My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
309 E CASINO RD VERIZON WIRELESS 2023-08-08
>
Address Records
>
E CASINO RD
>
309
>
VERIZON WIRELESS
>
309 E CASINO RD VERIZON WIRELESS 2023-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2023 10:22:17 AM
Creation date
3/17/2022 1:32:26 PM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
309
Tenant Name
VERIZON WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TELECOMMUNICATIONS WIRING COMPONENTS <br />(COAXIAL ANTENNA CABLE) <br />1. GENERAL <br />A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO <br />WORK SHALL BE NEW AND OF STANDARD COMMERCIAL QUALITY. <br />S. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER <br />TO GENERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT, <br />MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR IS RESPONSIBLE <br />FOR PICKUP AND DELIVERY OF ALL SUCH MATERIALS <br />C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT <br />DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR. <br />2. MATERIALS: <br />A. COAXIAL CABLE: <br />1. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS <br />AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS <br />WITH COAXIAL CABLES SUPPORTED AT NO MORE THAN T-0" O.C. <br />WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND <br />EQUIPMENT PER MANUFACTURERS' REQUIREMENTS. TERMINATE <br />ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF EQUIPMENT <br />LOCATION UNLESS OTHERWISE STATED. <br />2. ALL COAX RUN LENGTHS GREATER THAN 143 FEET SHALL BE 15/8" <br />AND IN LENGTH LESS THAN OR EQUAL TO 143 FEET SHALL BE 718". <br />3. ANTENNA AND COAXIAL CABLE GROUNDING <br />A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON <br />STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) <br />4. COAXIAL CABLE IDENTIFICATION <br />A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF <br />ANTENNA CABLING, PLASTIC TAGS SHALL BE USED AT THE <br />FOLLOWING LOCATIONS: <br />1. FIRST LOCATION IS AT THE END OF THE COAX NEAREST <br />THE ANTENNA (WHERE THE COAXIAL CABLE AND JUMPER <br />ARE CONNECTED). <br />2. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER <br />NEAR THE WAVEGUIDE ENTRY PORT. <br />B. USE ANDREW CABLE TIES (PT.927290) TO SECURE IDENTIFICATION TAGS. <br />5. TESTING <br />VERIZON WIRELESS SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO PERFORM THE <br />COAXIAL SWEEP TEST& REPORT. THE CONTRACTOR IS TO PROVIDE CLIMBER / QUALIFIED <br />PERSONNEL TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST IS <br />COMPLETE THE CONTRACTOR IS TO PROVIDE VERIZON WIRELESS A MINIMIM OF 48 HOURS <br />NOTICE PRIOR TO THE TIME OF THE SWEEP TEST. <br />ELECTRICAL NOTES <br />INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE <br />WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES AND REGULATIONS FOR INSTALLING <br />ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.EA. <br />S651401, I.C.EA. P81-570, & LOCAL PUD. <br />PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK <br />BOARD. <br />UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING <br />TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT <br />SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "1MDE SWEEP" <br />TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE FIGS, (OR PVC ENCASED IN 8"x18" RED <br />CONCRETE DUCTBANK). <br />CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL BE <br />RIGID STEEL AND COMPRESSION TYPE FOR EM.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL <br />STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. <br />WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. <br />PROVIDE HOPE PULLING HAND HOLES AS NEEDED. <br />CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE <br />INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO <br />GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE <br />DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO <br />PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO <br />REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL <br />EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO.OXY", <br />"NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED <br />ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL <br />ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTICORROSIVE AGENT SUCH AS LPS3 OR AS PER NOTE <br />6 ABOVE. <br />ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT <br />NUMBERS CONTAINED IN EACH BOX. <br />CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL TVSS. <br />CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. <br />WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL <br />UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. <br />VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED EQUIPMENT <br />SHELTER PACKAGE IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING <br />OF AIC TO ACCEPTABLE LEVELS. <br />UTILITY POINTS OF SERVICE AND WORK MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION <br />PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. <br />CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS <br />REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY. <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE <br />ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, <br />PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK <br />GROUNDING NOTES: <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION <br />SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO <br />EQUIPMENT IS NOT BLOCKED. <br />3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br />CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR <br />DAMAGE TO THE CONDUIT. <br />4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD) <br />5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) <br />HIGH PRESS CRIMPS. <br />6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL <br />SEPARATION OF S" FOR EVERY ADDITIONAL CONNECTION. <br />7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL <br />8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE 02 AWG TIN PLATED COPPER UNLESS OTHERWISE <br />INDICATED. <br />9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"- 10-FT. LONG (OR NOTED <br />OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE <br />OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. <br />10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK <br />CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />11. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45" BENDS <br />CAN BE ADEQUATELY SUPPORTED. <br />12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST <br />LINE. <br />13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-W FROM EQUIPMENT CONCRETE PAD, <br />SPREAD FOOTING, OR FENCE. <br />14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. <br />15.OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING <br />16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT <br />GROUNDING POINTS PROVIDED (2 MINIMUM) <br />17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br />18. CONTRACTOR TO VERIFY CURRENT GROUNDING STANDARDS PRIOR TO CONSTRUCTION. <br />c <br />0 <br />N <br />Lm <br />-4) <br />J4 SITE SOW <br />/Yale i .o4 Six <br />1133 164TH STREET SW <br />SUITE 202 <br />LYNNWOOD, WA 9W87 <br />OFFICE: (425) 77838M <br />JAYGNEfAWAVEARCH.COM <br />DATE- 2-18-21 <br />PREPARED BY- YML <br />APPROVED BY- JYS <br />SUBMITTALS <br />O <br />1401 <br />DATE <br />DESCRIPTION <br />2.18.21 <br />FINAL PERMIT <br />2-221 <br />REVISED PERMIT <br />128-21 <br />PREUMINARYPERMIT <br />RED <br />CT <br />2.18-21 <br />*lDyFWA"GTON <br />SEA- CASINO ROAD <br />(MOD.sm_saL-sues) <br />309 E CASINO ROAD <br />EVERETT WA 98208 <br />SHEET TITLE <br />GENERAL NOTES <br />SHEET NUMBER <br />sP-2 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.