My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 100TH ST SW AD SYSTEMS 2022-03-07
>
Address Records
>
100TH ST SW
>
2201
>
AD SYSTEMS
>
2201 100TH ST SW AD SYSTEMS 2022-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 2:19:18 PM
Creation date
3/2/2022 2:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
2201
Tenant Name
AD SYSTEMS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans Lnecklist, pg. 2 ENV-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 <br /> Project Title: AD systems Warehouse addition Date 08/11/2017 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> C103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll-up/sliding) <br /> yes C402.4.4 Opaque doors on wall sections or in door schedules-applies to doors with less than 50% <br /> glazed area <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> na C402.2.5 unconditioned space Indicate framing material on floor sections; <br /> insulation Indicate material density category and weight of qualifying mass floors <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> yes C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required <br /> C303.2.1 insulation distance from top of slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> Radiantly heated detail; <br /> na C402.2.6 slab-on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> C303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> na C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> C402.4.1 Provide calculation for total vertical fenestration area as a percentage of <br /> Vertical fenestration <br /> yes C502.2.1 maximum area gross above grade wall area(WWR)for new construction,additions and <br /> C503.3.2 alterations In ENV-SUM <br /> Provide calculations showing that the percentage of overall conditioned <br /> floor area within daylight zones is equal to or greater than 50%in 1&2 <br /> story builidngs:OR <br /> Provide calculations showing that the percentage of overall net floor area <br /> Increased within daylight zones is equal to or greater than 25%in buildings 3 stories <br /> C402.4.1.1 prescriptive or more;include the gross floor area and list of spaces omitted for the net <br /> na C405.2.4.1 maximum vertical floor area; <br /> C502.2.1 fenestration area <br /> C503.3.2 with daylight zones Note in envelope plans that all lighting fixtures located within daylight <br /> and controls zones shall be provided with daylight responsive controls per WSEC <br /> Section C405.2.4.1;indicate method of control in lighting fixture schedules <br /> Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> [nueasea Indicate high performance U-factors and SHGC values in fenestration <br /> C402.4.1.3 prescriptive schedules; <br /> na C502.2.1 maximum vertical <br /> fenestration area If applicable,provide area-weighted U-factor calculation(s)used for <br /> C503.3.2 with high- multiple fenestration elements within the same fenestration category per <br /> narfnrmanna nla7inn Table C402.3 <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served <br /> C402.4.1.4 maximum vertical by a dedicated outside air system(DOAS)that delivers ventilation air <br /> na C403.6 fenestration area without requiring operation of the heating/cooling system per Section <br /> with DOAS C403.6 <br /> mechanical systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be used <br /> na C402.1.5 fenestration target to account for vertical fenestration area in excess of the prescriptive <br /> area adjustment maximum allowed <br /> C402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof <br /> yes C502.2.2 area area(SRR)for new construction,additions and alterations in ENV-SUM <br /> C503.3.3 <br /> na C402.1.5.2 Roof/skylight target Indicate if component performance with target area adjustment will be used <br /> area adjustment to account for skylight area in excess of the prescriptive maximum allowed <br /> Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC and If applicable,provide area-weighted U-factor calculation(s)used for <br /> na C402.4.3 VTfor all fenestration multiple fenestration elements within the same fenestration category per <br /> C303.1.3 assemblies Table C402.3 <br /> Indicate if values are NFRC or default;if default then specify frame type, <br /> glazing layers,gap width,low-e coatings,gas-fill <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> na C402.4.3 provide projection factor calculations(Equation C4-6)and associated <br /> devices minimum SHGC for north and non-north orientations <br />
The URL can be used to link to this page
Your browser does not support the video tag.