GENERAL NOTES <br />1. ALL WORK SHALL COMPLY WITH THE ANSI/TIA-222-H, ANSI/ASSP A10.48, AND ANY OTHER GOVERNING BUILDING CODES AND OSHA <br />SAFETY REGULATIONS. <br />2. ALL WORK INDICATED ON THE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS EXPERIENCED IN TELECOMMUNICATIONS <br />TOWER, POLE AND FOUNDATION CONSTRUCTION. <br />3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND FABRICATION OF ALL MISCELLANEOUS PARTS (SUCH AS SHIMS), <br />TEMPORARY SUPPORTS, AND GUYINGS, ETC., PER ANSI/ASSP A10.48, TO COMPLETE THE ASSEMBLY AS SHOWN IN THE DRAWINGS. <br />4. CONTRACTOR SHALL PROCEED WITH THE INSTALLATION WORK CAREFULLY SO THE WORK WILL NOT DAMAGE ANY EXISTING CABLE, <br />EQUIPMENT OR THE STRUCTURE. <br />5. THE USE OF GAS TORCH OR WELDER, ARE NOT ALLOWED ON ANY TOWER STRUCTURE WITHOUT THE CONSENT OF THE TOWER <br />OWNER. <br />6, GENERALLY THE CONTRACTOR IS RESPONSIBLE TO CONDUCT AN ONSITE VISIT SURVEY OF THE JOB SITE AFTER AWARD, AND <br />REPORT ANY ISSUES WITH THE SITE TO TES BEFORE PROCEEDING CONSTRUCTION. <br />7. IT IS THE RESPONSIBILITY OF THE GC TO VERIFY THAT THERE IS NO INTERFERENCES (WITH SAFETY CLIMB BRACKETS, TRANSMISSION <br />LINES, ETC.) PRIOR TO MOBILIZATION AND INSTALLATION OF THESE MODIFICATIONS. <br />8. PLEASE NOTIFY TES IMMEDIATELY IF ANY INSTALLATION ISSUES OCCUR RELATED TO THIS DRAWING @ 972-483-0607 OR <br />EMAIL-TESORDERS@TESTOWER.US <br />FABRICATION <br />1. ALL STEEL SHALL MEET OR EXCEED THE MINIMUM STRENGTH AS SPECIFIED IN THE DRAWINGS. IF YIELD STRENGTH WAS NOT NOTED <br />IN THE DRAWINGS, CONTRACTORS SHALL CONTACT TES FOR DIRECTION. <br />2. ALL FIELD CUT EDGES SHALL BE GROUND SMOOTH. ALL FIELD CUT AND DRILLED SURFACES SHALL BE REPAIRED WITH A MINIMUM <br />OF TWO COATS OF ZINGA COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURER'S RECOMMENDATIONS. <br />WELDING <br />1. ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS AND IN ACCORDANCE WITH THE LATEST EDITION OF THE AWS <br />WELDING CODE D1.1. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER METAL, PER AWS D1.1, UNO. (E70XX UNLESS <br />NOTED OTHERWISE). <br />2. PRIOR TO FIELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING APPROX. 0.5" BEYOND THE <br />PROPOSED FIELD WELD SURFACES. <br />3. ALL WELDS SHALL BE INSPECTED VISUALLY. A MINIMUM OF 25% OF WELDS SHALL BE INSPECTED WITH DYE PENETRANT OR <br />MAGNETIC PARTICLE TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. 100% OF WELDS SHALL BE INSPECTED IF DEFECTS ARE <br />FOUND. <br />4. WELD INSPECTIONS SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR. <br />5. AFTER INSPECTION, ALL FIELD WELDED SURFACES SHALL BE REPAIRED WITH A MINIMUM OF TWO COATS OF ZINGA COLD <br />GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURER'S RECOMMENDATIONS, <br />BOLTED ASSEMBLIES AND TIGHTENING OF CONNECTIONS <br />1. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO THE PROVISIONS OF THE SPECIFICATIONS FOR STRUCTURAL JOINTS USING A325 <br />OR A490 BOLTS AS APPROVED BY THE RCSC. <br />2. FLANGE BOLTS SHALL BE TIGHTENED BY THE AISC "TURN -OF -THE -NUT" METHOD. THE FOLLOWING TABLE SHOULD BE USED FOR <br />THE "TURN -OF -THE -NUT" TIGHTENING. <br />3. SPLICE BOLTS AND ALL OTHER BOLTS IN BEARING TYPE CONNECTIONS SHALL BE TIGHTENED TO A SNUG -TIGHT CONDITION, <br />4. THE SNUG -TIGHT CONDITION IS DEFINED AS THE TIGHTNESS ATTAINED BY EITHER A FEW IMPACTS OF AN IMPACT WRENCH OR THE <br />FULL EFFORT OF AN IRONWORKER WITH AN ORDINARY SPUD WRENCH TO BRING THE CONNECTED PLIES INTO FIRM CONTACT. <br />5. HB HOLLO-BOLT SHALL BE INSTALLED PER ICC ESR-3330 INSTRUCTIONS. <br />VERIFICATION AND INSPECTION <br />1. IF APPLICABLE, VERIFICATION INSPECTION TO BE PERFORMED SHALL BE IN ACCORDANCE TO IBC-2018 SECTION 1705.2 FOR STEEL <br />CONSTRUCTION AND TABLE 1705.3 FOR CONCRETE CONSTRUCTION. <br />TABLE 8.2 NUT ROTATION FROM SNUG -TIGHT <br />CONDITION FOR TURN -OF -NUT PRETENSIONING°'b <br />DISPOSITION OF OUTER FACE OF BOLTED PARTS <br />BOLT LENGTH` <br />BOTH FACES <br />ONE FACE NORMAL TO <br />BOLT AXIS, OTHER <br />BOTH FACES SLOPED <br />NOT MORE THAN 1:20 <br />NORMAL <br />BOLT AXIS <br />SLOPED NOT MORE THAN <br />FROM NORMAL TO BOLT <br />1:20 d <br />AXIS d <br />NOT MORE THAN <br />4db <br />1/3 TURN <br />TURN 1/2 <br />/ <br />2 3 TURN <br />/ <br />MORE THAN 4db <br />BUT NOT MORE <br />1/2 TURN <br />2/3 TURN <br />5/6 TURN <br />THAN 8db <br />MORE THAN 8db <br />BUT NOT MORE <br />2/3 TURN <br />5/6 TURN <br />1 TURN <br />THAN 12db <br />° NUT ROTATION IS RELATIVE TO BOLT REGARDLESS OF THE ELEMENT (NUT OR BOLT) <br />BEING TURNED. FOR REQUIRED NUT ROTATIONS OF 1/2 TURN AND LESS, THE <br />TOLERANCE IS PLUS OR MINUS 30 DEGREES; FOR REQUIRED NUT ROTATIONS OF <br />2/3 TURN AND MORE, THE TOLERANCE IS PLUS OR MINUS 45 DEGREES. <br />b APPLICABLE ONLY TO JOINTS IN WHICH ALL MATERIAL WITHIN THE GRIP IS STEEL. <br />a WHEN THE BOLT LENGTH EXCEEDS 12d6, THE REQUIRED NUT ROTATION SHALL BE <br />DETERMINED BY ACTUAL TESTING IN A SUITABLE TENSION CALIBRATOR THAT <br />SIMULATES THE CONDITIONS OF SOLIDLY FITTING STEEL. <br />d BEVELED WASHER NOT USED. <br />SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, JUNE 30, 2004 <br />RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS <br />INSTALLATION TORQUE REQUIRED FOR HOLLO BOLTS AND AJAX BOLTS: <br />1. HB12 HOLLO BOLT: 59 FT-LBS <br />2. HB16 HOLLO BOLT: 