Laserfiche WebLink
1/24/2022 City of Everett Page <br />2:31:32PM <br />INSPECTION ACTIVITY REPORT <br />' �2. <br />Permit No. W0801-013 Site Address 7208 UPPER RIDGE RD <br />Applied 10/30/2007 Applicant Lot <br />Approved Owner TAKHAR SUKHJIVAN & GURDEV Block <br />Issued Contractor OWNER Tract <br />Parent Permit No. AN0710-001 Description CLOSED -CONSULTATION FOR CODE REQUIREMENTS <br />Notes HOW TO ELIMINATE ILLEGAL DUPLEX - THIS ADDRESS HAS QUITE A HISTORY WITH CODE <br />COMPLIANCE <br />(Started as AN record, copied over to W record) <br />1/29/08 attached Complaint Report. <br />Code Compliance Actions report is in file. <br />Requested Scheduled Result <br />Time / By Completed Inspection Type Inspector Remarks Notes <br />10/29/2007 Site Visit TMB Contact Steve Ingalsbe about recording a <br />12/21/2018 See notes re Code Case 05-0510 covenant for the owner -occupied <br />duplex/accessory dwelling status. <br />Permits for existing kitchen required, <br />1/28/2008 Other MEM <none> <br />Application C0801-020 for 2nd kitchen <br />5/20/2008 Site Visit TMB Corr Reqd <br />5/20/2008 Building issues -see notes <br />5/20/2008 Site Visit DXW Corr Reqd <br />5/20/2008 Mechanical issues -see notes <br />5/20/2008 Site Visit DXW Corr Reqd <br />5/20/2008 Plumbing issues -see notes <br />Pre -permit assessment --per discussion with <br />owner <br />Corrections: <br />1. Provide floor plan for review at permit <br />submittal <br />2. Remove wall at bathroom for required <br />water closet clearance and relocate <br />bathroom door <br />3. Abandon two bedrooms for use as <br />sleeping rooms <br />4. Open wall between units (doorway) <br />5. Correct Plumbing, Mechanical, and <br />Electrical issues per attached reports <br />6. Remove gas wall heater or re -install per <br />manufacturer's specifications <br />Corrections: <br />1. 6" smoothe metal duct required for range <br />hood exhaust <br />2. Anti -tip required for range <br />3. Insulation shield required in attic <br />4. For furnace in living room <br />manufacturer's specifications book is <br />required for proper clearance <br />5. Must use B-vent for exhaust on furnace <br />6. Remove furnace in bedroom <br />7. Remove cardboard box in attic over <br />exhaust fan <br />8. Gas pipe to be hard piped into furnace in <br />front room <br />Corrections: <br />1. Licensed Journeyman Plumber to do <br />repairs <br />2. S-traps under sinks <br />3. Check and repair relief line for hotwater <br />tank <br />4. Add siesmic strap to hotwater tank <br />5. Check laundry for P-trap in wall <br />6. Extend plumbing vent on roof <br />7. State all plumbing done without <br />inspection working properly and to Uniform <br />Plumbing Code <br />8. 30" required for water closet <br />INSP_DETAILS <br />C SYSTEMS; <br />