My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8215 BROADWAY CROWN CASTLE ANTENNA 2022-03-23
>
Address Records
>
BROADWAY
>
8215
>
CROWN CASTLE ANTENNA
>
8215 BROADWAY CROWN CASTLE ANTENNA 2022-03-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 1:13:14 PM
Creation date
3/17/2022 11:42:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8215
Tenant Name
CROWN CASTLE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8" PVC PLUG <br />-- TO ANTENNA HYBRID CABLE-- TO ANTENNA HYBRID CABLE - 8" PVC PLUG CPLG. (THRD.) <br />(0-0 <br />T/FINISH GRADECOPPER/GALVANIZED GROUND BAR — COPPER/GALVANIZED GROUND BAR <br />0 0 o O O O o 0 0 0 0 0 0 0 0 0 0 O oO O O O0 0 0 000000 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 <br />0 0 0 0 0 0 0 0 0 0 0 0000 0 O 0 o Q 00 0 00000 0 0 0 0 0 0 O° N SUBGRADE <br />---- 2 SOLID TINNED COPPER z I --- #2 SOLID (TEST LOOP) <br />CONDUCTOR TO TOWER/SHELTER z ro /--- NOTCH SIDES OF 8" PVC SCH 40 PIPE <br />--- TWO HOLE LONG BARREL--- TWO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYP. FOR m a TO ALLOW EXIT/ENTRANCE OF <br />COMPRESSION LUG (TYP) (TYP) BOTTOM GROUND BAR ONLY) o EXOTHERMIC WELD -- GROUND RING WIRE <br />w <br />NOTES. NOTES: <br />II I —III —III— —I I —III— I I�)AI I- <br />i, DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 6\ <br />\ �--- TRENCH BOTTOM <br />2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). <br />3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER, MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. 2/0 TINNED CU EXTERNAL <br />CADWELD TEST LOOP TO TOWER GROUND RING WIRE <br />GROUND RING WIRE <br />NOTES: --- 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD <br />1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE <br />VERTICAL <br />2. GROUND WIRE SHALL BE MIN. 48" BELOW GRADE OR 6" BELOW FROST LINE. <br />(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) <br />ANTENNA SECTOR GROUND BAR DETAIL <br />SCALE: NOT TO SCALE <br />(—?-)TOWER/SHELTER GROUND BAR DETAIL <br />� SCALE: NOT TO SCALE <br />--- STAINLESS STEEL BOLT <br />(TYP) <br />TO TOWER MOUNTED EQUIPMENT <br />--- STAINLESS STEEL <br />(TYP) <br />FLAT WASHER <br />TO ANTENNA -� <br />MONOPOLE <br />2-HOLE CRIMP/ ----�\ <br />(TYP) <br />CE <br />COMPRESSION <br />N <br />-- ANTENNA GROUND BAR <br />CONNECTOR <br />LOCATED AT MCL <br />\ <br />i I (BONDED TO TOWER STEEL) <br />----- GROUND <br />BAR <br />STANDARD CABLE ------- <br />I I - 2 HOLE LUG (TYP) <br />GROUND KIT (TYP) <br />/ice <br />-_� <br />-- STAINLESS STEEL <br />/ <br />/ FLAT WASHER <br />#6 STRANDED CU WIRE WITH- <br />STAINLESS STEEL �-�= <br />/ (TYP) <br />GREEN, 60OV, THWN <br />I <br />BELLVILLE WASHER <br />��-- STAINLESS STEEL NUT <br />INSULATION (OR AS PROVIDED <br />(TYP) <br />(TYP) <br />WITH GROUND KIT) (TYP) <br />SINGLE CONNECTOR AT GROUND BARS <br />�--- STAINLESS STEEL BOLT <br />MECHANICAL CONNECTION <br />/ <br />(TYP) <br />-- STAINLESS STEEL <br />••\ CABLE GROUND BAR WITH <br />FLAT WASHER <br />HYBRID CABLE-- <br />1\ <br />NBOTTOM <br />(TYP FOR ALL) <br />OECTED <br />DIRECTLINSULATY TO THE <br />F MONOPOLE. SEE NOTE 1. <br />DRAGON TOOTH WASHER <br />(TYP) <br />� <br />„_, �,�,,,, <br />_ -STEEL <br />TO BTS EQUIPMENT VIA ----- <br />TRAY OR ICE