Laserfiche WebLink
ABBREVIATIONS <br />V ANGLE <br />R CENTER LINE <br />DIAMETER OR ROUND <br />P NUMBER OR POUND <br />PENNf <br />-L PERPENDICULAR <br />R PLATE <br />AS ANCHOR BOLT <br />AC ACOUSTICAL OR <br />A/C AIR, CONDITIONING <br />ACP ACOUSTICAL PANEL <br />ACT ACOUSTICAL TILE <br />ASH ADHESIVE <br />ADJ ADJACENT <br />ADJT ADJUSTABLE <br />AF ACCESS FLOOR <br />AFF ABOVE FINISH FLOOR <br />AL ALUMINUM <br />ALT ALTERNATE <br />AP ACCESS PANEL <br />APPROX APPROXIMATE <br />ARCH ARCHITECTURAL <br />ASPH ASPHALT <br />BD BOARD <br />BEDY BETWEEN <br />BLDG BUILDING <br />ELK BLOCK <br />ewe BUILDING <br />BM BEAM <br />BRG SEARING <br />Bar BOTTOM <br />BSMT BASEMENT <br />BUR BUILT UP ROOF <br />CAB CABINET <br />CB CATCH BASIN <br />CEU CEMENTIIOUS BACKER UNIT <br />GEN CEMENT <br />CER CERMC <br />CRA CUBIC FEET PER MINUTE <br />CFT CONOUCTIVE FLOOR TILE <br />OG CORNER GUARD <br />CHBD CHNH BOARD <br />CI CAST IRON <br />Cif CONTROL JOINT <br />CLF CHAIN LINK FENCE <br />OLD CEIUNG <br />CJ CONSTRUCTION JOINT <br />CIK rAUL10NG <br />CLO CLOSET <br />CAR CLEAR <br />CMU CONCRETE MASONRY UNIT <br />CWTI COUNTER <br />Go CLFANOUT <br />COL COLUMN <br />GONC CONCRETE <br />CONSIR CONSTRUCTION <br />COW CONTINUOUS <br />CORR CORRICOR <br />CPT CARPET <br />CT CERAMIC TILE <br />CTR CENTER <br />CY CUBIC YARD <br />DBL DOUBLE <br />DEPT .DEPARTMENT <br />GET DETAIL <br />OF DRINKING FOUNTAIN(W/O COOLER) <br />DIA DIAMETER <br />DIAL DIAGONAL <br />DIM DIMENSION <br />DISP DISPENSER <br />IN DOWN <br />DR DOOR OR DRAIN <br />DWR DRAWER <br />DS DOWNSPOUT <br />DIN DISHWASHER <br />DWG DRAWING <br />E EAST <br />EA EACH <br />ED EXPANSION BOLT <br />FJ EXPANSION JOINT <br />E_ ELEVATION <br />ELEC ELECTRIC <br />aw ELEVATOR <br />EM ENTRY MAT <br />OMER EMERGENCY <br />ENCL ENCLOSURE OR ENCLOSED <br />EP . ELECTRICAL PANEL <br />EWC ELECTRIC WATER COOLER <br />EPX EPDXY <br />TO EQUAL <br />EQPT EQUIPMENT <br />EST ESTIMATE <br />IX EXPANSION <br />EXIST EXISTING <br />IXT EXTERIOR <br />FA FIRE ALARM <br />FBO FURNISHED BY OTHERS <br />FCIC FURNISHED BY CONTRACTOR <br />INSTALLED BY CONTRACTOR <br />FCIY FACTORY <br />FD FLOOR DRAIN <br />FOR FOUNDATION <br />FE FIRE EXTINGUISHER <br />FEC FIRE EXTINGUISHER. CABINET <br />FIN FINISH <br />FL FLOOR <br />FLO FLASHING <br />FLUOR FLUORESCENT <br />FM FACTORY MUTUAL <br />Foe FACE OF CONCRETE <br />FOF FACE OF FINISH <br />FDIC FURNISH BY OWNER <br />INSTALL BY CONTRACTOR <br />F010 FURNISH BY OWNER <br />INSTALL BY OWNER <br />FDS FACE OF STUD <br />FS FULL SIZE <br />FT FEET <br />FIG FOOTING <br />FTC FURNISHED BY TENANT <br />INSTALLED BY CONTRACTOR <br />FRO FURNISHED BY TENANT <br />INSTALLED BY OWNER <br />FURR FURRING <br />FUT FURORE <br />FUTURE- FUTURE ROUGH IN ONLY <br />Rio <br />FX FIXED <br />G GAGE <br />GALV GALVANIZED <br />GB GRAD BAR OILGLASS OR GLAZING <br />CLBM GLU-LAM DEAN <br />GEN CONTR GENERAL