8615 7TH AVE SE 2022-03-02
>
Address Records
>
7TH AVE SE
>
8615
>
8615 7TH AVE SE 2022-03-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 10:06:48 AM
Creation date
3/2/2022 10:03:35 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8615
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
199
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Prescriptive Path, pg. 2 ENV-PRESCRIPTIVE <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: St Mary Magdalen Gym Date 07/01/2016 <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then the project must comply <br /> via Component Performance and provide ENV-UA and ENV-SHGC forms. <br /> BuildingComponent R-Value Method for U-Factor/F-Factor Method for <br /> P Prescriptive Compliance Prescriptive Compliance <br /> Perim. Ins. Full Slab CI <br /> Provide plan/detail#of assembly and description R-Value R-Value F-Factor F-Factor Source10 <br /> cu <br /> 6) m <br /> ar <br /> m .0 <br /> a`1 c <br /> O 0 A1.1,A5.1,A5.2 10.0 <br /> Ins. I Assembly <br /> Provide ID from door schedule and description R-Value U-Factor U-Factor Sourcell <br /> N 2'A1.1,A9.1 0.370 <br /> o c <br /> o .§ <br /> N '[ -'pair.' <br /> CD 0 <br /> CL <br /> 0 0 <br /> p <br /> Solar Heat Gain Coefficient(SHGC) U-Factor for Prescriptive Compliance <br /> Projection Orientation <br /> Factor(PF) (N or Assembly Assembly <br /> Provide ID from window schedule and description if applicable12 SEW)13 SHGC14 U-Factor U-Factor Source" <br /> � I <br /> 2 <br /> 0 <br /> Z <br /> c • <br /> O m <br /> 4) (9 <br /> • N <br /> u- <br /> UO <br /> r <br /> • To <br /> N <br /> 2 <br /> C <br /> U) <br /> • N <br /> _c <br /> H <br /> Y — <br /> Cn Q <br /> Note 1-Insulation that is continuous except for fasteners may be entered here if the cross-sectional area of metal penetration through otherwise <br /> continuous insulation is less than 0.12%. <br /> Note 2-Alternate prescriptive continuous insulation R-values per Table C402.1.4,Footnote F may be used if the cross sectional area of metal <br /> penetrations exceeds 0.04%but is less than 0.12%. Calculations are required to use these alternate R-values. <br /> Note 3-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Specify the <br /> table number or calculation page number. <br /> Note 4-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies. <br /> Note 5-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 6-Proposed CMU mass walls in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target prescriptive <br /> U-value of 0.104. <br /> Note 7-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 8-Refer to Table C402.1.3, Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. <br /> Note 9 -Prescriptive slab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br /> Note 10-Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 11-Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 12-Refer to Equation C4-6 Projection Factor Calculation. <br /> Note 13-N=Oriented within 45 degrees of true north,SEW=All other orientations. <br /> Note 14-Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating. which includes the glazing and frame, or <br /> shall be the default value per Section C303.1.3. <br /> Note 15-List all above-grade Group R mass walls and steel frame walls in Group R ails section. List commercial above grade walls and all other <br /> Group R above grade walls in Opaque Walls-Above Grade. //� <br />
The URL can be used to link to this page
Your browser does not support the video tag.