140 FT-LBS <br />3. H820 HOLLO BOLT: 221 FT-LBS <br />4. M20 AJAX BOLT: 280 FT-LBS. <br />FIELD HOT WORK PLAN NOTES: <br />FOLLOWING GUIDELINES SHALL BE COMPLIED WITH: <br />1. CONTRACTOR'S RESPONSIBILITY TO COMPLETE A HOT WORK PLAN IF AWARDED PER CUSTOMER <br />SPECIFICATIONS GUIDELINES FOR WELDING, CUTTING & SPARK PRODUCING WORK. <br />2. HAVE A FIRE PLAN APPROVED BY THE CUSTOMER AND THEIR SAFETY MANAGEMENT DEPT. <br />3. CONTRACTOR MUST OBTAIN THE CONTACT INFO OF THE LOCAL FIRE DEPARTMENT AND THE 911 <br />ADDRESS OF THE TOWER SITE BEFORE CONSTRUCTION. <br />4, CONTRACTOR SHALL MAKE SURE THAT CELL PHONE COVERAGE IS AVAILABLE IN THE TOWER SITE. IF <br />CELL COVERAGE IS NOT AVAILABLE, AN IMMEDIATE AVAILABLE MEANS OF DIRECT COMMUNICATION WITH <br />THE FIRE DEPARTMENT SHALL BE DETERMINED PRIOR TO CONSTRUCTION START. <br />5. ALL CONSTRUCTION SHALL BE PERFORMED UNDER WIND SPEED LESS THAN 10 MPH ON THE GROUND <br />LEVEL. IF WIND SPEED INCREASE, CONTRACTOR MUST DETERMINE IF CONSTRUCTION SHALL BE <br />DISCONTINUED. <br />6. FIRE SUPPRESSION EQUIPMENT MUST BE MADE AVAILABLE ON SITE AND READY TO USE. <br />7. CONTRACTOR SHALL ASSIGN A FIRE WATCHER TO PERFORM FIRE -FIGHTING DUTIES. <br />8. ALL WELDERS SHALL BE AWS OR STATE CERTIFIED. THEY MUST ALSO BE EXPERIENCED IN WELDING ON <br />GALVANIZED MATERIALS. <br />9. IF IT IS POSSIBLE, ALL EXISTING COAX NEAR WELDING AREA SHALL BE TEMPORARILY MOVED AWAY <br />FROM THE WELDING AREA BEFORE WELDING THE PLATES. <br />10. PLEASE REPORT ANY FIELD ISSUE TO TES @ 972-483-0607. <br />CITY ®F EVERETT <br />REVIEWED FOR PERMIT <br />TES <br />Tower Engineering Solutions <br />1320 GREENWAY DRIVE, SUITE 600 <br />IRVING, TX 75038 <br />PH: 972 483-0607 <br />vreirizon <br />V1111W <br />TES JOB NO: <br />10049003 <br />CUSTOMER SITE NO: <br />471496-VZW <br />CUSTOMER SITE NAME: <br />TIMBER -HILL - A <br />8215 BROADWAY <br />EVERETT, WA 98203 <br />DRAWN BY:SP CHECKED BY: ID/CHLE <br />REV. DESCRIPTION BY DATE <br />A FIRST ISSUE SP 03 12 21 <br />0 <br />_ <br />A <br />SHEET TITLE: <br />GENERAL NOTES <br />This drawing/document is the property of <br />Tower Engineering Solutions, I.I.C. Information <br />contained herein is considered confidential in <br />nature and is to be used only for the <br />specific site that it was intended for. <br />Reproduction, transmission, publication or <br />disclosure by any method is prohibited <br />except by express written permission from <br />Tower Engineering Solutions, I.L.C. Without <br />exception, the information on this <br />drawing/document remains the property of <br />Tower Engineering Solutions, LLC. <br />SHEET NUMBER: <br />REV #: <br />GN-1 <br />0 <br />