CONRRPCTOR <br />GND GROUND <br />OR GRADE <br />GINS GYPSUM WALL BOARD <br />HB HOSE BIB <br />HC HOLLOW CORE OR HANDICAP <br />HDR HEADER <br />HDWD HARDWOOD <br />HOWE HARDWARE <br />HM HOLLOW METAL <br />HORIZ HORIZONTAL <br />HP. HOUR <br />HF HEIGHT <br />HTG HEALING <br />WAD RFATING/VENTILIATION/ <br />AIR CONDITIONING <br />HINH HOT WATER HEATER <br />ID INSIDE DIAMETER/ <br />DIMENSION <br />IG INSULATED GLAZING <br />IHM INSULATED HOLLOW METAL <br />IN INCH <br />INCL INCLUDE <br />INSUL INSULATION <br />INT INTERIOR <br />JAN JANITOR <br />Jr JOINT <br />KIT IOTCHEN <br />KO KNOCK OUT <br />KS KNEE SPACE <br />TAM LAMINATE <br />LAV LAVATORY <br />LB LAG BOLT <br />LF UNEAL FOOT <br />LG LENGTH <br />LH LEFT HAND <br />LINO UNOLEUM <br />LKR LOCKER <br />LT LIGHT <br />MACH MACHINE <br />MAR MATERIAL <br />MAX MAXIMUM <br />MECH MECHANICAL <br />MET OR Atli METAL <br />MEZZ MEZZANINE <br />MFR MANUFACTURER <br />MH MANHOLE <br />MIN MINIMUM <br />MIS LURROR <br />MSO NISCEIIANEOUS <br />MILD MOLDING ` <br />MRGWB MOISTURE RESISTANT GYP RD <br />MID MOUNTED <br />MULL MULLION <br />N NORTH <br />NIC NOT IN CONTRACT <br />NO/; NUMBER <br />NOM NOWNAL <br />MS NOT TO SCALE <br />OA OVERALL <br />00 ON CEDER <br />OD OUTSIDE DIAMETER/ <br />DIMENSION <br />OFF OFFICE <br />OH OVERHEAD <br />OPH OPPOSITE HAND <br />OPNG OPENING <br />Opp OPPOSITE <br />PERP PERPENDICULAR <br />PFN PREFlNISHED <br />PL PLATE OR PROPERTY LINE <br />P UM PLASTIC LAMINATE <br />PLYWD PLYWOOD <br />PNL PANEL <br />PNT PAINT <br />PR PAIR — - <br />PS PAINT SYSTEM <br />PSF POUNDS PER SQUARE FOOT <br />PSI POUNDS PER SQUARE INCH <br />PT PRESSURE TREATED <br />PIT) PAPER TOWEL DISPENSER <br />PTD/R PAPER TOWEL DISPENSER <br />AND RECEPTADIE <br />PIN PARTITION <br />PTR PAPER TOWEL RECEPTACLE <br />PANT PAVEMENT <br />QT QUARRY TILE <br />R RISER <br />RA RETURN AIR <br />RAD RADIUS <br />RB RESIDENT BASE <br />R&S ROD & SHELF <br />RD ROOF DIAN <br />RD/O ROOF DRAIN OVERFLOW <br />REPAIR REINFORCING BAR <br />REF REFERENCE <br />REFR REFRIGERATOR <br />REINF REINFORCED <br />REDID REQUIRED <br />REV REVISION <br />RH RIGHT HAND OR ROBE HOOK <br />RESIL RESILIENT <br />RA1 ROOM <br />RO ROUGH OPENING <br />Rr RESILIENT TILE <br />RUB RUBBER <br />RVS REVERSE <br />RW RAIN WATER <br />RWL RAIN WATER LEADER <br />S SOUTH <br />Be SOLID CORE <br />BCD SEAT COVER DISPENSER <br />SCHD SCHEDULE <br />SD SOAP DISPENSER OR <br />SECT SECTION <br />SF SQUARE FEET <br />SHIG SHEATHING <br />SIM SIMILIAR <br />SK SINK <br />SLR SEALER <br />END SANITARY NAPKIN <br />DISPENSER <br />SNR SANITARY NAPKIN <br />RECEPTACLE <br />SNT SEALANT <br />SPEC SPECIFICATION <br />SQ SQUARE <br />SST STAINLESS STEEL <br />SSK SERVICE SINK <br />ST STONE/SFONE TILE <br />STA STATION <br />SIC SOUND TRANSMISSION <br />CUSS <br />BID STANDARD <br />SR STEEL <br />STOR STORAGE <br />STRL STRUCTURAL <br />SUSP SUSPENDED <br />SV SHEET VINYL <br />SM SYMMETRICAL <br />T TREAD <br />TB TOWEL BAR <br />T&B TOP & BOTTOM <br />TO TEMPERED GLASS <br />THK THICK <br />THR THRESHOLD <br />TIG TEMPERED INSULATED <br />GLAZING <br />TO TOP OF <br />TOC TOP OF CONCRETE <br />TOP TOP OF PAVEMENT <br />ITS TOP OF STEEL <br />TOSL TOP OF SLAB <br />TOW TOP OF WALL <br />TPO TOIf 7 PAPER DISPENSER <br />TPH TOILET PAPER HOLDER <br />WIN TOILET PARIRWN <br />TS TUBULAR STEEL <br />TV TELEVISION <br />TYP TYPICAL <br />UL UNDERWRITERS LABORATORY <br />II UNFINISHED <br />LION UNLESS OTHERWISE NOTED <br />UR URINAL <br />VAR VARIES <br />VCT VINYL OOMPOSMON TILE <br />VERT VERTICAL <br />VEST VESTIBULE <br />MAN VINYL <br />VWC VINYL WALL COVERING <br />W WEST <br />W/ WITH <br />W/o WITHOUT <br />WC WATER CLOSET <br />WD WOOD <br />WF WIDE FLANGE <br />WG WRE CLASS <br />WP WATER PROOF <br />WR WATER RESISTANT <br />WSCT WAINSCOT <br />W! WEIGHT <br />XEJR TRANSFORMER <br />YO YARD <br />SYMBOLS <br />A <br />�l COLUMN LANE/GRID LINE <br />DOOR NUMBER <br />CORRESPONDS TO ROOM ENTERING <br />nY NOTE <br />WI I I-"1=i PARTITION TYPE <br />RjY�IIylSI0N N RMljl <br />TENS ON <br />CLOUD AROUND REVISION <br />MATCH LINE <br />- - SHADED PORTION IS THE SIDE <br />CONSIDERED <br />WO POINT, CONTROL POINT <br />OR DATUM POINT <br />1492 EQUIPMENT NUMBER. <br />X IUILDNG SECTION <br />(�(• SECTION IDENIIFlGTION <br />SHEET 1VHBRE SECTION IS DRAWN <br />DETAIL SECTION <br />SECTION TIT ITGTON <br />SHEET WHERE SECTION IS DRAWN <br />X DETAIL ORI�ENIARC O PI <br />�. DETAIL IDENTIFICATION <br />SHEET WHERE DETAIL IS DRAWN <br />ND YY MNDDW BUG <br />A INTERIOR EIFVATIONO <br />ELEVATION IDENTIFICATION <br />SHEET WHERE ELEVATION IS <br />DRAWN <br />TR.DOM IDENTIFICATION <br />IIfIF2 ROOM NAME <br />ROOM $— ROOM N0, <br />Ell FINISHED CEUNG HEIGHT <br />._ - - -- <br />PROPERTY LINE <br />78 <br />NEW OR FINISHED CONTOURS <br />EXISTING CONTOURS <br />-- 71 <br />S50 <br />��. <br />TOP OF WALL <br />6� <br />SP•, TOP OF CURB <br />,5p <br />SQ" <br />TOP OF PAVENENI <br />P CI <br />N <br />XV <br />PROJECT NORTH <br />9'-0' <br />DENOTES CHANGE IN <br />7,d' <br />ELEVATION <br />2 <br />FINISHSYMBOL <br />GENERA, NOTES <br />I. THE GENERAL CONTRACTOR SHAIl BE SI Y AND COMPLETELY RESPONSIBLE FOR CONDRTIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL <br />AND <br />PENNONS, PROPERTY, AND FOR ALL NECFSSARf ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH OSHA <br />SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SIDE OBSERVATIONS ARE NOT INTENDED TO INCLUDE RENEW OF THE ADEQUACY OF <br />THE CONTRACTOR'S SAFETY MEASURES. <br />2 EACH CONTUACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN <br />OBJECTIONS PRIOR TO BIDDING, IF THE COW —OR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND <br />SPECIFICATIONS. <br />3. THE GENERAL CONTRACTOR SHAH COORDINATE THEIR WORK USE THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED <br />ITEMS, WHICH ARE BEING DONE BY OTHERS. <br />4. THE GENERAL CONTRACTOR SHALL VERIFY AIL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIAIEEY OF ANY <br />DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHNL BE HELD UNTIL SUCH <br />DISCREPANCIES ARE RESOLVED. <br />5. SEPARATE PERMITS, WflEN REQUIRED AND/OR WHEN WORK ITEMS ARE DESIGN/BUILD IN MATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR <br />MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM, DESCRIPTIVE, DETAILED DESIGN AND REQUIRED SUBMITTAL DOCUMENTS <br />INFORMATION SNALL BE PROVIDED FOR RENEW BY THE REGULATING AURHORRIES AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO <br />ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN/BUILD FIRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND. OBTAIN <br />PERMIT FROM THE AUTHORITY HAVING JURISDICTION FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. ALL WORK SHALL COMPLY WITH <br />CURRENT GOVERNING CODES. <br />6, SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL BE PERFORMED Of INSPECTORS APPROVED BY THE BUILDING OFFICIAL <br />- <br />7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED. PERMITIW, STAMPED <br />PLANS ARE TO RUM ON SITE AT ALL TIMES. ANY MODIFICATIONS TO WORK SHALL BE INDICTED ON FIELD.'AS-BUST SET OF DOCUMENTS. <br />8. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. <br />9. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. <br />10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR <br />WORK. IF QUESTIONS CAN NOT BE RESOLVED IN INNS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. <br />11. GENERAL CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT WITH DEEAILED CRITIC. PATH SCHEDULE FOR RENEW AND APPROVAL PRIOR TO START <br />OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER AND ARCHITECT. <br />WITH <br />12. ALL WORK AND MATERIALSSHALL BE IN FULL ACCORDANCE WITH CURRENT CODES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED <br />AS TO PERMIT WORK WHICH IS NOT CONFORMING TO CURRENT GCVERNING CODES. <br />' <br />13. PROTECTIVE MEASURES SHALL BE TALON BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. <br />14. THE CONTRAEFUR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTIUIY SERVICE PROVIDERS. PUBLIC AND/OR PRIVATE <br />15. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10'-U O.C. AND ALSO AT ANY LOCATION WHERE WAIL FRAMING PENETRATES <br />CEILINGS. REFER TO IBC SEC. 708 FIRE BLOCKING AND DRAFT STOPS FOR CONSTRUCTION. <br />16. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE AANCENT TO AND AFFECTED BY NEW CONSTRUCTION. <br />17. PRIOR TO FINAL INSPECTION, A CERTIFICATE OF CONSTRUCTION COMPLIANCE SHALL BE READY FOR THE INSPECTOR. THE CERTIFICATE SHU STATE <br />'BASED UPON PERSONAL KNOWLEDGE, THAT THE WORK APPEARS TO HAVE BEEN PERFORMED, AND THE MATERIALS USED AND INSTALLED APPEAR IN <br />L <br />EVERY MATERIAL RESPECT IN COMPLIANCEWITH THE PLANS'. THE CERTIFICATE MUST BE SIGNED BY ONE OR MORE OF THE FOLLOWING: <br />A� T <br />//�� <br />(A) OWNER. (B) GENERAL CONRRACFOR, (C) AN APPROVED INDEPENDENT INSPECTOR OR INSPECTION AGENCY. <br />'a•� <br />l§, <br />4 V��" <br />* <br />IS. ASOESTOC AND H A CODS W [TF IXCLUSION: <br />THE ARCHITECT HEREBYSTAIRS, ANDTHE OWNER ACKNOWLEDGES. THAT THE ARCHITECT PAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, <br />�Vi <br />I <br />(AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM .d <br />z v�4$10 <br />PROFESSIONAL SERVICES, INCLINING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND <br />V <br />RELATED TO THE INVESTIGATION DEFECTION. <br />19, PROVIDE FIRE EXTINGUISHERS WITH A MINIMUM RATING OF 2A:106:C IN QUANTITY AND LOCATIONS AS DIRECTED BY THE FIRE MARSNdL, MINIMUM OF <br />4/0 <br />ONE UNIT PER 3,000 SF AND NO MORE TWIN 75 FOOT TRAVEL DISTANCE TO ANY FIRE EXTINGUISHER <br />20, PROVIDE APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE <br />PUBLIC SAFETY COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING PER INTERNATIONAL FIRE CODE (IFC) SECTION <br />510.1. <br />C.:! <br />EGRESS SUMMARY LEGEND <br />A MAX. TRAVEL, DISTANCE 200' (TABLE 1016.1 - S-1 OCCUPANCY) gff NEW EXIT SIGN W/EMERGENCY POWER TO MEET IBC <br />250' Off ACCESS DISTANCE INCREASE WHEN FULLY SPRINKLED SECTION loll <br />B. MAX. COMMON PATH OF EGRESS TRAVEL' 75' (1014.3) Too' INCREASE PHEN FULLY SPRINKLED F-R-Ej FIRE DEPARTMENT ACCESS DOORS PROVIDED AT <br />INTERVALS LESS THAN 100• SPACING AROUND PERIMETER <br />D MNIMUM CLEAR DOOR OPENING. OF BUILDING <br />32 INCHES (1008.1.1) L 1) 8 9 8 6 <br />D. MAXIMUM DEAD END CORRIDOR \/\l <br />SO FEET (1018.4) <br />FlR <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />KEY NOTES: O <br />1. ACCESSIBLE ENTRANCE/EXIT PER [Be SECTION 1105.1 <br />FF-IR-El <br />FIRE e <br />1- <br />_ _ VEIL DI®. 242'-1T TRA DUST. 772'-4' ®®_TRAVEL DLSL 212'-Y <br />FIRE I t ._ _ �••.f`, _T _t• _':/�J�- ��v '7 `j/Ar�' ��� 0 TRAVEL GIST. 220•-BTRA%EL 015T. 152'-O I IRnvEL D. tst'-� I 1 FIRE <br />Is <br />FIRE <br />I I I I 1 I <br />I 8 y IXIT <br />P <br />1 - - - FIRE <br />m <br />1 I FIRE I I I I I I <br />1 <br />I- <br />1 <br />- FIRE EXIT N <br />p ff�� pp �FA pp <br />FIRST F6m�®� IE��E�71� �L�Atl'd <br />® <br />BETCH CAPITAL <br />8 P S Po L t@ g t S <br />2505 Third Avenue <br />Suite 324 <br />Seattle. WA 98121 <br />206.720.7001 phone <br />206.720.2949 fax <br />uiww.crafta rchi tects.— <br />LPL_ <br />ODKWLTANT <br />)Ost REGIS1ERm <br />_ ARCHR6r <br />stA¢or ' Pst'°�"mx <br />Submittals/Revisions: <br />FOR PERMIT 05/04/16 <br />Sheet Title: GENERAL INFORMATION <br />AND EGRESS PLAN <br />Date: 05/O4/16 <br />Design: <br />Drawn: <br />Project No: <br />15-198 <br />Approved: <br />Building No: <br />Sheet No: <br />T1P1 <br />COPYRIGHT <br />CRAFT ARCHITECTS 2016 <br />