My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4330 HOYT AVE 2022-03-01
>
Address Records
>
HOYT AVE
>
4330
>
4330 HOYT AVE 2022-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2022 1:26:38 PM
Creation date
3/1/2022 1:20:55 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4330
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C4M civil&structural <br /> engineering planning <br /> ENGINEERINGi i & l i <br /> JUN °3 r 2020 <br /> June 22,2020 CITY OF EVERETT <br /> Permit Services <br /> Drew Martin,P.E,S.E <br /> City of Everett <br /> 3200 Cedar Street, <br /> 2nd Floor, <br /> Everett,WA 98201 <br /> RE: Permit Number: B1908-042 <br /> Project Name: Everett Duplex Foundation Repair <br /> Project Address: 4328 Hoyt Ave, Everett,WA 98203 <br /> CG Project Number: 20188 <br /> Dear Mr. Martin, <br /> Itemized below is our response to the review comments dated April 27th 2020 for the above referenced <br /> project. Our response appears in bold. <br /> 1. The scope of the project is not clear. The submitted drawings appear to be combination of <br /> marked-up issued drawings from the original submittal and supplemental structural foundation <br /> drawings. The mark-ups only show the building addition,with the garages marked as"deleted", <br /> while the structural drawings show both. Please clarify the project scope. See IBC Section 107.2.1. <br /> The project scope is per the originally-approved plans with the following exceptions: <br /> - The two new garages have been deleted from the project by the Owner. <br /> - The foundation system of the addition has been changed to a pile-supported foundation <br /> with grade beams, because unsuitable bearing soils were encountered during <br /> construction. <br /> 2. Structural and geotechnical special inspections are required for this project. A table should be <br /> provided listing the type and extent(e.g., periodic,continuous, etc.)of each inspections. See IBC <br /> Tables 1705.3, 1705.6 and 1705.7. <br /> Structural observation and geotechnical special inspection requirements have been added to <br /> S1.1. Note that we are not requiring structural special inspections. <br /> 3. Structural observation should be performed for this project. A requirement should be included <br /> in the drawings. See IBC Section 1704.6.1(5). <br /> Structural observation of the pin pile installation has been added to the structural notes on <br /> 51.1. <br /> 250 4th Avenue South,Suite 200 <br /> Edmonds,WA 98020 <br /> ph.425.778.8500 I f.425.778.5536 <br /> www.cgengineering.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.