BRIDGE <br />2/0 TINNED BARE <br />COPPER WIRE 2-HOLE CRIMP/ <br />MONOPOLE PIER COMPRESSION <br />--5-------- GROUND WIRE CONNECTOR <br />GROUND WIRE- •, 1 <br />NOTE 3 \ <br />INSPECTION WELL-\ SEE NOTE 3 <br />_ _ — _ • ,• <br />EXOTHERMIC WELD (TYP) <br />NOTES: <br />1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA <br />LOCATIONS AND CONNECTION ORIENTATION. CABLES EXCEEDING 200 FEET ON THE TOWER <br />SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. <br />2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. <br />TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. <br />3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE <br />RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. <br />��TYPICAL ANTENNA CABLE GROUNDING <br />, SCALE: NOT TO SCALE <br />STAINLESS STEEL <br />FLAT WASHER <br />(TYP) <br />STAINLESS STEEL -----i - STAINLESS STEEL NUT <br />BELLVILLE WASHER (TYP) <br />(TYP) <br />SINGLE CONNECTOR AT STEEL OBJECTS <br />STAINLESS STEEL — <br />SELF -DRILLING--- STAINLESS STEEL <br />METAL SCREW FLAT WASHER <br />(TYP) �\ / (TYP) <br />2-HOLE CRIMP/ ---- <br />COMPRESSION <br />CONNECTOR <br />DRAGON TOOTH --- METALLIC OBJECT <br />WASHER <br />(TYP) <br />SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS <br />�-� HARDWARE DETAIL FOR EXTERIOR CONNECTIONS <br />SCALE: NOT TO SCALE <br />(i� INSPECTION WELL DETAIL <br />�SCALE: NOT TO SCALE <br />r— 6" WIDE METALLIC HTEL <br />GRADE % WARNING/LOCATOR TAPE AT <br />12" DEPTH <br />N <br />O <br />z <br />z <br />2: <br />w ciU EXOTHERMIC WELD <br />o r_ <br />N_i-------�--�--------------� <br />\ GROUND RING #2 COPPER WIRE <br />SOLID, TINNED FOR CARRIER AND ICE <br />BRIDGE GROUND LOOP <br />\--- GROUND RING 2/0 FOR <br />TOWER GROUND LOOP <br />-- GROUND ROD COPPER <br />CLAD STEEL ROD W/MIN. <br />5/8 0 x 10'-0" LONG <br />NOTES: <br />1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE <br />VERTICAL <br />2. GROUND WIRE SHALL BE MIN. 48" BELOW GRADE OR 6" BELOW FROST LINE. <br />(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) <br />ROD DETAIL <br />�/ SCAOLE DNOT TTO SCALE <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />JURISDICTIONAL APPROVAL: <br />verizon <br />3245 158TH AVENUE. MS 231 <br />BEI,LEVUE WA 98008 <br />CCROWN <br />.,,,� CASTLE <br />1505 WESTLAKE AVENUE; NORTH, SLTTE 800 <br />SEA`f T.E, WA 98109 <br />Croup <br />EA&W-ing• Coftilft <br />Engn Gering with Precision, Pace and Passion. <br />675 Pratn Avenue <br />T-Ioffntiam <br />n Estatcs, IL 60192 <br />T: 224.293.6333 I": 224.293.6444 <br />wtengincecing.com <br />©COPYRIGI I'I 2021 TIES lY,'-T GROUP, LLC <br />VERIZON SITE NUMBER: 471496 <br />B U #: 824022 <br />FEELY <br />8215 BROADWAY <br />EVERETT,WA 98203 <br />AMENDMENT 60'-O" MONOPOLE <br />ISSUED FOR: <br />RF.V <br />DA'I'F <br />DR%VN <br />DESG2IITION <br />DFS./Q <br />A <br />U4/7A/21 <br />PRELIMINARY <br />JKR <br />0 <br />FI'_VALS <br />JRR <br />1 <br />L <br />L <br />REVISIONS <br />JKR <br />L4tS. �vl1;N <br />N 1S A \ tof wm OF 1 AW I OR -i.Nl <br />UNLESS TI-IFY 1RE.ICLINGL1NDER'1T$DIRLlT <br />OP A LICENSED PROI'LSSIONAL E NGINL P_R. <br />TO 4LTER'ITTIC DOCI TMRNT <br />SHEET NUMBER: REVISION: <br />G-1 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.