Laserfiche WebLink
3/10/202.1 https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZl9zY29wZV9uZXdfaW50ZXJpb311NONwZF9hbHRlcm FOaW9uX2dOXzUwJnRmdj1sdGdfc2Nvc... <br />LIGHTING COMPLIANCE SUMMARY <br />2018 WSEC Compliance Forms for Commercial Buildines including Group R2, R3 & R4 over 3 stories and all RI Administered by: (02021 NEEA, All rights reserved <br />Project & Applicant <br />Information <br />Project Title <br />GO Everett WA - 2018 WSEC <br />For Building Department Use: I Date: Mar 10, 2021 <br />Project Address <br />10115 Evergreen way <br />Everett, WA 98204 <br />Applicant Name <br />Shaza Yacob <br />Applicant Phone <br />714-576-2547 <br />Applicant Email <br />syacob@coolsys.com <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />General Occupancy <br />All Commercial <br />General Building Use Type <br />Retail, Grocery/Supermarket <br />Building Cond. Floor Area <br />30,489 <br />General Project Types <br />Building Addition <br />Alteration <br />New Building or <br />Addition <br />Lighting Scope <br />g g P <br />Interior Lighting <br />Alteration <br />Lighting Scope <br />Interior Lighting <br />Project Cond. Floor Area <br />30,489 <br />Floors Above Grade <br />I <br />Compliance Method <br />Compliance Method 1 -General <br />Lighting Project Description <br />ALL LIGHTING SHALL BE REPLACED WITH NEW LED LIGHT FIXTURES. <br />Lighting Compliance Scope <br />Project a <br />J Type <br />Interior / Exterior <br />(Interior includes both interior & parking) <br />Luminaire Replacement Sc o a <br />P P <br />Com Nance Method <br />p <br />LPA Calculation <br />Adjustment <br />Compliance Verification <br />P <br />and Method <br />Alteration <br />Interior Lighting <br />50% or more replaced <br />Space by space <br />No Calculation Adjustments allowed <br />COMPLIES <br />Additional Efficiency <br />Options Included <br />Project Title GO Everett WA - 2018 WSEC Date Mar 10, 2021 _ 1, <br />Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES <br />Compliance Method Space by space LPA Calculation Adjustment none <br />Interior Lighting Power Allowance - Space by Space <br />General Space Type <br />Specific Space Type <br />Ceiling <br />Height (Ft) <br />Gross Interior Area (SF) <br />LPA (Watts/SF) <br />Total Watts Allowed <br />(SF x LPA x 1) <br />Total Proposed Watts <br />(f,PD + Display LPD) <br />Compliance Status <br />Corridors <br />General <br />554 <br />0.41 <br />227 <br />Electrical/mechanical <br />551 <br />0.43 <br />237 <br />Lobby <br />General <br />134 <br />0.84 <br />113 <br />Lounge/breakroom <br />General <br />169 <br />0.59 <br />100 <br />Office <br />Enclosed less than 250 sf <br />160 <br />0.74 <br />118 <br />Office <br />Enclosed less than 250 sf <br />100 <br />0.74 <br />74 <br />Restroom <br />General <br />148 <br />0.63 <br />93 <br />Storage room <br />General <br />13,032 <br />0.38 <br />4,952 <br />Storage room <br />General <br />1,337 <br />0.38 <br />508 <br />Retail <br />General sales <br />13,862 <br />1.05 <br />14,555 <br />Proposed Total LPD <br />20587 <br />Totals <br />20,977 <br />20,587 <br />1 COMPLIES <br />Proposed Lighting Power Density <br />Fixture Type <br />Fixture ID <br />Quantity of <br />Fixtures (#F) <br />Watts or <br />Wattage Limit <br />per Fixture <br />(WpF) <br />Total Linear <br />Feet (LF) <br />Watts per Linear <br />Foot (WpLF) <br />Total Watts <br />Proposed <br />(#F x WpF) or <br />(LF x Wp1.F) <br />Individual Fixtures <br />Horizontal surface -mount <br />Cl <br />17 <br />33 <br />561 <br />Horizontal surface -mount <br />V2 <br />4 <br />1 85 <br />340 <br />Horizontal surface -mount <br />C3 <br />2 <br />1 69 <br />138 <br />https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb311NONwZF9hbHRlcmF0aW9uX2d0XzUwJnRmdj1 sdGdfc2NvcGVfbmV3X21... 1/2 <br />