COMP ROOF OVER <br />3011 FELT - INSTALL PER MFR'S <br />1/2' CDX ROOF SHEATHING <br />OR EQUAL W/ ad NAILS e (o' O.G. <br />AT ALL PANEL EDGES 4 12' O.G. <br />AT INTERMEDIATE SUPPORTS <br />ad m &' O.C. ONTO BLKG <br />2x SOLID BLOCKING — <br />511-11=50N Hi SEISMIC — <br />TIES 15) EACH RAFTERS <br />2G GA. MTL -� <br />GUTTER <br />I X FACIA <br />USE ROCKWOOL OR OTHER <br />NONCOMBUSTIBLE MATERIAL <br />AS FIRESTOP (FIBERGLASS 15 <br />UNACCEPTABLE AS FIRESTOP) <br />PROVIDE SHEAR WALL <br />PANELS AS NOTED ON <br />PLANS AND SHEARWALL <br />SCHEDULE <br />SIDING A5 PER ELEVATIONS <br />MOISTURE BARRIER <br />PROVIDE 3' X 3' SQ. X 3/1&' <br />THICK ANCHOR BOLT WASHERS <br />5/V X lo' ANCHOR BOLTS <br />PER SHEAR SCHEDULE <br />PROVIDE A.B. NOT LESS THAN l <br />BOLT DIAMETERS 4 NOT MORE <br />THAN 12' FROM ENDS OF EA. <br />FDN. SILL PLATE —\ <br />2 X 6 FDN GRADE <br />51LL PLATE <br />�Q I Iz GRADE <br />� =III=III= <br />NOTE. OA II-: <br />CONFIRM WITH BLD'G. I -I <br />OFFICIAL ANY SPECIAL <br />REQUIREMENTS FOR <br />WATER RUNOFF AND TYP. DRAIN <br />STORM SEWER NOOK -UP PIPE - SEE — <br />• a �� <br />DRAIN DET. <br />12" <br />12 <br />SEE <br />ELEV <br />— AIR TIGHT SPRAY FOAM INSULATION <br />GREATER OR EQUAL TO ADV R-38 INSUL <br />1/2' GYP BD <br />2-2X6 TOP PLATES - LAP 6PLICE5 48' <br />RIGID INSULATION. <br />4X8 HEADER (UNLESS OTHERWISE NOTED) <br />2XG STUDS m 16'o.c. <br />R-21 INSULATION <br />VAPOR RETARDER <br />1/2' GYP BD <br />4' GONG. SLAB W/ 6X6 W2.1 X W2.1 WWM <br />OVER 2' SAND OVER 6 MIL VAPOR BARRIER <br />OVER 4' COMP FREE DRAINING ROCK <br />SLOPE a Ye' PER FT TOWARDS GARAGE DR <br />CONT CONC FTG - PROVIDE 04 REBAR <br />s 10'o.c. HORIZ. 4 IS' O.G. VERT. IN <br />FDN, WALL, TIE VERT TO FTG AS SHOWN <br />ALTERNATE HOOK 4 (2) 1*4 IN FOOTING <br />REVIEWED FOR PERMIT <br />