My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 100TH ST SW AD SYSTEMS 2022-03-07
>
Address Records
>
100TH ST SW
>
2201
>
AD SYSTEMS
>
2201 100TH ST SW AD SYSTEMS 2022-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 2:19:18 PM
Creation date
3/2/2022 2:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
2201
Tenant Name
AD SYSTEMS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: AD Systems Warehouse Addition Date 08/11/2017 <br /> Fenestration Area as%gross above-grade wall area 0.3% Max.Target: 30% For Building Department Use <br /> Skylight Area as%gross roof area 0.9% Max.Target: 3% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch. ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x F SHGC x Area(A)= SHGC x A <br /> 0.35 183 64.1 <br /> SHGC 0.35 <br /> Skylight Totals 183.0 64.1 <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch. ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> PF<0.2 0.40 <br /> 0.25PF<0.5 0.48 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A).SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID Category <br /> PF<0.2 0.53 <br /> 0.25PF<0.5[ 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) I 183.0 64.1 <br /> "_ess proposed vertical fenestration here than ENV-UA: Add 48.0 <br /> Component Performance Compliance (SHGC) <br />
The URL can be used to link to this page
Your browser does not support the video tag.