Laserfiche WebLink
, ^ <br /> J. This comment has not been addressed.The project includes steel construction per Detail l4/S' <br /> 2 (previously Detail 11/S'1\that requires special inspection, as stated in the original review <br /> comment. It is presumed that the fabrication will be performed on the premises of a <br /> fabricator's shop, Special inspections are required to be performed by the fabricator unless <br /> they are registered and approved to perform work without special inspections. The Structural <br /> Notes on Sheet S-1 should be revised tn list work being per-fonnedbxapprovedfabhcatoo- <br /> VVOrknotbeino performed by approved fabricators should be added U»the list of special <br /> inspections.See |B[Sections 17O4.J.5, 1704.Z.S.1, and Section 17O4.S Items 1 and 2. <br /> RES9O0ASE�1The Structural Notes mnShk`S'1 and S-2ne��sed and to list mmork being performed by <br /> ppprmwed fabricators mr added hz the Rm�ef special inspection. <br /> 3.Th|s comment has not been completely addressed. An illegible note has been added to the <br /> "Prefabricated Plywood Web Joists" portion of the Structural Notes on Sheet S'1.The structural <br /> drawings include work that has been deferred by the structural engineer. A statement nf <br /> deferred submittals should be added to the Structural Notes on Sheet S-1 listing work <br /> designated as deferred submittals. The note shall include a statement requiring the eogimccr <br /> Qf-nccncdU}reviewthedefernedsubnnitta|yandvedfwconforrnancewiththeconst[uction <br /> documents.See IBC Sections lO7.Z.1' 1073.4, 1O7.3.4.1, and 1O7'4. <br /> RESPONSE:"Prefabricated Plywood Web Joists' note added Structural Notes°K"onthe Sht`S-1 <br /> Foundation System: <br /> 7.The following comments regarding the foundation design have not been completely addressed: <br /> a.The foundation elevations should bespecified. Sheet A4.0 appears to have atop'of-dab <br /> elevation added for the Basement floor, but no other elevations appear to be specified. See <br /> IBC Section 107.2-I <br /> RESPONSE: Foundation elevations added <br />