My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2401 TAYLOR DR Geotech Report 2022-10-25
>
Address Records
>
TAYLOR DR
>
2401
>
Geotech Report
>
2401 TAYLOR DR Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:01:33 PM
Creation date
3/2/2022 8:55:30 AM
Metadata
Fields
Template:
Address Document
Street Name
TAYLOR DR
Street Number
2401
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2401 Taylor Drive Geotechnical Engineering Study <br /> Everett, Washington <br /> The area bounded by lines extending downward at 1H:1V (Horizontal:Vertical) from any footing <br /> must not intersect another footing or intersect a filled area that has not been compacted to at <br /> least 95 percent of ASTM:D 1557. In addition, a 1. 5H:1V line extending down from any footing <br /> must not daylight because sloughing or raveling may eventually undermine the footing. Thus, <br /> footings should not be placed near the edges of steps or cuts in the bearing soils. <br /> All footing areas should be observed by SGP prior to placing concrete to verify that the exposed <br /> soils can support the design foundation bearing capacity and that construction conforms with <br /> the recommendations in this report. Foundation bearing verification may also be required by the <br /> governing municipality. <br /> Structural Fill <br /> Structural fill may be necessary to establish desired grades. All references to structural fill in this <br /> report refer to subgrade preparation, fill type, placement, and compaction of materials as <br /> discussed in this section. If a percentage of compaction is specified under another section of this <br /> report,the value given in that section should be used. <br /> After stripping, planned excavation, and any required over-excavation have been performed to <br /> the satisfaction of the geotechnical engineer/engineering geologist, the upper 12 inches of <br /> exposed ground should be recompacted to a firm and unyielding condition. If the subgrade <br /> contains too much moisture,adequate recompaction may be difficult or impossible to obtain and <br /> should probably not be attempted. In lieu of recompaction, the area to receive fill should be <br /> blanketed with washed rock or quarry spalls to act as a capillary break between the new fill and <br /> the wet subgrade. Where the exposed ground remains soft and further over-excavation is <br /> impractical, placement of an engineering stabilization fabric may be necessary to prevent <br /> contamination of the free-draining layer by silt migration from below. <br /> After recompaction of the exposed ground is approved, or a free-draining rock course is laid, <br /> structural fill may be placed to attain desired grades. Structural fill is defined as crushed rock, <br /> acceptable to the geotechnical engineer, placed in maximum 8-inch loose lifts with each lift being <br /> compacted to 95 percent of ASTM:D-1557. In the case of roadway and utility trench filling, the <br /> backfill should be placed and compacted in accordance with local codes and standards. The top <br /> of the compacted fill should extend horizontally outward a minimum distance of 3 feet beyond <br /> the location of the perimeter footings or roadway edges before sloping down at a maximum angle <br /> of 2H:1V. <br /> The contractor should note that any proposed fill soils must be evaluated by SGP prior to their <br /> use in fills. This would require that we have a sample of the material at least 72 hours in advance <br /> to perform a Proctor test and determine its field compaction standard. Soils in which the amount <br /> of fine-grained material (smaller than the No. 200 sieve) is greater than approximately 5 percent <br /> (measured on the minus No. 4 sieve size) should be considered moisture-sensitive. Use of <br /> November 6,2019 SONDERGARRD GEOSCIENCES, PLLC <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.