Laserfiche WebLink
0 <br />• <br />SAC /lE6�0ELE PLA��E2964:$ <br />DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a) to <br />tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br />required, select the box next to (b) and (c) to acknowledge that plan review is required and the electrical plans have been provided <br />with this permit application. <br />* If item (a)-(ii, iii, or v) is selected, the work must also comply with section (a)-(vii). See arrow flow chart below. <br />I(3) Electrical plan review. <br />® (a) Electrical plan review is not required for: <br />❑ (i) Low voltage systems; <br />❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br />❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br />involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br />(iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution system <br />❑ does not include: <br />(A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br />(B) An essential electrical system defined in NEC 517.2; or <br />(C) A required fire pump system. <br />(v) Modifications to existing electrical installations where all of the following conditions are met: <br />(A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br />250 volts or for lighting circuits not exceeding 277 volts to ground; <br />(B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br />(C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br />and <br />(D) Service or feeder load calculations are increased by 5% or less. <br />(vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s) with a total <br />❑ rating of 9600 watts or less. <br />(vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered, the following must be available <br />❑ to the electrical inspector before the work is initiated: <br />(A) A clear and adequate description of the project's scope; <br />(B) A load calculation(s); <br />(C) What the load changes are, providing both before and after panel schedules as needed; and <br />(D) Provide information showing that the service and feeder(s) supplying the panel(s) where the work is <br />taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br />for that supply. <br />NOTE: Electrical plan review is not required for "Medical, dental, and chiropractic clinic" of which is a clinic or <br />❑ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br />(1)(c)(xii). <br />(b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br />® <br />occupancies defined in this chapter. <br />® (c) If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br />Taliie 900-1 <br />Health or Personal Care Facilities <br />Health:.dr Personal Care Facility: <br />. ... T}P .. - <br />Plan: ReView' <br />Required. . <br />i-ioscita <br />Wes <br />�9utsin hcme:un{rarlong=zeri <br />care�u^it <br />Yes <br />boarding home <br />Yes <br />F i�EeA la �ing:fa. {-ity' <br />ya= <br />nrlvate a;cohofmm ospital <br />Yes <br />orrs`a[= I.Gicniar c isosptiat <br />Yes <br />tisaterniv hame <br />yes <br />r".rrshi or}surg -f acujtl <br />Yes <br />Rcnat remodia ysis clinic <br />1`es <br />�esioent al treatmentfaa:siy <br />YF's <br />rhanceds rvicefaality. <br />YQ- <br />hLii31*' e5{Ci2 [tidal r h1 I�Ii ILatIQR. <br />C$nLe;: <br />Yes <br />Table.900-2 <br />Educational, arid instil ftional Faerlities, Places P..Assernhly, or Other Facilities. <br />Ed;ucati4nal' Institutional;,oY <br />Other FacilItlr Tykes: ' <br />Plan Rerigiri: <br />Rec7uirel <br />Eatscatiaraa; <br />y Cy: <br />ln-titui=,a;a,[ <br />Yea <br />%tr�ies;to Tables;�00�� arid.900.2.. <br />� ..city authari�ed to da efncfrtcal-ii�sp :ctiar <br />rna5r regyi{ e ptan':reyiew Qrl faci;ity type=_ riot <br />revaetEtt by the sl:epartmeif. <br />/)� PERMIT <br />Page 2-Plan Review <br />